Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Packaging | Moisture Sensitivity Level (MSL) | Termination | RoHS Status | Published | Datasheet | Package / Case | Length | Operating Supply Voltage | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | Lifecycle Status | Pbfree Code | Gender | Number of Contacts | ELV | Sealable | Orientation | ECCN Code | Contact Plating | Radiation Hardening | HTS Code | Wire/Cable Gauge | Feature | Pitch | Rated Voltage | Body Material | Terminal and Terminal Block Type | Safety Approval | Body Plating | Number of Rows | Wire Gauge | Number of Decks | Number of Ways | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Wire/Cable Type | Terminal Type | Wire/Cable Diameter | Terminal Gender | Insulation | Plating | Insulated Wire Support | Heavy Duty | Material Thickness | Government Qualified | Number of Wire Entries |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1601587-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | RTM | Reel | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | 3.91mm | 250V | Not Applicable | Brass | 9 Weeks | ACTIVE (Last Updated: 1 week ago) | Compliant | No | Unplated | No | Ridged | Brass | 18.5-21 AWG | 21 AWG | 5 AWG | Discrete | Crimpband, Open Band | 990.6 μm | Non-Insulated | Unplated | No | No | 300μm | No | Varies by Wire Size | ||||||||||||||||||||||||||
MV18BCX-BOTTLE | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | Red | 3 Weeks | 18-22 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||
1601545-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | RTM | Reel | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/teconnectivityampconnectors-16015451-datasheets-5677.pdf | 1.9304mm | 250V | Not Applicable | Brass | 8 Weeks | ACTIVE (Last Updated: 2 weeks ago) | Compliant | No | Unplated | No | Ridged | 20-24 AWG | 24 AWG | 20 AWG | Discrete | Crimpband, Open Band | 840 μm | Non-Insulated | Unplated | No | No | 406.4μm | No | Varies by Wire Size | ||||||||||||||||||||||||||
MV14BCX-BOTTLE | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | Blue | 3 Weeks | 14-16 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||
40864 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Reel | 1 (Unlimited) | Crimp | RoHS Compliant | 2010 | /files/teconnectivityampconnectors-40864-datasheets-5679.pdf | 3.4036mm | 250V | 9 Weeks | ACTIVE (Last Updated: 3 days ago) | yes | EAR99 | Unplated | 8536.90.40.00 | WIRE TERMINAL | Crimpband, Open Band | FEMALE | Non-Insulated | No | 685.8μm | Varies by Wire Size | ||||||||||||||||||||||||||||||||||||
BPC600-6 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Panel | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/panduitcorp-bpc2l-datasheets-7869.pdf | Aluminum | Red | 4 Weeks | EAR99 | 8536.90.40.00 | Cap, Gel Filled, Insulating Rubber Sleeve, Pigtail | WIRE TERMINAL | UL | 600MCM (kcmil) | 387 mm2 | Bi-Metal Splice, Single End | MALE | Non-Insulated | 1 | |||||||||||||||||||||||||||||||||||
1601550-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | RTM | Reel | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | 3.91mm | 250V | Not Applicable | Brass | 8 Weeks | ACTIVE (Last Updated: 1 week ago) | Compliant | No | Unplated | No | Ridged | 20-24 AWG | 24 AWG | 20 AWG | Discrete | Crimpband, Open Band | 840 μm | Non-Insulated | Unplated | No | No | 300μm | No | Varies by Wire Size | |||||||||||||||||||||||||||
PCSB600-8S-2Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2013 | /files/panduitcorp-pcsb6002s4y-datasheets-8117.pdf | Clear | 4 Weeks | Female | 8 | Right Angle | EAR99 | 32.51mm | 600V | MODULAR TERMINAL BLOCK | UL; CSA | 1 | 600MCM (kcmil)-6 AWG | 1 | 8 | Inline, Tap | Fully Insulated | |||||||||||||||||||||||||||||||||
PCSB750-2S-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2005 | /files/panduitcorp-pcsb7502s1-datasheets-5682.pdf | Clear | 4 Weeks | 2 | Right Angle | EAR99 | 8536.69.40.40 | 35.05mm | 600V | STRIP TERMINAL BLOCK | UL; CSA | 1 | 700MCM (kcmil)-2 AWG | 1 | 2 | Inline, Tap | Fully Insulated | ||||||||||||||||||||||||||||||||||
RSCK4/0-4-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/panduit-rsck4041-datasheets-6746.pdf | Purple, Gray | 4 Weeks | 4 AWG | Step Up/Step Down | 4/0 AWG to 4 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||||||||||||
11542 | Master Appliance Corp. |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Proseal™ | Bulk | Not Applicable | Crimp | /files/masterapplianceco-11545-datasheets-8124.pdf | Yellow | 2 Weeks | 10-12 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||||||||||||||||
