Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Moisture Sensitivity Level (MSL) Termination Max Operating Temperature Min Operating Temperature RoHS Status Published Datasheet Voltage - Rated DC Current Rating Length Height Width Voltage - Rated AC Color Lead Free Factory Lead Time Approval Agency Number of Poles Flammability Rating Reach Compliance Code Actuator Type Illumination Current Rating (Amps) Circuit Protection Type Breaker Type Time to Trip
4230-T120-K0CU-13A 4230-T120-K0CU-13A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail Not Applicable 2016 https://pdf.utmel.com/r/datasheets/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 compliant Lever None 13A Thermal Magnetic
LELBXK1-39259-3-V LELBXK1-39259-3-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download LEL Panel Panel Mount 1 (Unlimited) RoHS Compliant 2014 https://pdf.utmel.com/r/datasheets/sensataairpax-idlbxk13699840-datasheets-4322.pdf 6 Weeks 1 Rocker Magnetic (Hydraulic Delay)
4230-T120-K0BU-40A 4230-T120-K0BU-40A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail Not Applicable 2016 https://pdf.utmel.com/r/datasheets/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 compliant Lever None 40A Thermal Magnetic
127-P10-H-KF-050022-2A 127-P10-H-KF-050022-2A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 127 Panel Panel Mount 1 (Unlimited) ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/eta-127p10hkf05002225a-datasheets-1058.pdf 50V 2A 250V 9 Weeks CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 1 Push to Reset Thermal
2800860 2800860 Phoenix Contact
RFQ

Min: 1

Mult: 1

0 0x0x0 download CB Panel Holder Quick Connect 60°C -30°C RoHS Compliant 2013 /files/phoenixcontact-2800860-datasheets-1106.pdf 50V 3A 52mm 45mm 12.3mm 277V Grey 11 Weeks 1 UL94 V-0 not_compliant Slide Switch Thermal Magnetic
127-P10-H-KF-050022-1A 127-P10-H-KF-050022-1A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 127 Panel Panel Mount 1 (Unlimited) ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/eta-127p10hkf05002225a-datasheets-1058.pdf 48V 1A 240V 9 Weeks CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 1 Push to Reset Thermal
IUGN6-1-51-50.0 IUGN6-1-51-50.0 Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download IUG Panel Mount 1 (Unlimited) RoHS Compliant /files/sensataairpax-ieg617230091v-datasheets-4052.pdf 80V 50A 250V 1 Toggle None 5A MAGNETIC CIRCUIT BREAKER Magnetic (Hydraulic Delay) 1.2 s
IELK1-33341-20-V IELK1-33341-20-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download IEL Panel Panel Mount 1 (Unlimited) RoHS Compliant 2011 https://pdf.utmel.com/r/datasheets/sensataairpax-idlbxk13699840-datasheets-4322.pdf 6 Weeks 1 Lever Magnetic (Hydraulic Delay)
4230-T120-K0BU-7A 4230-T120-K0BU-7A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail Not Applicable 2016 https://pdf.utmel.com/r/datasheets/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 compliant Lever None 7A Thermal Magnetic
IELK1-33341-15-V IELK1-33341-15-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download IEL Panel Panel Mount 1 (Unlimited) RoHS Compliant 2011 https://pdf.utmel.com/r/datasheets/sensataairpax-idlbxk13699840-datasheets-4322.pdf 6 Weeks 1 Lever Magnetic (Hydraulic Delay)
127-P10-H-KF-050022-8A 127-P10-H-KF-050022-8A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 127 Panel Panel Mount 1 (Unlimited) ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/eta-127p10hkf05002225a-datasheets-1058.pdf 50V 8A 250V 9 Weeks CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 1 Push to Reset Thermal
4230-T120-K0DU-16A 4230-T120-K0DU-16A
RFQ

Min: 1

Mult: 1

0 0x0x0
IEL1-1REC4-59-2.50-01-V IEL1-1REC4-59-2.50-01-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download IEL Panel Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-idlbxk13699840-datasheets-4322.pdf 2.5A 6 Weeks 1 Lever 2.5A Magnetic (Hydraulic Delay)
4230-T120-K0DU-13A 4230-T120-K0DU-13A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail Not Applicable 2016 https://pdf.utmel.com/r/datasheets/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 compliant Lever None 13A Thermal Magnetic
127-P10-H-KF-050022-30A 127-P10-H-KF-050022-30A
RFQ

