Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Series Mount Packaging Moisture Sensitivity Level (MSL) Termination RoHS Status Published Datasheet Package / Case Length Operating Supply Voltage Color Lead Free Material Depth Factory Lead Time Weight REACH SVHC Lifecycle Status Pbfree Code Gender Number of Contacts ELV Sealable Thickness Orientation ECCN Code Contact Material Contact Plating Radiation Hardening HTS Code Wire/Cable Gauge Feature Pitch Rated Voltage Body Material Terminal and Terminal Block Type Safety Approval Body Plating Number of Rows Wire Gauge Number of Decks Number of Ways Wire Cross Section Wire Gauge (Max) Wire Gauge (Min) Wire/Cable Type Terminal Type Wire/Cable Diameter Terminal Gender Insulation Plating Insulated Wire Support Heavy Duty Material Thickness Government Qualified Number of Wire Entries
SCL1000-3 SCL1000-3 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Cable Bulk Not Applicable Crimp ROHS3 Compliant 2001 /files/panduit-scl10003-datasheets-6759.pdf 4 Weeks EAR99 8536.90.40.00 WIRE TERMINAL 1000MCM (kcmil) Butt Splice, Inline, Individual Openings FEMALE Non-Insulated 2
HTWC250-250-1 HTWC250-250-1 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download H-TAP Cable Bulk Not Applicable Crimp ROHS3 Compliant 2011 /files/panduit-htwc2502501-datasheets-6736.pdf 4 Weeks No Cap (Cover) 250MCM (kcmil)-2 AWG 2 Way Tap Non-Insulated Varies by Wire Size
RSCK4/0-1/0-1 RSCK4/0-1/0-1 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Bulk Not Applicable Crimp ROHS3 Compliant 2008 /files/panduit-rsck40101-datasheets-6761.pdf Purple, Pink 4 Weeks Step Up/Step Down 4/0 AWG to 1/0 AWG Butt Splice, Inline, Individual Openings Fully Insulated Heat Shrink 2
SCT250-250 SCT250-250 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Bulk Not Applicable Crimp ROHS3 Compliant 2007 108mm 60.45mm 4 Weeks EAR99 WIRE TERMINAL Tin 250MCM (kcmil) T-Splice, Tap FEMALE Non-Insulated 3
SCSF2-E SCSF2-E Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Cable Bulk Not Applicable Crimp ROHS3 Compliant 2009 Brown 4 Weeks EAR99 8536.90.40.00 2 AWG WIRE TERMINAL 2 AWG Butt Splice, Inline, Individual Openings FEMALE Non-Insulated 2
RSCK2/0-4-1 RSCK2/0-4-1 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Bulk Not Applicable Crimp ROHS3 Compliant 2008 https://pdf.utmel.com/r/datasheets/panduit-rsck2041-datasheets-6740.pdf Black, Gray 4 Weeks Step Up/Step Down 2/0 AWG to 2-4 AWG 4 AWG 2 AWG Butt Splice, Inline, Individual Openings Fully Insulated Heat Shrink 2
1601587-1 1601587-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download RTM Reel 1 (Unlimited) Crimp RoHS Compliant 2002 3.91mm 250V Not Applicable Brass 9 Weeks ACTIVE (Last Updated: 1 week ago) Compliant No Unplated No Ridged Brass 18.5-21 AWG 21 AWG 5 AWG Discrete Crimpband, Open Band 990.6 μm Non-Insulated Unplated No No 300μm No Varies by Wire Size
MV18BCX-BOTTLE MV18BCX-BOTTLE 3M
RFQ

Min: 1

Mult: 1

0 0x0x0 download Scotchlok™ Bulk 1 (Unlimited) Crimp RoHS Compliant Red 3 Weeks 18-22 AWG Butt Splice, Inline, Individual Openings Fully Insulated 2
1601545-1 1601545-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download RTM Reel 1 (Unlimited) Crimp RoHS Compliant 2002 /files/teconnectivityampconnectors-16015451-datasheets-5677.pdf 1.9304mm 250V Not Applicable Brass 8 Weeks ACTIVE (Last Updated: 2 weeks ago) Compliant No Unplated No Ridged 20-24 AWG 24 AWG 20 AWG Discrete Crimpband, Open Band 840 μm Non-Insulated Unplated No No 406.4μm No Varies by Wire Size
MV14BCX-BOTTLE MV14BCX-BOTTLE Artery
RFQ

