Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | RoHS Status | Published | Datasheet | Voltage - Rated DC | Diameter | Length | Width | Voltage - Rated AC | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | Lifecycle Status | Pbfree Code | Gender | ELV | Diameter - Inside | Orientation | ECCN Code | Contact Material | Contact Plating | Radiation Hardening | HTS Code | Feature | Body Material | Length - Termination | Terminal and Terminal Block Type | Body Plating | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Length - Overall | Wire/Cable Diameter | Terminal Gender | Insulation | Insulation Diameter | Insulated Wire Support | Contact Finish | Heavy Duty | Underplate Material | Stud Diameter | Material Thickness | Material - Insulation | Stud/Tab Size | Number of Holes | Stud Size | Width - Outer Edges | Tongue Thickness | Tongue Inside Opening | Length - Ring Center to Termination |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
E14-8LFB-Q | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-e146lfbq-datasheets-9467.pdf | 6 Weeks | Copper | Butted Seam, Serrated Termination | 14-16 AWG | Spring, Snap | 0.770 19.56mm | Non-Insulated | Tin | 8 Stud | 0.290 7.37mm | 0.170 (4.32mm) | |||||||||||||||||||||||||||||||||||||||||||||||
E14-10LFB-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-e146lfbq-datasheets-9467.pdf | 6 Weeks | Copper | Butted Seam, Serrated Termination | 14-16 AWG | Spring, Snap | 0.770 19.56mm | Non-Insulated | Tin | 10 Stud | 0.330 8.38mm | 0.200 (5.08mm) | |||||||||||||||||||||||||||||||||||||||||||||||
0190980049 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Krimptite | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190980049-datasheets-9719.pdf | 5 Weeks | Copper | 0.179 4.55mm | 14-16 AWG | Spring, Snap | 0.694 17.63mm | Non-Insulated | Electro-Tin | 10 Stud | 0.340 8.64mm | 0.156 (3.96mm) | 0.261 6.63mm | ||||||||||||||||||||||||||||||||||||||||||||||
0191410065 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Krimptite | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0191410065-datasheets-9620.pdf | 7 Weeks | yes | EAR99 | Copper | 8536.90.40.00 | 0.165 4.19mm | FORK TERMINAL | 14-16 AWG | 2 mm2 | Standard | 0.687 17.45mm | Non-Insulated | Electro-Tin | 10 Stud | 0.362 9.19mm | 0.198 (5.03mm) | 0.269 6.83mm | |||||||||||||||||||||||||||||||||||||||||
0191310030 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | InsulKrimp | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190540222-datasheets-5673.pdf | Red | 8 Weeks | yes | EAR99 | Copper | 8536.90.40.00 | 0.405 10.29mm | FORK TERMINAL | 18-22 AWG | 0.8 mm2 | Standard | 0.785 19.94mm | Insulated | 0.145 (3.68mm) | Electro-Tin | Poly-Vinyl Chloride (PVC) | 6 Stud | 0.245 6.22mm | 0.146 (3.71mm) | 0.207 5.26mm | ||||||||||||||||||||||||||||||||||||||
0191410063 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Krimptite | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/molex-0191410063-datasheets-9643.pdf | 5 Weeks | yes | EAR99 | Copper | 8536.90.40.00 | 0.165 4.19mm | FORK TERMINAL | 14-16 AWG | 2 mm2 | Standard | 0.687 17.45mm | Non-Insulated | Electro-Tin | 8 Stud | 0.362 9.19mm | 0.173 (4.39mm) | 0.269 6.83mm | |||||||||||||||||||||||||||||||||||||||||
