| Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Packaging | Moisture Sensitivity Level (MSL) | Termination | RoHS Status | Published | Datasheet | Package / Case | Length | Operating Supply Voltage | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | REACH SVHC | Lifecycle Status | Gender | Number of Contacts | ELV | Sealable | Thickness | Orientation | ECCN Code | Contact Material | Contact Plating | Radiation Hardening | HTS Code | Wire/Cable Gauge | Feature | Pitch | Rated Voltage | Body Material | Terminal and Terminal Block Type | Safety Approval | Body Plating | Number of Rows | Wire Gauge | Number of Decks | Number of Ways | Wire Gauge (Max) | Wire Gauge (Min) | Wire/Cable Type | Terminal Type | Wire/Cable Diameter | Terminal Gender | Insulation | Plating | Insulated Wire Support | Heavy Duty | Material Thickness | Government Qualified | Number of Wire Entries |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 11542 | Master Appliance Corp. |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Proseal™ | Bulk | Not Applicable | Crimp | /files/masterapplianceco-11545-datasheets-8124.pdf | Yellow | 2 Weeks | 10-12 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | |||||||||||||||||||||||||||||||||||||||||||||||
| PCSB600-6S-2Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2013 | https://pdf.utmel.com/r/datasheets/panduitcorp-pcsb6002s4y-datasheets-8117.pdf | Clear | 4 Weeks | Female | 6 | Right Angle | EAR99 | No | 32.51mm | MODULAR TERMINAL BLOCK | UL; CSA | 1 | 600MCM (kcmil)-6 AWG | 1 | 6 | Inline, Tap | Fully Insulated | ||||||||||||||||||||||||||||||||||
| 0192080001 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Krimptite | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0192080001-datasheets-5641.pdf | 4 Weeks | 14-16 AWG | Inline, Individual Openings (Parallel) | Non-Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||||||
| SCT4/0-4/0 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 106.4mm | 58.92mm | 4 Weeks | EAR99 | WIRE TERMINAL | Tin | 4/0 AWG | T-Splice, Tap | FEMALE | Non-Insulated | 3 | |||||||||||||||||||||||||||||||||||||||||
| MU14BCHTX-BOTTLE | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | Blue | 3 Weeks | 14-16 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||
| SCT2-2 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 98.6mm | 48.76mm | 4 Weeks | EAR99 | 2 AWG | WIRE TERMINAL | Tin | 2 AWG | T-Splice, Tap | FEMALE | Non-Insulated | 3 | ||||||||||||||||||||||||||||||||||||||||
| SCT2/0-2/0 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 101.6mm | 4 Weeks | EAR99 | WIRE TERMINAL | Tin | 2/0 AWG | T-Splice, Tap | FEMALE | Non-Insulated | 3 | ||||||||||||||||||||||||||||||||||||||||||
| PCSB350-8-2 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2004 | /files/panduitcorp-pcsb35024-datasheets-8113.pdf | Clear | 4 Weeks | Female | 8 | Right Angle | EAR99 | 25.9mm | 600V | MODULAR TERMINAL BLOCK | UL; CSA | 1 | 350MCM (kcmil)-10 AWG | 1 | 8 | Inline, Tap | Fully Insulated | ||||||||||||||||||||||||||||||||||
| SCL1000-3 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduit-scl10003-datasheets-6759.pdf | 4 Weeks | EAR99 | 8536.90.40.00 | WIRE TERMINAL | 1000MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||
| HTWC250-250-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | H-TAP | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduit-htwc2502501-datasheets-6736.pdf | 4 Weeks | No | Cap (Cover) | 250MCM (kcmil)-2 AWG | 2 Way Tap | Non-Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||
| RSCK4/0-1/0-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/panduit-rsck40101-datasheets-6761.pdf | Purple, Pink | 4 Weeks | Step Up/Step Down | 4/0 AWG to 1/0 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||||||||||||||
| SCT250-250 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2007 | 108mm | 60.45mm | 4 Weeks | EAR99 | WIRE TERMINAL | Tin | 250MCM (kcmil) | T-Splice, Tap | FEMALE | Non-Insulated | 3 | |||||||||||||||||||||||||||||||||||||||||
| SCSF2-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | Brown | 4 Weeks | EAR99 | 8536.90.40.00 | 2 AWG | WIRE TERMINAL | 2 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||
| RSCK2/0-4-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | https://pdf.utmel.com/r/datasheets/panduit-rsck2041-datasheets-6740.pdf | Black, Gray | 4 Weeks | Step Up/Step Down | 2/0 AWG to 2-4 AWG | 4 AWG | 2 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated Heat Shrink | 2 | ||||||||||||||||||||||||||||||||||||||||||