PCSB600-6S-2Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2013 | https://pdf.utmel.com/r/datasheets/panduitcorp-pcsb6002s4y-datasheets-8117.pdf | Clear | 4 Weeks | Female | 6 | Right Angle | EAR99 | No | 32.51mm | MODULAR TERMINAL BLOCK | UL; CSA | 1 | 600MCM (kcmil)-6 AWG | 1 | 6 | Inline, Tap | Fully Insulated | |||||||||||||||||||||||||||||||||
0192080001 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Krimptite | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0192080001-datasheets-5641.pdf | 4 Weeks | 14-16 AWG | Inline, Individual Openings (Parallel) | Non-Insulated | Varies by Wire Size | ||||||||||||||||||||||||||||||||||||||||||||||
SCT4/0-4/0 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 106.4mm | 58.92mm | 4 Weeks | EAR99 | WIRE TERMINAL | Tin | 4/0 AWG | T-Splice, Tap | FEMALE | Non-Insulated | 3 | ||||||||||||||||||||||||||||||||||||||||
MU14BCHTX-BOTTLE | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | Blue | 3 Weeks | 14-16 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||
SCT2-2 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 98.6mm | 48.76mm | 4 Weeks | EAR99 | 2 AWG | WIRE TERMINAL | Tin | 2 AWG | T-Splice, Tap | FEMALE | Non-Insulated | 3 | |||||||||||||||||||||||||||||||||||||||
SCT2/0-2/0 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 101.6mm | 4 Weeks | EAR99 | WIRE TERMINAL | Tin | 2/0 AWG | T-Splice, Tap | FEMALE | Non-Insulated | 3 | |||||||||||||||||||||||||||||||||||||||||
RSCK1/0-4-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | Gray, Pink | 4 Weeks | Step Up/Step Down | 1/0 AWG to 2-4 AWG | 4 AWG | 2 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||||||||||||
RSCK1/0-6-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | Blue, Pink | 4 Weeks | 45.359237g | Step Up/Step Down | 1/0-6 AWG | 6 AWG | 0 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | |||||||||||||||||||||||||||||||||||||||||
MV10BCX-BOTTLE | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | Yellow | 3 Weeks | 10-12 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||
MH18BCX-BOTTLE | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2000 | /files/3m-mh14bck-datasheets-6974.pdf | Red | 3 Weeks | 18-22 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||||||||||||||
SCSS4-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduit-scss4l-datasheets-6712.pdf | 25.4mm | Gray | 9.65mm | 4 Weeks | EAR99 | 8536.90.40.00 | 4 AWG | WIRE TERMINAL | Tin | 4 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||
RSC2/0-4-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | 73.2mm | Black, Gray | 14.73mm | 4 Weeks | EAR99 | 8536.90.40.00 | Step Up/Step Down | Copper | WIRE TERMINAL | Tin | 2/0 AWG to 2-4 AWG | 4 AWG | 2 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||
HC13-3 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Screw | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2012 | 50.8mm | 20.57mm | 4 Weeks | No | Serrated Mating Area | 2/0-1 AWG | 1 AWG | 0 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||
PCSB250-4S-6Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2011 | /files/panduitcorp-pcsb2502s6y-datasheets-7982.pdf | Clear | 4 Weeks | Female | 4 | Right Angle | EAR99 | 13.46mm | 600V | MODULAR TERMINAL BLOCK | UL; CSA | 1 | 250MCM (kcmil)-10 AWG | 1 | 4 | Inline, Tap | Fully Insulated | |||||||||||||||||||||||||||||||||
SCS250-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2003 | 57.2mm | Yellow | 4 Weeks | EAR99 | 8536.90.40.00 | Copper | WIRE TERMINAL | Tin | 250MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||
PISR500-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2009 | /files/panduit-pisr5001-datasheets-6721.pdf | Aluminum | Clear | 4 Weeks | No | Gel Filled | 500MCM (kcmil)-6 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||
SA400-2 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduitcorp-sa6x-datasheets-7848.pdf | Aluminum | 3.75mm | Green | 1.19mm | 4 Weeks | Cap, Gel Filled | Aluminium | Tin | 400MCM (kcmil) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||
SCSF4/0-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 63.5mm | Yellow | 4 Weeks | EAR99 | 8536.90.40.00 | Copper | WIRE TERMINAL | Tin | 4/0 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||
PCSB4-8-4Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2012 | /files/panduitcorp-pcsb446y-datasheets-8019.pdf | Clear | 4 Weeks | Female | 8 | Right Angle | EAR99 | 12.44mm | 600V | MODULAR TERMINAL BLOCK | UL | 1 | 4-14 AWG | 1 | 8 | 14 AWG | 4 AWG | Inline, Tap | Fully Insulated |
Please send RFQ , we will respond immediately.