Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Type Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination Voltage - Rated RoHS Status Published Datasheet Current Rating Package / Case Factory Lead Time Ratings REACH SVHC Number of Pins Pbfree Code Connector Type Number of Positions Gender MIL Conformance DIN Conformance IEC Conformance Filter Feature Mixed Contacts Option Number of Contacts Mating Information Contact Gender Empty Shell Backshell Type Coupling Type Housing Color Contact Finish - Mating Orientation ECCN Code Additional Feature Contact Material Contact Plating Total Number of Contacts Body/Shell Style Ingress Protection HTS Code Feature Mounting Feature Military Standard Shielding Body Material Termination Type Body Plating Shell Material Plating Shell Finish Environmental Characteristics Fastening Type Shell Size Material Flammability Rating Contact Shape Contact Type Shell Size - Insert Insert Material Shell Size, MIL Contact Size Note
AFD57-22-41PN-6139 AFD57-22-41PN-6139 TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant Unknown Plug Housing 41 Male 41 Male Olive Drab N (Normal) Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-41 Plastic 16 14 20 27 Contacts Not Included
DTS24W13-8PA-LC DTS24W13-8PA-LC TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-38999 Series III, DTS Bulkhead, Front Side Nut, Panel Panel Mount -65°C~175°C Bulk 1 (Unlimited) Non-RoHS Compliant 2007 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-d3899926fc35sn-datasheets-5785.pdf 12 Weeks Environment Resistant Unknown Receptacle Housing 8 Receptacle 8 Olive Drab A Gold Environment Resistant Shielded Bulkhead - Front Side Nut Shielded Aluminium Cadmium Aluminum Alloy Chromate over Cadmium Threaded Circular Crimp 13-8 Plastic 20 Contacts Not Included
BACC45FN24-57P6H BACC45FN24-57P6H Cinch Connectivity Solutions
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-26500, BACC45 Flanges, Panel Panel Mount -55°C~200°C Bulk 1 (Unlimited) Non-RoHS Compliant 2002 https://pdf.utmel.com/r/datasheets/cinchconnectivitysolutions-dbc25st-datasheets-5874.pdf 12 Weeks Environment Sealed No SVHC Receptacle Housing 57 (Power) Receptacle 57 Black 6 Gold Environment Sealed Flange MIL-DTL-26500 Unshielded Aluminium Aluminum Anodized Bayonet Lock Circular Crimp 24-57 Epoxy, Glass Filled 12 Power 2 20 Power 55 Contacts Not Included
C48-06R22-32S-106 C48-06R22-32S-106 Cinch Connectivity Solutions
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets MIL-DTL-26500, C48 Free Hanging (In-Line) -55°C~200°C Bulk 1 (Unlimited) Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/cinchconnectivitysolutions-dbc25st-datasheets-5874.pdf 12 Weeks 32 Plug Housing 32 (Power) Black N (Normal) IP66 - Dust Tight, Water Resistant Coupling Nut Unshielded Aluminum Anodized Threaded Circular Crimp 22-32 Epoxy, Glass Filled 12 Power 6 20 Power 26 Contacts Not Included
AFD57-22-55SX-6117-LC AFD57-22-55SX-6117-LC TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant No SVHC 55 Plug Housing 55 Female 55 Female Olive Drab X Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included
AFD57-22-55SW-6141 AFD57-22-55SW-6141 TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant Unknown Plug Housing 55 Female 55 Female Olive Drab W Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included
FRCIR06A-18-11P-F80-VO FRCIR06A-18-11P-F80-VO ITT Cannon, LLC
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins CIR Free Hanging (In-Line) -40°C~125°C Bulk Non-RoHS Compliant 2013 https://pdf.utmel.com/r/datasheets/ittcannonllc-cir020r14s2pf80t12-datasheets-7118.pdf 12 Weeks Plug Housing 5 Olive Drab N (Normal) Backshell, Coupling Nut Unshielded Aluminum Alloy Chromate over Cadmium Bayonet Lock Flame Retardant Circular Crimp 18-11 Rubber 12 Contacts Not Included
BACC45FN24-57P8H BACC45FN24-57P8H Cinch Connectivity Solutions
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-26500, BACC45 Panel Mount -55°C~200°C Bulk Not Applicable Non-RoHS Compliant 2002 https://pdf.utmel.com/r/datasheets/cinchconnectivitysolutions-dbc25st-datasheets-5874.pdf 12 Weeks No SVHC Receptacle Housing 57 (Power) Receptacle 57 Black 8 Gold Environment Sealed Flange MIL-DTL-26500 Unshielded Aluminium Aluminum Anodized Bayonet Lock Circular Crimp 24-57 Epoxy, Glass Filled 12 Power 2 20 Power 55 Contacts Not Included
C48-10R24Y57P8-406 C48-10R24Y57P8-406 Cinch Connectivity Solutions
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-26500, C48 Panel Mount -55°C~200°C Bulk Not Applicable Non-RoHS Compliant 2002 https://pdf.utmel.com/r/datasheets/cinchconnectivitysolutions-dbc25st-datasheets-5874.pdf 406 12 Weeks No SVHC Receptacle Housing 57 (Power) Receptacle 57 Black 8 Gold Environment Sealed Flange MIL-DTL-26500 Unshielded Aluminium Aluminum Anodized Bayonet Lock Circular Crimp 24-57 Epoxy, Glass Filled 12 Power 2 20 Power 55 Contacts Not Included
AFD57-22-55SN-6141 AFD57-22-55SN-6141 TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant Unknown Plug Housing 55 Female 55 Female Olive Drab N (Normal) Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included
AFD57-22-55SY-6139 AFD57-22-55SY-6139 TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant Unknown Plug Housing 55 Female 55 Female Olive Drab Y Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included
MS3475W22-41AY MS3475W22-41AY TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins Military, MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) 600V Non-RoHS Compliant 2001 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 12 Weeks Environment Resistant, IP67 Unknown Plug Housing 41 YES NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE Male YES Olive Drab Y COMPATIBLE CONTACTS: M39029/4-110; M39029/4-111 Gold 41 Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Chromate over Cadmium Bayonet Lock Circular Crimp 22-41 Plastic 16 14 20 27 Contacts Not Included
BACC45FN24-57PH BACC45FN24-57PH Cinch Connectivity Solutions
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-26500, BACC45 Flanges, Panel Panel Mount -55°C~200°C Bulk 1 (Unlimited) Non-RoHS Compliant 2002 https://pdf.utmel.com/r/datasheets/cinchconnectivitysolutions-dbc25st-datasheets-5874.pdf 12 Weeks Environment Sealed No SVHC Receptacle Housing 57 (Power) Receptacle 57 Black N (Normal) Gold Environment Sealed Flange MIL-DTL-26500 Unshielded Aluminium Aluminum Anodized Bayonet Lock Circular Crimp 24-57 Epoxy, Glass Filled 12 Power 2 20 Power 55 Contacts Not Included
MS27473T12B3B MS27473T12B3B SOURIAU-SUNBANK
RFQ