2-321233-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | 105°C | -40°C | RoHS Compliant | 2006 | 300V | 19.13mm | 300V | Blue | Lead Free | 7.54mm | 4 Weeks | ACTIVE (Last Updated: 5 days ago) | yes | Female | Compliant | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | 0.404 10.26mm | WIRE TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.753 19.13mm | 4.32 mm | Insulated | 0.115 ~ 0.170 (2.92mm ~ 4.32mm) | Yes | No | 4.34 mm | Polyamide (PA), Nylon | 8 Stud | M4 | 0.297 7.54mm | 790μm | 0.171 (4.34mm) | 0.203 5.16mm | ||||||||||||||||||
P14-10FN-M | Panduit Corp | $0.16 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2003 | https://pdf.utmel.com/r/datasheets/panduitcorp-p148fm-datasheets-9582.pdf | 4.06mm | 18.03mm | 7.87mm | Blue | 7.87mm | 4 Weeks | 907.18474g | 2.29 mm | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 14-18 AWG | 14 AWG | 16 AWG | Standard | 0.710 18.03mm | Non-Insulated | Tin | 10 Stud | 0.310 7.87mm | 0.200 (5.08mm) | |||||||||||||||||||||||||||||||
P18-8F-M | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduitcorp-p186fnm-datasheets-9611.pdf | 3.56mm | 17.53mm | Red | Copper | 8.13mm | 4 Weeks | 807.394419g | 1.78 mm | Copper | Tin | No | Brazed Seam | Copper | Tin | 16-22 AWG | 18 AWG | 22 AWG | Standard | 0.690 17.53mm | Non-Insulated | Tin | 8 Stud | 0.320 8.13mm | 0.170 (4.32mm) | ||||||||||||||||||||||||||||||||
P14-6F-M | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2003 | /files/panduitcorp-p148fm-datasheets-9582.pdf | 4.06mm | 16mm | 7.11mm | Blue | 7.11mm | 4 Weeks | 807.394419g | 2.29 mm | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 14-18 AWG | 16 AWG | 14 AWG | Standard | 0.630 16.00mm | Non-Insulated | Tin | 6 Stud | 0.280 7.11mm | 0.150 (3.81mm) | ||||||||||||||||||||||||||||||||
P14-10F-M | Panduit Corp | $0.19 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2003 | https://pdf.utmel.com/r/datasheets/panduitcorp-p148fm-datasheets-9582.pdf | 4.06mm | 18.03mm | 8.64mm | Blue | 7.87mm | 4 Weeks | 916.256587g | 2.29 mm | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 14-18 AWG | 16 AWG | 14 AWG | Standard | 0.710 18.03mm | Non-Insulated | Tin | 10 Stud | 0.340 8.64mm | 0.200 (5.08mm) | |||||||||||||||||||||||||||||||
E14-6FB-Q | Panduit Corp | $0.21 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-e148fbq-datasheets-9412.pdf | 6 Weeks | Copper | Butted Seam | 14-16 AWG | Standard | 0.630 16.00mm | Non-Insulated | Tin | 6 Stud | 0.280 7.11mm | 0.150 (3.81mm) | ||||||||||||||||||||||||||||||||||||||||||||||
53829-2 | TE Connectivity AMP Connectors | $0.29 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Free Hanging | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | RoHS Compliant | 2008 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-538292-datasheets-9672.pdf | 18.8976mm | 600V | White | Lead Free | 5.16mm | 26 Weeks | ACTIVE (Last Updated: 6 days ago) | Compliant | Straight | EAR99 | Phosphor Bronze | Tin | 8536.90.40.00 | Serrated Termination | Bronze | 0.405 10.29mm | FORK TERMINAL | 20-24 AWG | 0.65 mm2 | 24 AWG | 20 AWG | Spring, Snap | 0.744 18.90mm | FEMALE | Insulated | 0.080 ~ 0.125 (2.03mm ~ 3.18mm) | Yes | No | 2.84 mm | Poly-Vinyl Chloride (PVC) | 4 Stud | M2.5 | 0.203 5.16mm | 584.2μm | 0.112 (2.84mm) | 0.219 5.56mm | |||||||||||||||||||