| 1601587-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | RTM | Reel | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | 3.91mm | 250V | Not Applicable | Brass | 9 Weeks | ACTIVE (Last Updated: 1 week ago) | Compliant | No | Unplated | No | Ridged | Brass | 18.5-21 AWG | 21 AWG | 5 AWG | Discrete | Crimpband, Open Band | 990.6 μm | Non-Insulated | Unplated | No | No | 300μm | No | Varies by Wire Size | |||||||||||||||||||||||||||
| MV18BCX-BOTTLE | 3M |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | Red | 3 Weeks | 18-22 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||
| 1601545-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | RTM | Reel | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/teconnectivityampconnectors-16015451-datasheets-5677.pdf | 1.9304mm | 250V | Not Applicable | Brass | 8 Weeks | ACTIVE (Last Updated: 2 weeks ago) | Compliant | No | Unplated | No | Ridged | 20-24 AWG | 24 AWG | 20 AWG | Discrete | Crimpband, Open Band | 840 μm | Non-Insulated | Unplated | No | No | 406.4μm | No | Varies by Wire Size | |||||||||||||||||||||||||||
| SCS250-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2003 | 57.2mm | Yellow | 4 Weeks | EAR99 | 8536.90.40.00 | Copper | WIRE TERMINAL | Tin | 250MCM (kcmil) | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||
| PISR500-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2009 | /files/panduit-pisr5001-datasheets-6721.pdf | Aluminum | Clear | 4 Weeks | No | Gel Filled | 500MCM (kcmil)-6 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||
| SA400-2 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduitcorp-sa6x-datasheets-7848.pdf | Aluminum | 3.75mm | Green | 1.19mm | 4 Weeks | Cap, Gel Filled | Aluminium | Tin | 400MCM (kcmil) | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||
| SCSF4/0-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 63.5mm | Yellow | 4 Weeks | EAR99 | 8536.90.40.00 | Copper | WIRE TERMINAL | Tin | 4/0 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||
| PCSB4-8-4Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2012 | /files/panduitcorp-pcsb446y-datasheets-8019.pdf | Clear | 4 Weeks | Female | 8 | Right Angle | EAR99 | 12.44mm | 600V | MODULAR TERMINAL BLOCK | UL | 1 | 4-14 AWG | 1 | 8 | 14 AWG | 4 AWG | Inline, Tap | Fully Insulated | ||||||||||||||||||||||||||||||||
| PCSB350-5-3 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2004 | /files/panduitcorp-pcsb35024-datasheets-8113.pdf | Clear | 4 Weeks | Female | 5 | Right Angle | EAR99 | 25.9mm | 600V | MODULAR TERMINAL BLOCK | UL | 1 | 350MCM (kcmil)-10 AWG | 1 | 5 | Inline, Tap | Fully Insulated | ||||||||||||||||||||||||||||||||||
| MU10BCX | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Box | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2010 | 3 Weeks | 1.088622kg | Unknown | Copper | Tin | 12 AWG | 10-12 AWG | 12 AWG | 10 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||
| T/Y+POUCH | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Performance Plus™ | Bulk | Not Applicable | Twist On | /files/3m-typouch-datasheets-5588.pdf | Tan, Yellow | 3 Weeks | Copper Wire Only, Flame Retardant | 12-22 AWG | Wire Nut, Wing | Fully Insulated | Varies by Wire Size | ||||||||||||||||||||||||||||||||||||||||||||||
| RSC4/0-4-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | 79.2mm | Purple, Gray | 18.03mm | 4 Weeks | 18mm | EAR99 | 8536.90.40.00 | 4 AWG | Step Up/Step Down | Copper | WIRE TERMINAL | Tin | 4/0 AWG to 4 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||
| RSC4/0-2/0-X | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Lug® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2004 | Black, Purple | 4 Weeks | EAR99 | 8536.90.40.00 | Step Up/Step Down | WIRE TERMINAL | 4/0 AWG to 2/0 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||
| SCSF6-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | /files/panduit-scsf6l-datasheets-6704.pdf | 44.5mm | Blue | 4 Weeks | 6 AWG | Copper | Tin | 6 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||
| HTWC6X-6X-1 | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | H-TAP | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 4 Weeks | No | Cap (Cover) | 6-14 AWG | 14 AWG | 6 AWG | 2 Way Tap | Non-Insulated | Varies by Wire Size | ||||||||||||||||||||||||||||||||||||||||||
| PCSB600-3S-3Y | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PCSB | Cable | Bulk | Not Applicable | Screw | ROHS3 Compliant | 2013 | /files/panduitcorp-pcsb6002s4y-datasheets-8117.pdf | Clear | 4 Weeks | Female | 3 | Right Angle | EAR99 | 32.51mm | 600V | MODULAR TERMINAL BLOCK | UL; CSA | 1 | 600MCM (kcmil)-6 AWG | 1 | 3 | Inline, Tap | Fully Insulated |
Please send RFQ , we will respond immediately.