Min: 1

Mult: 1

0 0x0x0 download Scotchlok™ Bulk 1 (Unlimited) Crimp RoHS Compliant Blue 3 Weeks 14-16 AWG Butt Splice, Inline, Individual Openings Fully Insulated 2
40864 40864 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download Reel 1 (Unlimited) Crimp RoHS Compliant 2010 /files/teconnectivityampconnectors-40864-datasheets-5679.pdf 3.4036mm 250V 9 Weeks ACTIVE (Last Updated: 3 days ago) yes EAR99 Unplated 8536.90.40.00 WIRE TERMINAL Crimpband, Open Band FEMALE Non-Insulated No 685.8μm Varies by Wire Size
BPC600-6 BPC600-6 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Panel Bulk Not Applicable Crimp ROHS3 Compliant 2008 /files/panduitcorp-bpc2l-datasheets-7869.pdf Aluminum Red 4 Weeks EAR99 8536.90.40.00 Cap, Gel Filled, Insulating Rubber Sleeve, Pigtail WIRE TERMINAL UL 600MCM (kcmil) 387 mm2 Bi-Metal Splice, Single End MALE Non-Insulated 1
1601550-1 1601550-1 TE Connectivity AMP Connectors
RFQ

Min: 1

Mult: 1

0 0x0x0 download RTM Reel 1 (Unlimited) Crimp RoHS Compliant 2002 3.91mm 250V Not Applicable Brass 8 Weeks ACTIVE (Last Updated: 1 week ago) Compliant No Unplated No Ridged 20-24 AWG 24 AWG 20 AWG Discrete Crimpband, Open Band 840 μm Non-Insulated Unplated No No 300μm No Varies by Wire Size
PCSB600-8S-2Y PCSB600-8S-2Y Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download PCSB Cable Bulk Not Applicable Screw ROHS3 Compliant 2013 /files/panduitcorp-pcsb6002s4y-datasheets-8117.pdf Clear 4 Weeks Female 8 Right Angle EAR99 32.51mm 600V MODULAR TERMINAL BLOCK UL; CSA 1 600MCM (kcmil)-6 AWG 1 8 Inline, Tap Fully Insulated
PCSB750-2S-1 PCSB750-2S-1 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download PCSB Bulk Not Applicable Screw ROHS3 Compliant 2005 /files/panduitcorp-pcsb7502s1-datasheets-5682.pdf Clear 4 Weeks 2 Right Angle EAR99 8536.69.40.40 35.05mm 600V STRIP TERMINAL BLOCK UL; CSA 1 700MCM (kcmil)-2 AWG 1 2 Inline, Tap Fully Insulated
RSCK4/0-4-1 RSCK4/0-4-1 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Bulk Not Applicable Crimp ROHS3 Compliant 2008 /files/panduit-rsck4041-datasheets-6746.pdf Purple, Gray 4 Weeks 4 AWG Step Up/Step Down 4/0 AWG to 4 AWG Butt Splice, Inline, Individual Openings Fully Insulated Heat Shrink 2
11542 11542 Master Appliance Corp.
RFQ

Min: 1

Mult: 1

0 0x0x0 download Proseal™ Bulk Not Applicable Crimp /files/masterapplianceco-11545-datasheets-8124.pdf Yellow 2 Weeks 10-12 AWG Butt Splice, Inline, Individual Openings Fully Insulated Heat Shrink 2
PCSB4-8-4Y PCSB4-8-4Y Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download PCSB Cable Bulk Not Applicable Screw ROHS3 Compliant 2012 /files/panduitcorp-pcsb446y-datasheets-8019.pdf Clear 4 Weeks Female 8 Right Angle EAR99 12.44mm 600V MODULAR TERMINAL BLOCK UL 1 4-14 AWG 1 8 14 AWG 4 AWG Inline, Tap Fully Insulated
PCSB350-5-3 PCSB350-5-3 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download PCSB Cable Bulk Not Applicable Screw ROHS3 Compliant 2004 /files/panduitcorp-pcsb35024-datasheets-8113.pdf Clear 4 Weeks Female 5 Right Angle EAR99 25.9mm 600V MODULAR TERMINAL BLOCK UL 1 350MCM (kcmil)-10 AWG 1 5 Inline, Tap Fully Insulated
MU10BCX MU10BCX Artery
RFQ

