Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | Voltage - Rated | RoHS Status | Published | Datasheet | Package / Case | Length | Operating Supply Voltage | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | Approval Agency | Outside Diameter | Lifecycle Status | Pbfree Code | Connector Type | Gender | MIL Conformance | DIN Conformance | IEC Conformance | Filter Feature | Mixed Contacts | Option | Number of Contacts | Contact Gender | Empty Shell | ELV | Sealable | Diameter - Inside | Contact Finish - Mating | Orientation | ECCN Code | Additional Feature | Contact Material | Contact Plating | Total Number of Contacts | Body/Shell Style | HTS Code | Wire/Cable Gauge | JESD-609 Code | Feature | Reference Standard | Operating Temperature (Min) | Subcategory | Pitch | Body Material | Insulation Material | Connector Support Type | Body Breadth | Terminal and Terminal Block Type | Safety Approval | Body Plating | Number of Rows | Wire Gauge | Number of Decks | Number of Ways | Wire Gauge (Max) | Wire Gauge (Min) | Wire/Cable Type | Terminal Type | Number of Conductors | Mounting Style | Terminal Gender | Insulation | Shell Material | Insulation Diameter | Insulated Wire Support | Reliability | Number Of PCB Rows | PCB Contact Pattern | Contact Style | Mating Contact Pitch | Contact Pattern | Mating Contact Row Spacing | Rated Current (Signal) | Dielectric Withstanding Voltage | Insulator Color | Plating Thickness | UL Flammability Code | Mounting Option 2 | Heavy Duty | Polarization Key | Material Thickness | Government Qualified | Number of Wire Entries |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SCMS150-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduitcorp-scms10c-datasheets-7662.pdf | 57mm | 21mm | 4 Weeks | 716.675945g | EAR99 | 8536.90.40.00 | WIRE TERMINAL | Tin | 150mm2 | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PCSB4-6S-6Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2010 | Clear | 4 Weeks | Female | 6 | Right Angle | EAR99 | 13.46mm | MODULAR TERMINAL BLOCK | UL; CSA | 1 | 4-14 AWG | 1 | 6 | 14 AWG | 4 AWG | Inline, Tap | Fully Insulated | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
BPC1-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Panel | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/panduitcorp-bpc2l-datasheets-7869.pdf | Aluminum | Tan | 4 Weeks | EAR99 | 8536.90.40.00 | 1 AWG | Cap, Gel Filled, Insulating Rubber Sleeve, Pigtail | WIRE TERMINAL | UL | 1 AWG | Bi-Metal Splice, Single End | MALE | Non-Insulated | 1 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11019 | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | 35kV | RoHS Compliant | 2014 | /files/3m-10002-datasheets-6987.pdf | 149.3mm | Black | Copper | 3 Weeks | Copper | Tin | Copper Wire Only | 750MCM (kcmil) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
328569 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Terminyl | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | 52.4764mm | 600V | Red, Yellow | Not Applicable | 20 Weeks | 9.525 mm | ACTIVE (Last Updated: 4 days ago) | Compliant | 6.604 mm | EAR99 | 8536.90.40.00 | Step Up/Step Down | Copper | Nylon | WIRE TERMINAL | Tin | 8 to 10-12 AWG | 10 AWG | 12 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 6.48 mm | Yes | No | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SCH4/0-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduit-sch40x-datasheets-8118.pdf | 64.51mm | Purple | 18.03mm | 4 Weeks | EAR99 | 8536.90.40.00 | WIRE TERMINAL | Tin | 4/0 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0191600172 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | 19160 | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0191600172-datasheets-7340.pdf | Natural | 5 Weeks | 8 AWG | Butt Splice, Closed End, Single Opening | Fully Insulated | Varies by Wire Size | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