Min: 1

Mult: 1

0 0x0x0
IULR1-1-52-.250-91 IULR1-1-52-.250-91 Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download IULR DIN Rail 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-idlbxk13699840-datasheets-4322.pdf 6 Weeks 1 Lever 250mA Magnetic (Hydraulic Delay)
127-P10-H-KF-050022-10A 127-P10-H-KF-050022-10A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 127 Panel Panel Mount 1 (Unlimited) ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/eta-127p10hkf05002225a-datasheets-1058.pdf 50V 10A 250V 9 Weeks CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 1 Push to Reset Thermal
127-P10-H-KF-050022-20A 127-P10-H-KF-050022-20A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 127 Panel Panel Mount 1 (Unlimited) ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/eta-127p10hkf05002225a-datasheets-1058.pdf 50V 20A 250V 9 Weeks CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 1 Push to Reset Thermal
2800848 2800848 Phoenix Contact
RFQ

Min: 1

Mult: 1

0 0x0x0 download CB Panel Holder Quick Connect 60°C -30°C RoHS Compliant 2012 /files/phoenixcontact-2800848-datasheets-1129.pdf 50V 2A 52mm 45mm 12.3mm 277V Grey Lead Free 7 Weeks CSA, KC, UL, VDE 1 UL94 V-0 unknown Slide Switch THERMAL CIRCUIT BREAKER Thermal Magnetic
127-P10-H-KF-050022-15A 127-P10-H-KF-050022-15A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 127 Panel Panel Mount 1 (Unlimited) ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/eta-127p10hkf05002225a-datasheets-1058.pdf 50V 15A 250V 9 Weeks CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 1 Push to Reset Thermal
4230-T120-K0CU-8A 4230-T120-K0CU-8A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail Not Applicable 2016 https://pdf.utmel.com/r/datasheets/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 compliant Lever None 8A Thermal Magnetic
127-P10-H-KF-050022-3A 127-P10-H-KF-050022-3A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 127 Panel Panel Mount 1 (Unlimited) ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/eta-127p10hkf05002225a-datasheets-1058.pdf 50V 3A 250V 9 Weeks CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 1 Push to Reset Thermal
4230-T120-K0DU-25A 4230-T120-K0DU-25A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail DIN Rail Not Applicable RoHS Compliant 2015 /files/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 Lever None 25A Thermal Magnetic
IELK1-33341-30-V IELK1-33341-30-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download IEL Panel Panel Mount 1 (Unlimited) RoHS Compliant 2011 https://pdf.utmel.com/r/datasheets/sensataairpax-idlbxk13699840-datasheets-4322.pdf 6 Weeks 1 Lever Magnetic (Hydraulic Delay)
4230-T120-K0BU-30A 4230-T120-K0BU-30A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail Not Applicable 2016 https://pdf.utmel.com/r/datasheets/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 compliant Lever None 30A Thermal Magnetic
LMLK1-1RLS4-36856-30-V LMLK1-1RLS4-36856-30-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download LML Panel Panel Mount 1 (Unlimited) RoHS Compliant 2014 https://pdf.utmel.com/r/datasheets/sensataairpax-idlbxk13699840-datasheets-4322.pdf 6 Weeks 1 Lever Magnetic (Hydraulic Delay)
4230-T120-K0DU-3A 4230-T120-K0DU-3A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail Not Applicable 2016 /files/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 compliant Lever None 3A Thermal Magnetic
LEG1-1REC4-61-1.00-01-V LEG1-1REC4-61-1.00-01-V Sensata-Airpax
RFQ

Min: 1

Mult: 1

0 0x0x0 download LEG Panel Mount 1 (Unlimited) RoHS Compliant https://pdf.utmel.com/r/datasheets/sensataairpax-ieg617230091v-datasheets-4052.pdf 6 Weeks 1 Lever 1A Magnetic (Hydraulic Delay)
4230-T120-K0DU-40A 4230-T120-K0DU-40A E-T-A
RFQ

Min: 1

Mult: 1

0 0x0x0 download 4230-T DIN Rail Not Applicable 2016 https://pdf.utmel.com/r/datasheets/eta-x4230ec3-datasheets-6239.pdf 125V 480V 7 Weeks CSA C22.2 No 235, UL489 2 compliant Lever None 40A Thermal Magnetic
N41-B1-24-615-121-F3 N41-B1-24-615-121-F3
RFQ

Min: 1

Mult: 1

0 0x0x0

In Stock