Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Packaging Moisture Sensitivity Level (MSL) Termination Max Operating Temperature Min Operating Temperature RoHS Status Published Datasheet Length Width Color Lead Free Material Depth Factory Lead Time Weight REACH SVHC Lifecycle Status Pbfree Code Gender ELV Sealable Orientation Flammability Rating ECCN Code Contact Material Contact Plating Housing Material Radiation Hardening HTS Code Wire/Cable Gauge Feature Body Material Insulation Material Terminal and Terminal Block Type Body Plating Number of Rows Wire Gauge Wire Cross Section Wire Gauge (Max) Wire Gauge (Min) Wire/Cable Type Terminal Type Length - Overall Wire/Cable Diameter Terminal Material Insulation Insulation Diameter Mating Tab Width Tab Thickness Plating Insulated Wire Support Contact Finish Width - Tab Length - Tab
EDNF14-187MB-Q EDNF14-187MB-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant Blue 6 Weeks Male Brass Serrated Termination 14-16 AWG Standard 0.790 20.07mm Non-Mating End Insulated 0.165 (4.19mm) 0.032 0.81mm Tin 0.187 4.75mm
6-160526-1 6-160526-1 TE Connectivity AMP Connectors $0.78
RFQ

Min: 1

Mult: 1

0 0x0x0 download Fastin-Faston Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2005 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-51605267-datasheets-1051.pdf 19.2mm 7.45mm 20 Weeks ACTIVE (Last Updated: 4 days ago) yes Female No Straight EAR99 Brass Silver 8536.90.40.00 PUSH-ON TERMINAL 15.5-20 AWG 1.5 mm2 20 AWG 5 AWG Standard 0.756 19.20mm Non-Insulated 0.091 ~ 0.130 (2.31mm ~ 3.30mm) 6.35mm 0.032 0.81mm Yes 0.250 6.35mm 0.305 7.75mm
ED14-188-Q ED14-188-Q Panduit Corp $0.34
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18188l-datasheets-5580.pdf 6 Weeks Female Brass Serrated Termination 14-16 AWG Standard 0.580 14.73mm Non-Insulated 0.020 0.51mm Tin 0.187 4.75mm
182524-2 182524-2 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Fastin-Faston Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp 125°C -40°C RoHS Compliant 1995 15mm 10 Weeks No SVHC ACTIVE (Last Updated: 2 days ago) Female No Straight Bronze Tin No Nylon 14-17 AWG Discrete Standard 0.591 15.00mm 3.81 mm Non-Insulated 0.118 ~ 0.150 (3.00mm ~ 3.81mm) 4.75mm 0.032 0.81mm Tin Yes 0.187 4.75mm 0.197 5.00mm
61107-1 61107-1 TE Connectivity AMP Connectors $0.31
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 1997 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-611071-datasheets-4856.pdf 19.17mm Not Applicable 7.64mm 9 Weeks ACTIVE (Last Updated: 6 days ago) Female Compliant No Straight EAR99 Brass Silver 8536.90.40.00 PUSH-ON TERMINAL 14-18 AWG 18 AWG 14 AWG Discrete Standard 0.755 19.18mm 4.32 mm Non-Insulated 4.318 mm 6.35mm 0.032 0.81mm Yes 0.250 6.35mm 0.305 7.75mm
DV14-187B-M DV14-187B-M Panduit Corp $0.26
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2006 19.05mm 5.84mm Blue 5.8mm 4 Weeks 703.068173g Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam Vinyl PUSH-ON TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.750 19.05mm Non-Mating End Insulated 0.170 (4.32mm) 0.032 0.81mm 0.187 4.75mm
2-165565-1 2-165565-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston, PIDG Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 1997 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-1408052-datasheets-4032.pdf 19.8mm Red Not Applicable 21 Weeks ACTIVE (Last Updated: 4 months ago) Female Compliant No Straight EAR99 Brass Tin 8536.90.40.00 Nylon PUSH-ON TERMINAL 16-22 AWG 1.5 mm2 22 AWG 16 AWG Standard 0.780 19.81mm Non-Mating End Insulated 0.140 (3.56mm) 2.794mm 0.020 0.51mm Yes 0.110 2.79mm 0.248 6.30mm
DPF14-206FIB-3K DPF14-206FIB-3K Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download DiscoGrip™, ReelSmart™ Free Hanging Free Hanging (In-Line) Reel Not Applicable Crimp ROHS3 Compliant 2009 https://pdf.utmel.com/r/datasheets/panduit-dpf14206fib3k-datasheets-5017.pdf 19.812mm Blue 4 Weeks Female EAR99 Brass No 8536.90.40.00 Butted Seam PUSH-ON TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.780 19.81mm Fully Insulated 0.090 ~ 0.160 (2.29mm ~ 4.06mm) 0.020 0.51mm Tin 0.187 4.75mm 0.205 5.21mm
DNF18205FIBX-2K DNF18205FIBX-2K Panduit Corp $0.45
RFQ