Min: 1

Mult: 1

0 0x0x0 download Scotchlok™ Box Bulk 1 (Unlimited) Crimp RoHS Compliant 2010 3 Weeks 1.088622kg Unknown Copper Tin 12 AWG 10-12 AWG 12 AWG 10 AWG Butt Splice, Inline, Individual Openings Non-Insulated 2
T/Y+POUCH T/Y+POUCH Artery
RFQ

Min: 1

Mult: 1

0 0x0x0 download Performance Plus™ Bulk Not Applicable Twist On /files/3m-typouch-datasheets-5588.pdf Tan, Yellow 3 Weeks Copper Wire Only, Flame Retardant 12-22 AWG Wire Nut, Wing Fully Insulated Varies by Wire Size
RSC4/0-4-X RSC4/0-4-X Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Bulk Not Applicable Crimp ROHS3 Compliant 2004 79.2mm Purple, Gray 18.03mm 4 Weeks 18mm EAR99 8536.90.40.00 4 AWG Step Up/Step Down Copper WIRE TERMINAL Tin 4/0 AWG to 4 AWG Butt Splice, Inline, Individual Openings Non-Insulated 2
RSC4/0-2/0-X RSC4/0-2/0-X Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Bulk Not Applicable Crimp ROHS3 Compliant 2004 Black, Purple 4 Weeks EAR99 8536.90.40.00 Step Up/Step Down WIRE TERMINAL 4/0 AWG to 2/0 AWG Butt Splice, Inline, Individual Openings FEMALE Non-Insulated 2
SCSF6-L SCSF6-L Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Bulk Not Applicable Crimp ROHS3 Compliant 2011 /files/panduit-scsf6l-datasheets-6704.pdf 44.5mm Blue 4 Weeks 6 AWG Copper Tin 6 AWG Butt Splice, Inline, Individual Openings Non-Insulated 2
HTWC6X-6X-1 HTWC6X-6X-1 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download H-TAP Cable Bulk Not Applicable Crimp ROHS3 Compliant 2011 4 Weeks No Cap (Cover) 6-14 AWG 14 AWG 6 AWG 2 Way Tap Non-Insulated Varies by Wire Size
PCSB600-3S-3Y PCSB600-3S-3Y Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download PCSB Cable Bulk Not Applicable Screw ROHS3 Compliant 2013 /files/panduitcorp-pcsb6002s4y-datasheets-8117.pdf Clear 4 Weeks Female 3 Right Angle EAR99 32.51mm 600V MODULAR TERMINAL BLOCK UL; CSA 1 600MCM (kcmil)-6 AWG 1 3 Inline, Tap Fully Insulated
PCSB250-5S-4Y PCSB250-5S-4Y Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download PCSB Cable Bulk Not Applicable Screw ROHS3 Compliant 2010 /files/panduitcorp-pcsb2502s6y-datasheets-7982.pdf Clear 4 Weeks Female 5 Right Angle EAR99 No 13.46mm 600V MODULAR TERMINAL BLOCK UL; CSA 1 250MCM (kcmil)-10 AWG 1 5 Inline, Tap Fully Insulated
BPC3/0-X BPC3/0-X Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Wire Bulk Not Applicable Crimp ROHS3 Compliant 2008 /files/panduitcorp-bpc2l-datasheets-7869.pdf Aluminum Red 4 Weeks EAR99 8536.90.40.00 Cap, Gel Filled, Insulating Rubber Sleeve, Pigtail UL 3/0 AWG 85.05 mm2 Bi-Metal Splice, Single End MALE Non-Insulated 1
PCSB4-10S-4Y PCSB4-10S-4Y Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download PCSB Cable Bulk Not Applicable Screw ROHS3 Compliant 2010 /files/panduit-pcsb410s4y-datasheets-6734.pdf Clear 4 Weeks Female 10 Right Angle EAR99 No 8536.69.40.40 13.46mm 600V MODULAR TERMINAL BLOCK UL; CSA 1 4-14 AWG 1 10 14 AWG 4 AWG Inline, Tap Fully Insulated
RSCK1/0-4-1 RSCK1/0-4-1 Panduit Corp
RFQ

Min: 1

Mult: 1

0 0x0x0 download Pan-Lug® Bulk Not Applicable Crimp ROHS3 Compliant 2008 Gray, Pink 4 Weeks Step Up/Step Down 1/0 AWG to 2-4 AWG 4 AWG 2 AWG Butt Splice, Inline, Individual Openings Fully Insulated Heat Shrink 2

In Stock

Please send RFQ , we will respond immediately.