53087 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Ampower | BOARD | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2004 | /files/teconnectivityampconnectors-53087-datasheets-7343.pdf | 103.12mm | 16 Weeks | ACTIVE (Last Updated: 1 week ago) | yes | BOARD CONNECTOR | NO | NO | NO | NO | NO | GENERAL PURPOSE | FEMALE | Compliant | No | EAR99 | SIDE BY SIDE STACKABLE | PHOSPHOR BRONZE | Tin | 14 | RECEPTACLE | 8536.69.40.40 | UL | -65°C | Headers and Edge Type Connectors | Copper | GLASS FILLED POLYESTER | 0.199 inch | 2 | 350MCM (kcmil) | Butt Splice, Inline, Individual Openings | ONE | STRAIGHT | Non-Insulated | COMMERCIAL | 2 | RECTANGULAR | BELLOWED TYPE | 0.1 inch | RECTANGULAR | 0.1 inch | 3A | 750VAC V | GREEN | 98μin | 94V-0 | 2 | ||||||||||||||||||||||||||||||||||||||||||||
11011 | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | BOARD/CABLE | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2014 | /files/3m-10002-datasheets-6987.pdf | Red | 3 Weeks | TELECOM AND DATACOM CONNECTOR | NO | NO | NO | NO | NO | GENERAL PURPOSE | MALE | NO | GOLD (8) OVER NICKEL | 3M, POLARIZED, SHROUDED | 10 | PLUG | e4 | Copper Wire Only | 350MCM (kcmil) | Butt Splice, Inline, Individual Openings | STRAIGHT | Non-Insulated | GLASS FILLED LIQUID CRYSTAL POLYMER | 94V-0 | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
324657 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Terminyl | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | /files/teconnectivityampconnectors-324657-datasheets-7346.pdf | 57.8104mm | 600V | Red | Not Applicable | Copper | 17 Weeks | ACTIVE (Last Updated: 3 days ago) | yes | Compliant | 8.636 mm | EAR99 | Tin | 8536.90.40.00 | 8 AWG | Nylon | WIRE TERMINAL | 8 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Fully Insulated | 8.509 mm | Yes | No | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
B-202-82 | TE Connectivity Raychem Cable Protection |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Cable | Bulk | 1 (Unlimited) | Crimp | 125°C | -55°C | Non-RoHS Compliant | 2003 | /files/teconnectivityraychemcableprotection-b20282-datasheets-7349.pdf | 55.88mm | Clear | Not Applicable | 49 Weeks | ACTIVE (Last Updated: 4 months ago) | Non-Compliant | Yes | Polyolefin | Coaxial Cable | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 1.1938 mm | No | No | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SCSF300-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 300 | 65mm | Red | 4 Weeks | EAR99 | 8536.90.40.00 | Copper | WIRE TERMINAL | Tin | 300MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SCL500-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | Brown | 4 Weeks | EAR99 | 8536.90.40.00 | WIRE TERMINAL | 500MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
324659 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Terminyl | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-324659-datasheets-7313.pdf | 63.0936mm | 600V | Blue | Not Applicable | Copper | 14 Weeks | 11.0998 mm | ACTIVE (Last Updated: 4 days ago) | yes | Compliant | 10.668 mm | EAR99 | Tin | 8536.90.40.00 | 6 AWG | Nylon | BULLET TERMINAL | 6 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 10.54 mm | Yes | No | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0191540278 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | InsulKrimp | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0191540278-datasheets-7283.pdf | Blue | 8 Weeks | 14-16 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0192160064 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Multi-Lock | Bulk | 1 (Unlimited) | IDC | ROHS3 Compliant | /files/molex-0192160064-datasheets-7286.pdf | White | 9 Weeks | Hinged Lid | 14-18 AWG | Inline, Tap (Suitcase) | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0191540277 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | InsulKrimp | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0191540277-datasheets-7289.pdf | Red | 8 Weeks | 18-22 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
W-096-03 | TE Connectivity Raychem Cable Protection |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2004 | /files/teconnectivityraychemcableprotection-611954528-datasheets-7181.pdf | 14.6mm | Clear, Yellow Stripe | 7 Weeks | ACTIVE (Last Updated: 3 days ago) | Compliant | Yes | 2.54 mm | Nickel | PTFE | 1900-6755 CMA | Insulated Wire | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | No | No | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