Min: 1

Mult: 1

0 0x0x0 download Disco™ Free Hanging Free Hanging (In-Line) Reel Not Applicable Crimp ROHS3 Compliant 2005 https://pdf.utmel.com/r/datasheets/panduitcorp-dnf18250fibx2k-datasheets-9824.pdf 22.098mm Red 7.9mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam PUSH-ON TERMINAL 18-22 AWG 22 AWG 18 AWG Standard 0.870 22.10mm Fully Insulated 0.210 (5.33mm) 0.032 0.81mm 0.187 4.75mm 0.205 5.21mm
7471282 7471282 Würth Elektronik
RFQ

Min: 1

Mult: 1

0 0x0x0 download WA-MTAB Through Hole Bulk Not Applicable Solder ROHS3 Compliant https://pdf.utmel.com/r/datasheets/wrthelektronik-7471282-datasheets-5955.pdf 13 Weeks Male Brass Standard 0.551 14.00mm Non-Insulated 0.032 0.81mm Tin 0.110 2.79mm 0.280 7.11mm
ED14-250-Q ED14-250-Q Panduit Corp $0.28
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18250l-datasheets-5630.pdf 6 Weeks Female Brass 14-16 AWG Standard 0.660 16.76mm Non-Insulated 0.032 0.81mm Tin 0.250 6.35mm
ED14-188-L ED14-188-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18188l-datasheets-5580.pdf 6 Weeks Female Brass Serrated Termination 14-16 AWG Standard 0.580 14.73mm Non-Insulated 0.020 0.51mm Tin 0.187 4.75mm
DV18-250B-MY DV18-250B-MY Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2006 https://pdf.utmel.com/r/datasheets/panduitcorp-dv14206b3k-datasheets-9732.pdf 20.6mm Red 7.4mm 4 Weeks 907.18474g Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam, Serrated Termination Vinyl PUSH-ON TERMINAL 18-22 AWG 22 AWG 18 AWG Standard 0.810 20.57mm Non-Mating End Insulated 0.150 (3.81mm) 0.032 0.81mm 0.250 6.35mm
EDV14-187MB-Q EDV14-187MB-Q Panduit Corp $0.37
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant Blue 6 Weeks Male Brass Serrated Termination 14-16 AWG Standard 0.750 19.05mm Non-Mating End Insulated 0.165 (4.19mm) 0.032 0.81mm Tin 0.187 4.75mm
EDV18-250M-Q EDV18-250M-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv18250ml-datasheets-5665.pdf Red 6 Weeks Male Copper 18-22 AWG Standard 0.980 24.89mm Non-Mating End Insulated 0.154 (3.91mm) 0.032 0.81mm Nickel 0.250 6.35mm
EDV10-250M-Q EDV10-250M-Q Panduit Corp $0.40
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv10250mq-datasheets-5883.pdf Yellow 6 Weeks Male Copper Brazed Seam 10-12 AWG Standard 0.980 24.89mm Non-Mating End Insulated 0.235 (5.97mm) 0.032 0.81mm Nickel 0.250 6.35mm
EDV14-250P-Q EDV14-250P-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv18250pq-datasheets-2495.pdf Blue 6 Weeks Female and Male Brass 14-16 AWG Stacked 0.880 22.35mm Non-Mating End Insulated 0.160 (4.06mm) 0.032 0.81mm Tin 0.250 6.35mm
0190220015 0190220015 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant /files/molex-0190220015-datasheets-5808.pdf 3 Weeks yes Male EAR99 Brass 8536.90.40.00 TAB TERMINAL 10-12 AWG 5 mm2 Standard 0.765 19.43mm Non-Insulated 0.032 0.81mm Zinc 0.250 6.35mm 0.307 7.80mm
696018-2 696018-2 TE Connectivity AMP Connectors $0.74
RFQ

Min: 1

Mult: 1

0 0x0x0 download Faston, PIDG Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 1998 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-6960182-datasheets-5822.pdf 20.32mm Red Not Applicable 13 Weeks ACTIVE (Last Updated: 5 days ago) yes Female Compliant No Straight EAR99 Brass 8536.90.40.00 Nylon WIRE TERMINAL 18-22 AWG 0.96 mm2 22 AWG 18 AWG Standard 0.800 20.32mm Non-Mating End Insulated 0.135 (3.43mm) 5.21mm 0.020 0.51mm Yes Tin 0.205 5.21mm 0.250 6.35mm
EDV14-250M-L EDV14-250M-L Panduit Corp $0.39
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv18250ml-datasheets-5665.pdf Blue 6 Weeks Male Copper 14-16 AWG Standard 0.960 24.38mm Non-Mating End Insulated 0.180 (4.57mm) 0.032 0.81mm Nickel 0.250 6.35mm
3-520338-2 3-520338-2 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Ultra-Fast Free Hanging Free Hanging (In-Line), Right Angle Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2000 /files/teconnectivityampconnectors-35203382-datasheets-5148.pdf 13.081mm Blue Lead Free Brass 13.08mm 7 Weeks Unknown ACTIVE (Last Updated: 3 days ago) Female Compliant No Right Angle UL94 V-2 Brass Tin Nylon No Brass Nylon Tin 1 14-16 AWG 16 AWG 14 AWG Discrete Angled - 90°, Flag 4.699 mm Brass Fully Insulated 0.185 (4.70mm) 4.75mm 0.020 0.51mm Tin Yes Tin 0.187 4.75mm
6-160448-6 6-160448-6 TE Connectivity AMP Connectors $0.45
RFQ

