Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Mounting Type Packaging Moisture Sensitivity Level (MSL) Termination Voltage - Rated RoHS Status Published Datasheet Voltage - Rated DC Diameter Length Width Voltage - Rated AC Color Lead Free Material Depth Factory Lead Time Weight REACH SVHC Lifecycle Status Pbfree Code Gender ELV Thickness Diameter - Inside Orientation ECCN Code Contact Material Contact Plating Radiation Hardening HTS Code Wire/Cable Gauge Feature Body Material Length - Termination Terminal and Terminal Block Type Body Plating Wire Gauge Wire Cross Section Wire Gauge (Max) Wire Gauge (Min) Terminal Type Length - Overall Wire/Cable Diameter Terminal Gender Insulation Insulation Diameter Insulated Wire Support Contact Finish Heavy Duty Stud Diameter Material Thickness Material - Insulation Stud/Tab Size Stud Size Width - Outer Edges Tongue Thickness Tongue Inside Opening Length - Ring Center to Termination
E14-6FB-Q E14-6FB-Q Panduit Corp $0.21
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-e148fbq-datasheets-9412.pdf 6 Weeks Copper Butted Seam 14-16 AWG Standard 0.630 16.00mm Non-Insulated Tin 6 Stud 0.280 7.11mm 0.150 (3.81mm)
53829-2 53829-2 TE Connectivity AMP Connectors $0.29
RFQ

Min: 1

Mult: 1

0 0x0x0 download Plasti-Grip Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2008 https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-538292-datasheets-9672.pdf 18.8976mm 600V White Lead Free 5.16mm 26 Weeks ACTIVE (Last Updated: 6 days ago) Compliant Straight EAR99 Phosphor Bronze Tin 8536.90.40.00 Serrated Termination Bronze 0.405 10.29mm FORK TERMINAL 20-24 AWG 0.65 mm2 24 AWG 20 AWG Spring, Snap 0.744 18.90mm FEMALE Insulated 0.080 ~ 0.125 (2.03mm ~ 3.18mm) Yes No 2.84 mm Poly-Vinyl Chloride (PVC) 4 Stud M2.5 0.203 5.16mm 584.2μm 0.112 (2.84mm) 0.219 5.56mm
2-326859-1 2-326859-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download PIDG Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 2006 /files/teconnectivityampconnectors-326859-datasheets-8298.pdf 300V 27.81046mm 7.92mm 300V Yellow Lead Free 7.92mm 4 Weeks ACTIVE (Last Updated: 2 days ago) Female Compliant Straight EAR99 Copper Tin 8536.90.40.00 Serrated Termination 0.591 15.01mm FORK TERMINAL 10-12 AWG 6.64 mm2 12 AWG 10 AWG Standard 1.095 27.81mm 5.842 mm Insulated 0.150 ~ 0.230 (3.81mm ~ 5.84mm) Yes No 3.68 mm Polyamide (PA), Nylon 6 Stud M3.5 0.312 7.92mm 1.02mm 0.145 (3.68mm) 0.296 7.52mm
MVU18-10FFBK MVU18-10FFBK Artery
RFQ

