Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Packaging | Moisture Sensitivity Level (MSL) | Termination | RoHS Status | Published | Datasheet | Package / Case | Length | Operating Supply Voltage | Color | Material | Depth | Factory Lead Time | Weight | Lifecycle Status | Pbfree Code | ELV | Sealable | ECCN Code | Contact Plating | Radiation Hardening | Reach Compliance Code | HTS Code | Wire/Cable Gauge | Feature | Body Material | Terminal and Terminal Block Type | Body Plating | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Terminal Gender | Insulation | Plating | Insulated Wire Support | Heavy Duty | Material Thickness | Government Qualified | Number of Wire Entries |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BSM2-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | RoHS Compliant | 2007 | 15.7mm | 4.1mm | 2 Weeks | 127.005864g | EAR99 | No | 8536.90.40.00 | Brazed Seam | Copper | WIRE TERMINAL | Tin | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||
SCMSX70-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | RoHS Compliant | 2012 | /files/panduitcorp-scms10c-datasheets-7662.pdf | 2 Weeks | 70mm2 | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||
RSC750-X500-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | 117.6mm | Black, Pink | 33.2mm | 4 Weeks | EAR99 | 8536.90.40.00 | Step Up/Step Down | Copper | WIRE TERMINAL | Tin | 750MCM (kcmil) to 500MCM (kcmil) Flex | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||
SCS1000UP-3 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | Non-RoHS Compliant | White | 2 Weeks | compliant | 1000MCM (kcmil) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||
SCMSX16-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | RoHS Compliant | 2012 | /files/panduitcorp-scms10c-datasheets-7662.pdf | 2 Weeks | 16mm2 | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||
RSCX750-4/0-3 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | /files/panduit-rscx750403-datasheets-8809.pdf | 128mm | Yellow, Purple | 38.1mm | 4 Weeks | EAR99 | 8536.90.40.00 | Step Up/Step Down | Copper | WIRE TERMINAL | Tin | 750MCM (kcmil) to 4/0 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||
SAR600-500-2 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | RoHS Compliant | 2001 | Aluminum | 234.95mm | Black | 37.84mm | 4 Weeks | EAR99 | No | 8536.90.40.00 | Cap, Gel Filled, Step Up/Step Down | WIRE TERMINAL | 600MCM (kcmil) to 500MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||
BSMV2BX-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | RoHS Compliant | 2009 | https://pdf.utmel.com/r/datasheets/panduit-bsmv2bxc-datasheets-8810.pdf | 26.6mm | Blue | 4 Weeks | 181.436948g | EAR99 | 8536.90.40.00 | Butted Seam | Copper | WIRE TERMINAL | Tin | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Fully Insulated | 2 | ||||||||||||||||||||||
SCS400UP-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | Non-RoHS Compliant | Blue | 2 Weeks | compliant | 400MCM (kcmil) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||
160631-6 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Amplivar | Cut Tape (CT) | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | /files/teconnectivityampconnectors-1606313-datasheets-3242.pdf | 5.0038mm | 250V | Brass | 2.6mm | 17 Weeks | ACTIVE (Last Updated: 3 days ago) | Compliant | No | Tin | Serrated Mating Area | Brass | Tin | 18-26 AWG | 26 AWG | 18 AWG | Crimpband, Open Band | Non-Insulated | Tin | No | No | 330.2μm | No | Varies by Wire Size | ||||||||||||||||
SCH500-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2000 | 89.66mm | Brown | 26.92mm | 4 Weeks | EAR99 | 8536.90.40.00 | Copper | WIRE TERMINAL | Tin | 500MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||
CTAPF1-12TP-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduit-ctapf112tpc-datasheets-8815.pdf | 46.22mm | Black | 4 Weeks | No | Copper | Tin | 1-12 AWG | 12 AWG | 1 AWG | Crimpband, Open Band | Non-Insulated | Varies by Wire Size | |||||||||||||||||||||||||||
SCH350-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2000 | 72.1mm | Red | 28.6mm | 4 Weeks | EAR99 | 8536.90.40.00 | Nylon | WIRE TERMINAL | 350MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||