Min: 1

Mult: 1

0 0x0x0 download Fastin-Faston Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2003 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-61604485-datasheets-8907.pdf 19.2mm Not Applicable 7.45mm 10 Weeks ACTIVE (Last Updated: 1 week ago) yes Female Compliant No Straight UL94 V-2 EAR99 Brass Silver 8536.90.40.00 PUSH-ON TERMINAL 13.5-17 AWG 2.5 mm2 17 AWG 5 AWG Standard 0.756 19.20mm Non-Insulated 0.134 ~ 0.201 (3.40mm ~ 5.10mm) 6.35mm 0.032 0.81mm Yes 0.250 6.35mm 0.305 7.75mm
EDV14-250M-Q EDV14-250M-Q Panduit Corp $0.34
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-edv18250ml-datasheets-5665.pdf Blue 6 Weeks Male Copper 14-16 AWG Standard 0.960 24.38mm Non-Mating End Insulated 0.180 (4.57mm) 0.032 0.81mm Nickel 0.250 6.35mm
928909-5 928909-5 TE Connectivity AMP Connectors $0.10
RFQ

Min: 1

Mult: 1

0 0x0x0 download Free Hanging (In-Line) Reel 1 (Unlimited) Crimp RoHS Compliant 2005 22.352mm 17 Weeks ACTIVE (Last Updated: 3 days ago) Female No Straight Phosphor Bronze PUSH-ON TERMINAL Standard 0.878 22.30mm 1.6002 mm Non-Insulated 1.6002 mm 6.35mm 0.032 0.81mm Yes Tin 0.250 6.35mm
94833 94833 3M
RFQ

Min: 1

Mult: 1

0 0x0x0 download Highland™ Free Hanging Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp RoHS Compliant 2002 https://pdf.utmel.com/r/datasheets/3m-94833-datasheets-5855.pdf 24.13mm 6.35mm Yellow Contains Lead 3 Weeks 929.864358g Unknown Female Straight Brass Tin 10 AWG Butted Seam Vinyl 10-12 AWG 12 AWG 10 AWG Standard 0.950 24.13mm Brass Non-Mating End Insulated 0.250 (6.35mm) 0.032 0.81mm Tin 0.250 6.35mm
DV18-206B-MY DV18-206B-MY Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2006 https://pdf.utmel.com/r/datasheets/panduit-dv18206bmy-datasheets-4998.pdf 18.8976mm Red 6.4mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam PUSH-ON TERMINAL 18-22 AWG 22 AWG 18 AWG Standard 0.744 18.90mm Non-Mating End Insulated 0.150 (3.81mm) 0.020 0.51mm 0.187 4.75mm 0.205 5.21mm
DV14-188B-M DV14-188B-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2006 20.066mm 5.84mm Blue 5.8mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam Vinyl PUSH-ON TERMINAL 14-16 AWG 2.5 mm2 16 AWG 14 AWG Standard 0.790 20.06mm Non-Mating End Insulated 0.162 (4.11mm) 0.020 0.51mm 0.187 4.75mm
927852-8 927852-8 TE Connectivity AMP Connectors $0.60
RFQ

Min: 1

Mult: 1

0 0x0x0 download Mark I Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 1997 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-9278521-datasheets-7637.pdf 22.3012mm 10 Weeks ACTIVE (Last Updated: 1 day ago) Female No Straight EAR99 Phosphor Bronze Silver 8536.90.40.00 Bronze PUSH-ON TERMINAL 17-20 AWG 1 mm2 20 AWG 17 AWG Standard 0.878 22.30mm 2.3 mm Non-Insulated 2.3 mm 6.35mm 0.032 0.81mm Yes Tin 0.250 6.35mm
ED18-250-Q ED18-250-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-ed18250l-datasheets-5630.pdf 6 Weeks Female Brass 18-22 AWG Standard 0.660 16.76mm Non-Insulated 0.032 0.81mm Tin 0.250 6.35mm
DV14-205B-M DV14-205B-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2006 18.8976mm 6.35mm Blue 6.4mm 4 Weeks Female EAR99 Brass Tin No 8536.90.40.00 Butted Seam Vinyl PUSH-ON TERMINAL 14-16 AWG 16 AWG 14 AWG Standard 0.744 18.90mm Non-Mating End Insulated 0.170 (4.32mm) 0.032 0.81mm 0.187 4.75mm 0.205 5.21mm

In Stock

Please send RFQ , we will respond immediately.