Min: 1

Mult: 1

0 0x0x0 download Scotchlok™ Free Hanging Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp RoHS Compliant 2000 /files/3m-mvu186ffbk-datasheets-8705.pdf 21.59mm 7.62mm Red 7.62mm 3 Weeks 907.18474g Copper, ETP Tin Butted Seam 0.450 11.43mm 18-22 AWG 22 AWG 18 AWG Flanged 0.850 21.59mm Insulated 0.145 (3.68mm) Tin Vinyl 10 Stud 0.300 7.62mm 0.250 6.35mm
32498 32498 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download PIDG Free Hanging Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp RoHS Compliant 1997 /files/teconnectivityampconnectors-32498-datasheets-9695.pdf 21.08mm 10.57mm 300V Red Not Applicable 10.57mm 15 Weeks ACTIVE (Last Updated: 4 days ago) Female Compliant Straight EAR99 Copper Tin 8536.90.40.00 Serrated Termination 0.404 10.26mm FORK TERMINAL 16-22 AWG 1.65 mm2 22 AWG 16 AWG Flanged 0.830 21.08mm 3.56 mm Insulated 0.105 ~ 0.140 (2.67mm ~ 3.56mm) Yes No 4.17 mm 790μm Polyamide (PA), Nylon 8 Stud M4 0.416 10.57mm 840μm 0.171 (4.34mm) 0.250 6.35mm
0191190032 0191190032 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download InsulKrimp Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0191190032-datasheets-9700.pdf Blue 8 Weeks yes Copper 0.450 11.43mm FORK TERMINAL Flanged 0.850 21.59mm Insulated 0.175 (4.45mm) Electro-Tin 10 Stud 0.301 7.65mm 0.198 (5.03mm) 0.209 5.31mm
P18-6FN-M P18-6FN-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2001 /files/panduitcorp-p186fnm-datasheets-9611.pdf 3.56mm 16mm 6.1mm Red Copper 6.1mm 4 Weeks 657.708937g 1.78 mm Copper Tin No Brazed Seam Copper Tin 16-22 AWG 18 AWG 22 AWG Standard 0.630 16.00mm Non-Insulated Tin 6 Stud 0.240 6.10mm 0.150 (3.81mm)
53242-6 53242-6 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Plasti-Grip Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp 600V RoHS Compliant 2008 /files/teconnectivityampconnectors-532422-datasheets-8138.pdf 24.6126mm 7.47mm Red Not Applicable 7.47mm 7 Weeks ACTIVE (Last Updated: 5 days ago) Compliant EAR99 Brass Tin 8536.90.40.00 Serrated Termination 0.465 11.81mm FORK TERMINAL 16-22 AWG 1.65 mm2 22 AWG 16 AWG Spring, Snap 0.969 24.61mm 5.08 mm FEMALE Insulated 0.150 ~ 0.200 (3.81mm ~ 5.08mm) Yes No 4.826 mm Poly-Vinyl Chloride (PVC) 10 Stud 0.294 7.47mm 790μm 0.190 (4.83mm) 0.281 7.14mm
P18-10F-M P18-10F-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2011 /files/panduitcorp-p186fnm-datasheets-9611.pdf 3.56mm 18.03mm 8.89mm Red Copper 8.89mm 4 Weeks 830.074037g 1.78 mm Copper Tin No Brazed Seam Copper Tin 16-22 AWG 22 AWG 18 AWG Standard 0.710 18.03mm Non-Insulated Tin 10 Stud 0.350 8.89mm 0.200 (5.08mm)
E14-8LFB-Q E14-8LFB-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-e146lfbq-datasheets-9467.pdf 6 Weeks Copper Butted Seam, Serrated Termination 14-16 AWG Spring, Snap 0.770 19.56mm Non-Insulated Tin 8 Stud 0.290 7.37mm 0.170 (4.32mm)
E14-10LFB-L E14-10LFB-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant /files/panduitcorp-e146lfbq-datasheets-9467.pdf 6 Weeks Copper Butted Seam, Serrated Termination 14-16 AWG Spring, Snap 0.770 19.56mm Non-Insulated Tin 10 Stud 0.330 8.38mm 0.200 (5.08mm)
0190980049 0190980049 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant /files/molex-0190980049-datasheets-9719.pdf 5 Weeks Copper 0.179 4.55mm 14-16 AWG Spring, Snap 0.694 17.63mm Non-Insulated Electro-Tin 10 Stud 0.340 8.64mm 0.156 (3.96mm) 0.261 6.63mm
0191410065 0191410065 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant /files/molex-0191410065-datasheets-9620.pdf 7 Weeks yes EAR99 Copper 8536.90.40.00 0.165 4.19mm FORK TERMINAL 14-16 AWG 2 mm2 Standard 0.687 17.45mm Non-Insulated Electro-Tin 10 Stud 0.362 9.19mm 0.198 (5.03mm) 0.269 6.83mm
0191310030 0191310030 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download InsulKrimp Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp ROHS3 Compliant /files/molex-0190540222-datasheets-5673.pdf Red 8 Weeks yes EAR99 Copper 8536.90.40.00 0.405 10.29mm FORK TERMINAL 18-22 AWG 0.8 mm2 Standard 0.785 19.94mm Insulated 0.145 (3.68mm) Electro-Tin Poly-Vinyl Chloride (PVC) 6 Stud 0.245 6.22mm 0.146 (3.71mm) 0.207 5.26mm
0191410063 0191410063 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0191410063-datasheets-9643.pdf 5 Weeks yes EAR99 Copper 8536.90.40.00 0.165 4.19mm FORK TERMINAL 14-16 AWG 2 mm2 Standard 0.687 17.45mm Non-Insulated Electro-Tin 8 Stud 0.362 9.19mm 0.173 (4.39mm) 0.269 6.83mm
E18-8FB-L E18-8FB-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant /files/panduitcorp-e186fbq-datasheets-9473.pdf 6 Weeks Copper Butted Seam 18-22 AWG Standard 0.690 17.53mm Non-Insulated Tin 8 Stud 0.320 8.13mm 0.170 (4.32mm)
E18-8FB-Q E18-8FB-Q Panduit Corp $0.20
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-e186fbq-datasheets-9473.pdf 6 Weeks Copper Butted Seam 18-22 AWG Standard 0.690 17.53mm Non-Insulated Tin 8 Stud 0.320 8.13mm 0.170 (4.32mm)
0191170083 0191170083 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Krimptite Bulk 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0191170083-datasheets-9572.pdf 30 Weeks 14-16 AWG Flanged 6 Stud
E18-8LFB-Q E18-8LFB-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-e188lfbl-datasheets-9507.pdf 6 Weeks Copper Butted Seam 18-22 AWG Spring, Snap 0.740 18.80mm Non-Insulated Tin 8 Stud 0.290 7.37mm 0.160 (4.06mm)
E18-8LFB-L E18-8LFB-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-e188lfbl-datasheets-9507.pdf 6 Weeks Copper Butted Seam 18-22 AWG Spring, Snap 0.740 18.80mm Non-Insulated Tin 8 Stud 0.290 7.37mm 0.160 (4.06mm)
E14-8LFB-L E14-8LFB-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant /files/panduitcorp-e146lfbq-datasheets-9467.pdf 6 Weeks Copper Butted Seam, Serrated Termination 14-16 AWG Spring, Snap 0.770 19.56mm Non-Insulated Tin 8 Stud 0.290 7.37mm 0.170 (4.32mm)
0191640028 0191640028 Molex
RFQ