605180-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1.5mm | Copper | 18 Weeks | UL | 22.07 mm | ACTIVE (Last Updated: 4 days ago) | Compliant | Yes | 635 μm | Tin | WIRE AND CABLE | 4/0 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 100μm | No | 102μm | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11007 | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2014 | /files/3m-10002-datasheets-6987.pdf | Orange | 3 Weeks | Copper Wire Only | 3/0 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
MN10BCX-A-BOTTLE | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | /files/3m-ma250dmmfk-datasheets-3277.pdf | Yellow | 3 Weeks | 10-12 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SCH2/0-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduit-sch20x-datasheets-8087.pdf | 57.91mm | Black | 14.73mm | 4 Weeks | EAR99 | 8536.90.40.00 | WIRE TERMINAL | Tin | 2/0 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0192150190 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | VersaKrimp | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0192150190-datasheets-7261.pdf | 9 Weeks | Brazed Seam | 18-22 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
696058-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Ampower | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | /files/teconnectivityampconnectors-6960581-datasheets-7300.pdf | 7 Weeks | Heavy Duty | 450-550MCM (kcmil) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0191600169 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | 19160 | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0191600169-datasheets-7264.pdf | Natural | 5 Weeks | 10-16 AWG | Butt Splice, Closed End, Single Opening | Fully Insulated | Varies by Wire Size | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
52019 | TE Connectivity Aerospace, Defense and Marine |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Copalum | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | /files/teconnectivityaerospacedefenseandmarine-52019-datasheets-7301.pdf | Not Applicable | Copper | 12 Weeks | ACTIVE (Last Updated: 5 days ago) | yes | Compliant | No | EAR99 | Tin | 8536.90.40.00 | Brazed Seam | WIRE TERMINAL | 4/0 AWG (Al), 3/0 AWG (Cu) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
0191640819 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Perma-Seal | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0191640819-datasheets-7267.pdf | Blue | 9 Weeks | 14-16 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
329716 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Strato-Therm | Bulk | Crimp | RoHS Compliant | 2005 | 21.006mm | Natural | Not Applicable | Copper | 17 Weeks | 7.518 mm | ACTIVE (Last Updated: 3 days ago) | Compliant | 4.369 mm | EAR99 | Gold | 8536.90.40.00 | PTFE | WIRE TERMINAL | 8 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 6.477 mm | No | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
324466 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Ampower | BOARD | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1998 | /files/teconnectivityampconnectors-23244662-datasheets-7230.pdf | 2.41mm | Lead Free | Copper | 18 Weeks | 30.5816 mm | ACTIVE (Last Updated: 5 days ago) | BOARD CONNECTOR | Female | Compliant | No | AU | Straight | Tin | 70 | RECEPTACLE | UL, CSA | -65°C | Headers and Edge Type Connectors | 0.38 inch | 2 | 500MCM (kcmil) | Butt Splice, Inline, Individual Openings | ONE | Non-Insulated | COMMERCIAL | 2 | RECTANGULAR | SQ PIN-SKT | 0.1 inch | RECTANGULAR | 0.1 inch | NATURAL | 30μin | THREADED | POLARIZED KEY | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
324454 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Ampower | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2008 | /files/teconnectivityampconnectors-324454-datasheets-7303.pdf | 1.36mm | Lead Free | Copper | 16 Weeks | ACTIVE (Last Updated: 3 days ago) | Female | Compliant | No | EAR99 | Tin | 8536.90.40.00 | WIRE TERMINAL | 800MCM (kcmil) | Inline, Individual Openings (Parallel) | Non-Insulated | 2 |
Please send RFQ , we will respond immediately.