Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Packaging | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | Voltage - Rated | RoHS Status | Published | Datasheet | Diameter | Package / Case | Length | Operating Supply Voltage | Color | Lead Free | Material | Depth | Factory Lead Time | Weight | REACH SVHC | Outside Diameter | Lifecycle Status | Pbfree Code | Gender | ELV | Sealable | Thickness | Diameter - Inside | Orientation | ECCN Code | Contact Material | Contact Plating | Radiation Hardening | HTS Code | Wire/Cable Gauge | Feature | Body Material | Insulation Material | Terminal and Terminal Block Type | Body Plating | Wire Gauge | Wire Gauge (Max) | Wire Gauge (Min) | Wire/Cable Type | Terminal Type | Wire/Cable Diameter | Terminal Gender | Insulation | Insulation Diameter | Plating | Insulated Wire Support | Plating Thickness | Heavy Duty | Material Thickness | Government Qualified | Number of Wire Entries |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ESV10-ESV14-Q | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-ev108rbq-datasheets-8533.pdf | Yellow, Blue Stripe | 6 Weeks | Step Up/Step Down | 10-12 to 14-16 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||
0192150047 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | VersaKrimp | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0192150047-datasheets-3764.pdf | 4 Weeks | Brazed Seam | 1/0 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||
34137-3 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Bulk | 1 (Unlimited) | Crimp | Non-RoHS Compliant | 2009 | 7.6454mm | Copper | 12 Weeks | 4.191 mm | ACTIVE (Last Updated: 4 days ago) | Non-Compliant | 2.159 mm | EAR99 | Lead, Tin | 8536.90.40.00 | Brazed Seam, Serrated Mating Area | WIRE TERMINAL | 14-16 AWG | Inline, Individual Openings (Parallel) | Non-Insulated | Lead, Tin | No | 840μm | 2 | ||||||||||||||||||||||||||||||||||||
SG-B BAG | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Twist On | RoHS Compliant | /files/3m-sgbpouch-datasheets-7608.pdf | Blue | 4 Weeks | Copper Wire Only | 6-14 AWG | Wire Nut, Wing | Fully Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||||||||
0192060005 | Molex |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | InsulKrimp | Bulk | 1 (Unlimited) | Crimp | ROHS3 Compliant | /files/molex-0192060005-datasheets-3689.pdf | Blue | 9 Weeks | 14-16 AWG | Inline, Individual Openings (Parallel) | Fully Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||||||||
55808-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Crimp | 600V | RoHS Compliant | 2004 | /files/teconnectivityampconnectors-558081-datasheets-3696.pdf | 31.08mm | Black | Lead Free | 17 Weeks | ACTIVE (Last Updated: 3 days ago) | Female | Compliant | Straight | EAR99 | 8536.90.40.00 | -8 AWG | Copper | PVC | WIRE TERMINAL | Tin | 8-18 AWG | 18 AWG | 8 AWG | Butt Splice, Closed End, Single Opening | Fully Insulated | 12.7 mm | No | 1 | |||||||||||||||||||||||||||||||
JN314-412-M | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 19.812mm | Natural | Nylon | 4 Weeks | 2.267962kg | No | Nylon | 10-16 AWG | 16 AWG | 10 AWG | Butt Splice, Closed End, Single Opening | Fully Insulated | 1 | |||||||||||||||||||||||||||||||||||||||||
BSH10-E | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | 110°C | -55°C | 600V | ROHS3 Compliant | 2008 | /files/panduitcorp-bsh14d-datasheets-6887.pdf | 18.8mm | Yellow | PO, Polyolefin | 4 Weeks | 79.832257g | Female | Straight | EAR99 | No | 8536.90.40.00 | Brazed Seam | Copper | Polyolefin | WIRE TERMINAL | Tin | 10-12 AWG | 12 AWG | 10 AWG | Butt Splice, Inline, Individual Openings | 4 mm | Fully Insulated Heat Shrink | 2 | |||||||||||||||||||||||||||||
567-BOX | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Box | Bulk | 1 (Unlimited) | IDC | 600V | RoHS Compliant | 2005 | /files/3m-567bin-datasheets-2344.pdf | 4.8mm | 100 | 21.1mm | Brown | 3 Weeks | 3.810176kg | 800μm | Brass | Tin | 14 AWG | Flame Retardant, Hinged Lid(s) | PP | 14-18 AWG | 18 AWG | 14 AWG | Inline, Tap (Suitcase) | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||