Min: 1

Mult: 1

0 0x0x0 download Perma-Seal Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant /files/molex-0191640028-datasheets-9510.pdf Blue 4 Weeks yes EAR99 Copper 8536.90.40.00 RING TERMINAL 14-16 AWG 1.94 mm2 Standard 1.420 36.07mm Insulated with Heat Shrink 0.235 (5.97mm) Electro-Tin NiAc 6 Stud 0.370 9.40mm 0.146 (3.71mm)
P14-8F-M P14-8F-M Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Term® Free Hanging Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant 2003 /files/panduitcorp-p148fm-datasheets-9582.pdf 4.06mm 17.526mm 7.87mm Blue 7.87mm 4 Weeks 907.18474g 2.29 mm EAR99 Copper No 8536.90.40.00 Brazed Seam, Serrated Termination FORK TERMINAL 14-18 AWG 16 AWG 14 AWG Standard 0.690 17.53mm Non-Insulated Tin 8 Stud 0.310 7.87mm 0.170 (4.32mm)
BS-21-6S-P BS-21-6S-P 3M $0.33
RFQ

Min: 1

Mult: 1

0 0x0x0 download Free Hanging Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/3m-136-datasheets-8329.pdf 21.082mm Red 6.35mm 3 Weeks 1.000001g Copper, ETP Tin -18 AWG Butted Seam Copper 0.450 11.43mm 18-22 AWG 22 AWG 18 AWG Flanged 0.830 21.08mm Insulated 0.145 (3.68mm) Vinyl 6 Stud 0.250 6.35mm 0.250 6.35mm
E18-6LFB-L E18-6LFB-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/panduitcorp-e188lfbl-datasheets-9507.pdf 6 Weeks Copper Butted Seam 18-22 AWG Spring, Snap 0.680 17.27mm Non-Insulated Tin 6 Stud 0.270 6.86mm 0.150 (3.81mm)
E18-10FB-Q E18-10FB-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant /files/panduitcorp-e186fbq-datasheets-9473.pdf 6 Weeks Copper Butted Seam 18-22 AWG Standard 0.710 18.03mm Non-Insulated Tin 10 Stud 0.350 8.89mm 0.200 (5.08mm)
E18-6FB-L E18-6FB-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant /files/panduitcorp-e186fbq-datasheets-9473.pdf 6 Weeks Copper Butted Seam 18-22 AWG Standard 0.630 16.00mm Non-Insulated Tin 6 Stud 0.300 7.62mm 0.150 (3.81mm)
0191270039 0191270039 Molex $0.54
RFQ

Min: 1

Mult: 1

0 0x0x0 download Avikrimp Free Hanging (In-Line) Bulk 1 (Unlimited) Crimp ROHS3 Compliant https://pdf.utmel.com/r/datasheets/molex-0191270039-datasheets-9524.pdf Blue 9 Weeks Copper 0.400 10.16mm 14-16 AWG Flanged 0.810 20.57mm Insulated 0.165 (4.19mm) Electro-Tin Polyamide (PA), Nylon 6 Stud 0.301 7.65mm 0.146 (3.71mm) 0.209 5.31mm
52943-1 52943-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download PIDG Free Hanging Free Hanging (In-Line) Tape & Reel (TR) 1 (Unlimited) Crimp RoHS Compliant 1999 /files/teconnectivityampconnectors-52943-datasheets-8971.pdf 27.94mm 10.31mm 300V Yellow Lead Free 10.31mm 4 Weeks No SVHC ACTIVE (Last Updated: 2 days ago) yes Female 990μm Straight EAR99 Phosphor Bronze Tin 8536.90.40.00 12 AWG Serrated Termination Bronze 0.601 15.27mm WIRE TERMINAL 10-12 AWG 10 AWG 12 AWG Spring, Snap 1.100 27.94mm 6.35 mm Insulated 0.150 ~ 0.250 (3.81mm ~ 6.35mm) Yes No 4.82 mm Polyamide (PA), Nylon 10 Stud 0.406 10.31mm 990μm 0.190 (4.83mm) 0.276 7.01mm
E18-10LFB-Q E18-10LFB-Q Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download StrongHold™ Free Hanging (In-Line) Bulk Not Applicable Crimp ROHS3 Compliant /files/panduitcorp-e188lfbl-datasheets-9507.pdf 6 Weeks Copper Butted Seam 18-22 AWG Spring, Snap 0.740 18.80mm Non-Insulated Tin 10 Stud 0.330 8.38mm 0.190 (4.83mm)

In Stock

Please send RFQ , we will respond immediately.