2-326859-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Free Hanging | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | RoHS Compliant | 2006 | /files/teconnectivityampconnectors-326859-datasheets-8298.pdf | 300V | 27.81046mm | 7.92mm | 300V | Yellow | Lead Free | 7.92mm | 4 Weeks | ACTIVE (Last Updated: 2 days ago) | Female | Compliant | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | Serrated Termination | 0.591 15.01mm | FORK TERMINAL | 10-12 AWG | 6.64 mm2 | 12 AWG | 10 AWG | Standard | 1.095 27.81mm | 5.842 mm | Insulated | 0.150 ~ 0.230 (3.81mm ~ 5.84mm) | Yes | No | 3.68 mm | Polyamide (PA), Nylon | 6 Stud | M3.5 | 0.312 7.92mm | 1.02mm | 0.145 (3.68mm) | 0.296 7.52mm | ||||||||||||||||||
MVU18-10FFBK | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Free Hanging | Free Hanging (In-Line) | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2000 | /files/3m-mvu186ffbk-datasheets-8705.pdf | 21.59mm | 7.62mm | Red | 7.62mm | 3 Weeks | 907.18474g | Copper, ETP | Tin | Butted Seam | 0.450 11.43mm | 18-22 AWG | 22 AWG | 18 AWG | Flanged | 0.850 21.59mm | Insulated | 0.145 (3.68mm) | Tin | Vinyl | 10 Stud | 0.300 7.62mm | 0.250 6.35mm | ||||||||||||||||||||||||||||||||||
E18-10LFB-Q | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-e188lfbl-datasheets-9507.pdf | 6 Weeks | Copper | Butted Seam | 18-22 AWG | Spring, Snap | 0.740 18.80mm | Non-Insulated | Tin | 10 Stud | 0.330 8.38mm | 0.190 (4.83mm) | |||||||||||||||||||||||||||||||||||||||||||||||
P22-6F-M | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-p226fm-datasheets-9598.pdf | 2.03mm | 14.986mm | 6.35mm | 6.35mm | 4 Weeks | 267.619527g | 1.02 mm | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam | FORK TERMINAL | 22-26 AWG | 22 AWG | 26 AWG | Standard | 0.590 14.99mm | Non-Insulated | 6 Stud | 0.250 6.35mm | 0.150 (3.81mm) | |||||||||||||||||||||||||||||||||
E18-6LFB-Q | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-e188lfbl-datasheets-9507.pdf | 6 Weeks | Copper | Butted Seam | 18-22 AWG | Spring, Snap | 0.680 17.27mm | Non-Insulated | Tin | 6 Stud | 0.270 6.86mm | 0.150 (3.81mm) | |||||||||||||||||||||||||||||||||||||||||||||||
P14-6FN-M | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2003 | /files/panduitcorp-p148fm-datasheets-9582.pdf | 4.06mm | 16mm | 6.1mm | Blue | 6.1mm | 4 Weeks | 762.035182g | 2.29 mm | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 14-18 AWG | 14 AWG | 16 AWG | Standard | 0.630 16.00mm | Non-Insulated | Tin | 6 Stud | 0.240 6.10mm | 0.150 (3.81mm) | ||||||||||||||||||||||||||||||||
0191440016 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | InsulKrimp | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0190540222-datasheets-5673.pdf | Blue | 6 Weeks | yes | Copper | 0.400 10.16mm | FORK TERMINAL | 14-16 AWG | Standard | 0.790 20.07mm | Insulated | 0.175 (4.45mm) | Electro-Tin | Poly-Vinyl Chloride (PVC) | 6 Stud | 0.245 6.22mm | 0.146 (3.71mm) | 0.209 5.31mm | |||||||||||||||||||||||||||||||||||||||||