Min: 1

Mult: 1

0 0x0x0 download Non-RoHS Compliant 12 Weeks
MS3475W22-55BY MS3475W22-55BY TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets Military, MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) 600V Non-RoHS Compliant 2001 /files/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 12 Weeks Environment Resistant, IP67 Unknown Plug Housing 55 YES NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE Female YES Olive Drab Y Gold 55 Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Chromate over Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included
MS3475W22-41AX MS3475W22-41AX TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins Military, MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) 600V Non-RoHS Compliant 2001 /files/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 12 Weeks Environment Resistant, IP67 Unknown Plug Housing 41 YES NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE Male YES Olive Drab X Gold 41 Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Chromate over Cadmium Bayonet Lock Circular Crimp 22-41 Plastic 16 14 20 27 Contacts Not Included
MS3475W22-41A MS3475W22-41A TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins Military, MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) 600V Non-RoHS Compliant 2001 /files/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 12 Weeks Environment Resistant, IP67 Unknown Plug Housing 41 YES NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE Male YES Olive Drab N (Normal) Gold 41 Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Chromate over Cadmium Bayonet Lock Circular Crimp 22-41 Plastic 16 14 20 27 Contacts Not Included
AFD57-22-41PW-6141 AFD57-22-41PW-6141 TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant Unknown Plug Housing 41 Male 41 Male Olive Drab W Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-41 Plastic 16 14 20 27 Contacts Not Included
AFD57-22-55SW-6117-LC AFD57-22-55SW-6117-LC TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant Unknown Plug Housing 55 Female 55 Female Olive Drab W Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included
MS3475W22-41AW MS3475W22-41AW TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins Military, MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) 600V Non-RoHS Compliant 2001 /files/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 12 Weeks Environment Resistant, IP67 Unknown Plug Housing 41 YES NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE Male YES Olive Drab W Gold 41 Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Chromate over Cadmium Bayonet Lock Circular Crimp 22-41 Plastic 16 14 20 27 Contacts Not Included
MS27466T11B5AB MS27466T11B5AB SOURIAU-SUNBANK
RFQ