JN314-412-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Cable | Bulk | Not Applicable | Crimp | RoHS Compliant | 2011 | 19.812mm | Natural | Nylon | 4 Weeks | 453.59237g | 10-16 AWG | 16 AWG | 10 AWG | Butt Splice, Closed End, Single Opening | Fully Insulated | 1 | ||||||||||||||||||||||||||||
SCH300-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2000 | White | 4 Weeks | EAR99 | 8536.90.40.00 | WIRE TERMINAL | 300MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||||||
280003-2 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Amplivar | Cut Tape (CT) | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/teconnectivityampconnectors-2800032-datasheets-8432.pdf | 8.13mm | 3.94mm | yes | Compliant | EAR99 | No | 8536.90.40.00 | Serrated Mating Area | Brass | WIRE TERMINAL | Tin | 2.5 mm2 | Crimpband, Open Band | FEMALE | Non-Insulated | Varies by Wire Size | |||||||||||||||||||||||
SA4-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | RoHS Compliant | 2011 | /files/panduitcorp-sa6x-datasheets-7848.pdf | Aluminum | 54.1mm | Green | 12.19mm | 1 Weeks | EAR99 | 8536.90.40.00 | 4 AWG | Cap, Gel Filled | Aluminium | WIRE TERMINAL | Tin | 4 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||
RSCKX750-4/0-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/panduit-rsckx750401-datasheets-8802.pdf | Yellow, Purple | 4 Weeks | Step Up/Step Down | 750MCM (kcmil) to 4/0 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||
SCS500UP-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | Non-RoHS Compliant | Brown | 2 Weeks | 500MCM (kcmil) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||
SCS250UP-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | Non-RoHS Compliant | Yellow | 2 Weeks | 250MCM (kcmil) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||
RSCX750-750-3 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | 114.3mm | Yellow, Black | 1.5mm | 4 Weeks | EAR99 | 8536.90.40.00 | Step Up/Step Down | Copper | WIRE TERMINAL | Tin | 750MCM (kcmil) to 750MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||
SAR1/0-2-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | RoHS Compliant | 2001 | 107 | Tan | 4 Weeks | EAR99 | No | 8536.90.40.00 | 2 AWG | Cap, Gel Filled, Step Up/Step Down | WIRE TERMINAL | 1/0 AWG to 2 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||
RSCKX750-750-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | Yellow, Black | 4 Weeks | Step Up/Step Down | 750MCM (kcmil) to 750MCM (kcmil) | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | |||||||||||||||||||||||||||||||||
RSCK4/0-2/0-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/panduit-rsck40201-datasheets-8787.pdf | Black, Purple | 4 Weeks | Step Up/Step Down | 4/0 AWG to 2/0 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||
RSC750-750-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | 117.6mm | Black | 33.2mm | 4 Weeks | EAR99 | 8536.90.40.00 | Step Up/Step Down | Copper | WIRE TERMINAL | Tin | 750MCM (kcmil) to 750MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||
SAR4/0-2/0-5 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | RoHS Compliant | 2001 | Aluminum | 133.09mm | Red | 23.11mm | 4 Weeks | EAR99 | No | 8536.90.40.00 | Cap, Gel Filled, Step Up/Step Down | WIRE TERMINAL | 4/0 AWG to 2/0 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||
SCMSX120-Q | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | RoHS Compliant | 2012 | /files/panduitcorp-scms10c-datasheets-7662.pdf | 2 Weeks | 120mm2 | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||
SCH250-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | 66.8mm | Yellow | 19.55mm | 4 Weeks | EAR99 | 8536.90.40.00 | WIRE TERMINAL | Tin | 250MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||
SCMSX10-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | RoHS Compliant | 2012 | /files/panduitcorp-scms10c-datasheets-7662.pdf | 4 Weeks | 10mm2 | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||
SCMSX185-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | RoHS Compliant | 2012 | /files/panduitcorp-scms10c-datasheets-7662.pdf | 2 Weeks | 185mm2 | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 |