34138-3 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Solistrand | Bulk | 1 (Unlimited) | Crimp | Non-RoHS Compliant | 2009 | /files/teconnectivityampconnectors-8341382-datasheets-7074.pdf | 8.712mm | Copper | 13 Weeks | ACTIVE (Last Updated: 4 days ago) | no | Non-Compliant | 3.28 mm | EAR99 | Tin | No | 8536.90.40.00 | Brazed Seam, Serrated Mating Area | WIRE TERMINAL | 10-12 AWG | Inline, Individual Openings (Parallel) | Non-Insulated | Lead, Tin | 978μm | 2 | |||||||||||||||||||||||||||||||||||
35244 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | https://pdf.utmel.com/r/datasheets/teconnectivityampconnectors-2352441-datasheets-7673.pdf | 26.16mm | Blue | Not Applicable | 13 Weeks | Unknown | ACTIVE (Last Updated: 5 days ago) | yes | Female | Compliant | Straight | EAR99 | 8536.90.40.00 | Serrated Mating Area | Copper | Vinyl | WIRE TERMINAL | Tin | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 5.46 mm | No | 2 | |||||||||||||||||||||||||||||
55793-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 1997 | /files/teconnectivityampconnectors-557932-datasheets-3631.pdf | 29.464mm | Transparent, Yellow Stripe | Not Applicable | Copper | 17 Weeks | ACTIVE (Last Updated: 1 week ago) | yes | Compliant | EAR99 | Tin | 8536.90.40.00 | WIRE TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Fully Insulated | 5.842 mm | No | 2 | |||||||||||||||||||||||||||||||||
680104-000 | TE Connectivity Aerospace, Defense and Marine |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | MiniSeal | Bulk | 1 (Unlimited) | Crimp | Non-RoHS Compliant | 2004 | /files/teconnectivity-680104000-datasheets-6037.pdf | 300 | 7.112mm | Red | 2.03mm | 7 Weeks | ACTIVE (Last Updated: 5 days ago) | 1.2 mm | No | Tin | 300-1510 CMA | 1510 AWG | 300 AWG | Insulated Wire | Butt Splice, Inline, Individual Openings | Non-Insulated | No | No | 2 | ||||||||||||||||||||||||||||||||||||
2213600-7 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | CoolSplice | Bulk | Not Applicable | IDC | RoHS Compliant | /files/teconnectivityampconnectors-22136005-datasheets-7396.pdf | Translucent - Yellow | 22 Weeks | 12-14 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||
EQSP10-18D-Q | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Bulk | Not Applicable | IDC | ROHS3 Compliant | /files/panduitcorp-ev108rbq-datasheets-8533.pdf | Brown | 6 Weeks | Hinged Lid | 10-18 AWG | Inline, Tap (Suitcase) | Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||||||
5-1377173-2 | TE Connectivity AMP Connectors | $0.30 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2013 | /files/teconnectivityampconnectors-13771734-datasheets-9158.pdf | 27.3304mm | Red | Copper | 17 Weeks | ACTIVE (Last Updated: 5 days ago) | Compliant | EAR99 | 8536.90.40.00 | Serrated Mating Area | RING TERMINAL | 16-22 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | Tin | 2.54μm | No | 790μm | 2 | |||||||||||||||||||||||||||||||||||
MVU18BCX | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Scotchlok™ | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2002 | /files/3m-mvu14bck-datasheets-7045.pdf | 100 | 25.4mm | Red | 3 Weeks | 725.747792g | Copper | Tin | 18 AWG | Vinyl | 18-22 AWG | 22 AWG | 18 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||
JN314-412-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Wire | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2008 | /files/panduit-jn314412c-datasheets-6075.pdf | 20.066mm | Natural | 4 Weeks | 240.403984g | Female | Straight | EAR99 | No | 8536.90.40.00 | Brass | Nylon | Tin | 10-16 AWG | 12 AWG | 14 AWG | Butt Splice, Closed End, Single Opening | Fully Insulated | 1 | |||||||||||||||||||||||||||||||||||
2324697-6 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Push Grip | Bulk | 1 (Unlimited) | Push In | /files/teconnectivityampconnectors-23246972-datasheets-3440.pdf | Purple | 15 Weeks | 12-22 AWG | Butt Splice, Closed End, Individual Openings | Fully Insulated | 6 | ||||||||||||||||||||||||||||||||||||||||||||||||||
CTAPF4-12-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | 38.1mm | Brown | Copper | 4 Weeks | 1.242843kg | 12 AWG | 6-12 AWG | 8 AWG | 12 AWG | Crimpband, Open Band | Non-Insulated | Varies by Wire Size | |||||||||||||||||||||||||||||||||||||||||||