Min: 1

Mult: 1

0 0x0x0 download Non-RoHS Compliant 12 Weeks Gold
AFD57-22-41PN-6141 AFD57-22-41PN-6141 TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant Unknown Plug Housing 41 Male 41 Male Olive Drab N (Normal) Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-41 Plastic 16 14 20 27 Contacts Not Included
MS24266R22T32SY-LC MS24266R22T32SY-LC Cinch Connectivity Solutions
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets Military, MIL-DTL-26500 Free Hanging (In-Line) -55°C~200°C Bulk 1 (Unlimited) Non-RoHS Compliant https://pdf.utmel.com/r/datasheets/cinchconnectivitysolutions-dbc25st-datasheets-5874.pdf 12 Weeks 32 Plug Housing 32 (Power) Black Y Environment Sealed Coupling Nut Unshielded Aluminum Anodized Threaded Circular Crimp 22-32 Epoxy, Glass Filled H 12 Power 6 20 Power 26 Contacts Not Included
DTS26W23-35AB DTS26W23-35AB TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins MIL-DTL-38999 Series III, DTS Free Hanging Free Hanging (In-Line) -65°C~175°C Bulk 1 (Unlimited) Non-RoHS Compliant 2007 /files/teconnectivitydeutschconnectors-d3899926fc35sn-datasheets-5785.pdf 12 Weeks Environment Resistant Unknown Plug Housing 100 Male YES NO NO NO GENERAL PURPOSE YES Olive Drab B EAR99 Gold 100 Environment Resistant 8536.69.40.20 Coupling Nut Shielded Aluminium Cadmium Aluminum Alloy Chromate over Cadmium CORROSION/ENVIRONMENT/FLUID RESISTANT Threaded Circular Crimp 23-35 Plastic 22D Contacts Not Included
D38999/26WH35BB D38999/26WH35BB Amphenol Aerospace Operations $80.85
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets Military, MIL-DTL-38999 Series III, Tri-Start™ TV Free Hanging (In-Line) -65°C~175°C Bulk 1 (Unlimited) Non-RoHS Compliant 2006 https://pdf.utmel.com/r/datasheets/amphenolaerospaceoperations-d3899924wa35sn-datasheets-5675.pdf 12 Weeks No SVHC no Plug Housing 100 Male YES NO NO NO GENERAL PURPOSE Female YES Olive Drab NOT SPECIFIED B Copper Gold 100 Environment Resistant Coupling Nut, Self Locking MIL-DTL-38999 Shielded Aluminium Aluminum Cadmium Threaded Circular Crimp 23-35 H 22D Contacts Not Included
8T612B03BN 8T612B03BN SOURIAU-SUNBANK $49.87
RFQ

Min: 1

Mult: 1

0 0x0x0 download CABLE Non-RoHS Compliant 12 Weeks MIL SERIES CONNECTOR YES NO NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE FEMALE YES SOLID BAYONET STANDARD: MIL-DTL-38999, LOW PROFILE 3 PLUG CRIMP ALUMINUM ALLOY CADMIUM PLATED CORROSION/ENVIRONMENT/FLUID RESISTANT 12
KJB0T13W98AC KJB0T13W98AC ITT Cannon, LLC
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Male Pins KJB Flanges, Panel Panel Mount -65°C~175°C Bulk Non-RoHS Compliant 12 Weeks Environment Resistant Receptacle Housing 10 Female Olive Drab C Environment Resistant Flange Unshielded Aluminum Alloy Cadmium over Electroless Nickel Threaded Circular Crimp 13-98 Plastic 20 Contacts Not Included
MS3475W22-55BZ MS3475W22-55BZ TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets Military, MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) 600V Non-RoHS Compliant 2001 /files/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 12 Weeks Environment Resistant, IP67 Unknown Plug Housing 55 YES NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE Female YES Olive Drab Z Gold 55 Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Chromate over Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included
AFD57-22-55SN-6139 AFD57-22-55SN-6139 TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) Crimp 2.3kV Non-RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 7.5A 12 Weeks Environment Resistant Unknown Plug Housing 55 Female 55 Female Olive Drab N (Normal) Gold Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included
MS3475W22-55BX MS3475W22-55BX TE Connectivity Deutsch Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download For Female Sockets Military, MIL-DTL-26482 G Series II, AFD Free Hanging Free Hanging (In-Line) -55°C~175°C Bulk 1 (Unlimited) 600V Non-RoHS Compliant 2001 https://pdf.utmel.com/r/datasheets/teconnectivitydeutschconnectors-ms3471l106pw-datasheets-4045.pdf 12 Weeks Environment Resistant, IP67 Unknown Plug Housing 55 YES NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE Female YES Olive Drab X Gold 55 Environment Resistant Coupling Nut MIL-DTL-26482 Shielded Aluminium Cadmium Aluminum Alloy Nickel Chromate over Cadmium Bayonet Lock Circular Crimp 22-55 Plastic 20 Contacts Not Included

In Stock

Please send RFQ , we will respond immediately.