E18-10FB-L | Panduit Corp | $0.06 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-e186fbq-datasheets-9473.pdf | 6 Weeks | Copper | Butted Seam | 18-22 AWG | Standard | 0.710 18.03mm | Non-Insulated | Tin | 10 Stud | 0.350 8.89mm | 0.200 (5.08mm) | ||||||||||||||||||||||||||||||||||||||||||||||
62795-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Free Hanging | Free Hanging (In-Line) | Tape & Reel (TR) | 1 (Unlimited) | Crimp | RoHS Compliant | 2004 | 20.828mm | Not Applicable | 8.71mm | 9 Weeks | ACTIVE (Last Updated: 6 days ago) | yes | Compliant | 2.03 mm | EAR99 | Brass | Tin | 8536.90.40.00 | FORK TERMINAL | 12-16 AWG | 3 mm2 | 12 AWG | 18 AWG | Spring, Snap | 0.745 18.92mm | Non-Insulated | 0.110 ~ 0.150 (2.79mm ~ 3.81mm) | Yes | No | Nickel | 4.17 mm | 760μm | 8 Stud | 1 | M4 | 0.343 8.71mm | 762μm | 0.171 (4.34mm) | 0.312 7.92mm | |||||||||||||||||||||||||
E14-10FB-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-e148fbq-datasheets-9412.pdf | 6 Weeks | Copper | Butted Seam | 14-16 AWG | Standard | 0.710 18.03mm | Non-Insulated | Tin | 10 Stud | 0.340 8.64mm | 0.200 (5.08mm) | |||||||||||||||||||||||||||||||||||||||||||||||
E14-6LFB-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-e146lfbq-datasheets-9467.pdf | 6 Weeks | Copper | Butted Seam, Serrated Termination | 14-16 AWG | Spring, Snap | 0.700 17.78mm | Non-Insulated | Tin | 6 Stud | 0.250 6.35mm | 0.150 (3.81mm) | |||||||||||||||||||||||||||||||||||||||||||||||
E18-8FB-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-e186fbq-datasheets-9473.pdf | 6 Weeks | Copper | Butted Seam | 18-22 AWG | Standard | 0.690 17.53mm | Non-Insulated | Tin | 8 Stud | 0.320 8.13mm | 0.170 (4.32mm) | |||||||||||||||||||||||||||||||||||||||||||||||
E18-8FB-Q | Panduit Corp | $0.20 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-e186fbq-datasheets-9473.pdf | 6 Weeks | Copper | Butted Seam | 18-22 AWG | Standard | 0.690 17.53mm | Non-Insulated | Tin | 8 Stud | 0.320 8.13mm | 0.170 (4.32mm) | ||||||||||||||||||||||||||||||||||||||||||||||
0191170083 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Krimptite | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/molex-0191170083-datasheets-9572.pdf | 30 Weeks | 14-16 AWG | Flanged | 6 Stud | |||||||||||||||||||||||||||||||||||||||||||||||||||||||
E18-8LFB-Q | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-e188lfbl-datasheets-9507.pdf | 6 Weeks | Copper | Butted Seam | 18-22 AWG | Spring, Snap | 0.740 18.80mm | Non-Insulated | Tin | 8 Stud | 0.290 7.37mm | 0.160 (4.06mm) | |||||||||||||||||||||||||||||||||||||||||||||||
E18-8LFB-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-e188lfbl-datasheets-9507.pdf | 6 Weeks | Copper | Butted Seam | 18-22 AWG | Spring, Snap | 0.740 18.80mm | Non-Insulated | Tin | 8 Stud | 0.290 7.37mm | 0.160 (4.06mm) | |||||||||||||||||||||||||||||||||||||||||||||||
E14-8LFB-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-e146lfbq-datasheets-9467.pdf | 6 Weeks | Copper | Butted Seam, Serrated Termination | 14-16 AWG | Spring, Snap | 0.770 19.56mm | Non-Insulated | Tin | 8 Stud | 0.290 7.37mm | 0.170 (4.32mm) |
Please send RFQ , we will respond immediately.