BSV14X-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Pan-Term® | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | 26.4mm | Blue | 4 Weeks | No SVHC | Straight | EAR99 | Copper | Tin | 8536.90.40.00 | 16 AWG | Brazed Seam | Vinyl | WIRE TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||
ESV10-ESV18-Q | Panduit Corp | $2.64 |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-ev108rbq-datasheets-8533.pdf | Yellow, Red Stripe | 6 Weeks | Step Up/Step Down | 10-12 to 18-22 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||
CTAPF8-12-C | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Cable | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | Blue | 4 Weeks | No | 8-12 AWG | 12 AWG | 8 AWG | Crimpband, Open Band | Non-Insulated | Varies by Wire Size | ||||||||||||||||||||||||||||||||||||||||||||||
ES14B-L | Panduit Corp |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | StrongHold™ | Bulk | Not Applicable | Crimp | ROHS3 Compliant | /files/panduitcorp-es18bl-datasheets-7605.pdf | 6 Weeks | Butted Seam, Serrated Mating Area | 14-16 AWG | Butt Splice, Inline, Individual Openings | Non-Insulated | 2 | |||||||||||||||||||||||||||||||||||||||||||||||||
696010-2 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Tape & Reel (TR) | 1 (Unlimited) | Crimp | 302°C | 149°C | RoHS Compliant | 2016 | /files/teconnectivityampconnectors-6960102-datasheets-3610.pdf | 687.07mm | 600V | Transparent, Blue Stripe | Copper | 20 Weeks | 4.191 mm | ACTIVE (Last Updated: 4 days ago) | yes | Compliant | 85 μm | EAR99 | Tin | 8536.90.40.00 | Serrated Mating Area, Step Up/Step Down | Vinyl | WIRE TERMINAL | 14-16 to 18-22 AWG | 18 AWG | 22 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Fully Insulated | 170 μm | Yes | 100μm | No | 31μm | 2 | ||||||||||||||||||||||||
61-SN-A | Artery |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Bulk | 1 (Unlimited) | Crimp | RoHS Compliant | 2005 | 27.432mm | Red | 3 Weeks | 1.000001g | -18 AWG | Nylon | 18-22 AWG | 22 AWG | 18 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2 | ||||||||||||||||||||||||||||||||||||||||||||
2-320570-3 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Tape & Reel (TR) | 1 (Unlimited) | Crimp | RoHS Compliant | 2006 | Yellow | Not Applicable | Copper | 27 Weeks | ACTIVE (Last Updated: 1 week ago) | Compliant | No | EAR99 | Tin | 8536.90.40.00 | Serrated Mating Area | WIRE TERMINAL | 10-12 AWG | 12 AWG | 10 AWG | Butt Splice, Inline, Individual Openings | FEMALE | Fully Insulated | 5.588 mm | 2 | |||||||||||||||||||||||||||||||||||
2324697-3 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Push Grip | Bulk | 1 (Unlimited) | Push In | /files/teconnectivityampconnectors-23246972-datasheets-3440.pdf | Orange | 15 Weeks | 12-22 AWG | Butt Splice, Closed End, Individual Openings | Fully Insulated | 3 | ||||||||||||||||||||||||||||||||||||||||||||||||||
2-320562-3 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | PIDG | Tape & Reel (TR) | 1 (Unlimited) | Crimp | RoHS Compliant | 2005 | /files/teconnectivityampconnectors-83205622-datasheets-7196.pdf | 32.13mm | Blue | Not Applicable | 7 Weeks | ACTIVE (Last Updated: 1 day ago) | Female | Compliant | No | Straight | EAR99 | 8536.90.40.00 | Serrated Mating Area | Copper | Nylon | WIRE TERMINAL | Tin | 14-16 AWG | 16 AWG | 14 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 3.81 mm | Yes | 2 | ||||||||||||||||||||||||||||||
2-321026-1 | TE Connectivity AMP Connectors |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Plasti-Grip | Tape & Reel (TR) | 1 (Unlimited) | Crimp | RoHS Compliant | 2006 | /files/teconnectivityampconnectors-83210261-datasheets-7117.pdf | 15.748mm | Yellow | Not Applicable | Copper | 15 Weeks | ACTIVE (Last Updated: 5 days ago) | yes | Compliant | EAR99 | Tin | 8536.90.40.00 | Serrated Mating Area | WIRE TERMINAL | 22-26 AWG | 26 AWG | 22 AWG | Butt Splice, Inline, Individual Openings | Fully Insulated | 2.03 mm | No | 2 |
Please send RFQ , we will respond immediately.