Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Type | Series | Mount | Mounting Type | Operating Temperature | Packaging | Moisture Sensitivity Level (MSL) | Termination | Max Operating Temperature | Min Operating Temperature | RoHS Status | Published | Datasheet | Capacitance | Length | Voltage - Rated AC | Lead Free | Factory Lead Time | REACH SVHC | Resistance | Reach Compliance Code | Power Rating | Contact Resistance | Termination Style | Circuit | Throw Configuration | Contact Current Rating | Operate Time | Release Time | Power - Rated | Size - Body | Current - Switching | Operate Range | Current - Carry | Voltage - Switching AC | Length - Overall | Voltage - Switching DC |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DRR-DTH-95-100 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | 2011 | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | Lead Free | Axial | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 95 ~ 100AT | 3A DC | 350V | 3.375 85.73mm | 500V | |||||||||||||||||
MARR-5-17-28 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | MARR-5 | Axial, Through Hole | Through Hole | -75°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | 2005 | /files/littelfuseinc-marr52228-datasheets-5134.pdf | 0.2pF | 56.769mm | 1kV | Lead Free | unknown | 10W | Axial | SPST-NO | SPST | 0.75ms | 0.3ms | 0.105Diax0.775L 2.66mmx19.69mm | 350mA AC 500mA DC | 17 ~ 28AT | 1.3A DC | 265V | 2.235 56.77mm | 1000V | ||||||||||||
DRT-DTH-60-70 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Axial, Through Hole | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -20°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | 85.725mm | 500V | Lead Free | 50W | Axial | SPDT | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 60 ~ 70AT | 2A DC | 350V | 3.375 85.73mm | 500V | |||||||||
MARR-5-27-43 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | MARR-5 | Axial | Through Hole | -75°C~125°C | Bulk | 1 (Unlimited) | Axial | ROHS3 Compliant | /files/littelfuseinc-marr52228-datasheets-5134.pdf | 0.2pF | Lead Free | Axial | SPST-NO | SPST | 0.75ms | 0.3ms | 10W | 0.105Diax0.775L 2.66mmx19.69mm | 350mA AC 500mA DC | 27 ~ 43AT | 1.3A DC | 265V | 2.235 56.77mm | 1000V | |||||||||||||||
DRR-DTH-60-80 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Axial, Through Hole | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -20°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | 85.725mm | 500V | Lead Free | 11 Weeks | 30W | Axial | SPDT | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 60 ~ 80AT | 3A DC | 350V | 3.375 85.73mm | 500V | ||||||||
DRR-DTH-90-95 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | Lead Free | Axial | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 90 ~ 95AT | 3A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
DRR-DTH-75-85 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Axial | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | ROHS3 Compliant | 2011 | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | Lead Free | Axial | SPDT | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 75 ~ 85AT | 3A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||
MDCG-4-7-18 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | MDCG-4 | Through Hole | -40°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-mdcg41218-datasheets-1818.pdf | 0.2pF | Lead Free | Axial | SPST-NO | 0.6ms | 0.2ms | 10W | 0.090Diax0.600L 2.28mmx15.24mm | 350mA AC 500mA DC | 7 ~ 18AT | 1.2A DC | 140V | 1.590 40.39mm | 200V | ||||||||||||||||||
DRR-DTH-55-60 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Axial, Through Hole | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -20°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | 85.725mm | 500V | Lead Free | 30W | Axial | SPDT | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 55 ~ 60AT | 3A DC | 350V | 3.375 85.73mm | 500V | |||||||||
MARR-5-22-43 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | MARR-5 | Axial | Through Hole | -75°C~125°C | Bulk | 1 (Unlimited) | Axial | ROHS3 Compliant | /files/littelfuseinc-marr52228-datasheets-5134.pdf | 0.2pF | Lead Free | Axial | SPST-NO | SPST | 0.75ms | 0.3ms | 10W | 0.105Diax0.775L 2.66mmx19.69mm | 350mA AC 500mA DC | 22 ~ 43AT | 1.3A DC | 265V | 2.235 56.77mm | 1000V | |||||||||||||||
DRT-DTH-50-60 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Axial, Through Hole | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -20°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | 85.725mm | 500V | Lead Free | 11 Weeks | 50W | Axial | SPDT | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 50 ~ 60AT | 2A DC | 350V | 3.375 85.73mm | 500V | ||||||||
MARR-5-42-53 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | MARR-5 | Through Hole | -75°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-marr52228-datasheets-5134.pdf | 0.2pF | Lead Free | Axial | SPST-NO | 0.75ms | 0.3ms | 10W | 0.105Diax0.775L 2.66mmx19.69mm | 350mA AC 500mA DC | 42 ~ 53AT | 1.3A DC | 265V | 2.235 56.77mm | 1000V | ||||||||||||||||||
DRR-DTH-85-100 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | Lead Free | Axial | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 85 ~ 100AT | 3A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
MARR-5-37-48 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | MARR-5 | Through Hole | -75°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-marr52228-datasheets-5134.pdf | 0.2pF | Lead Free | Axial | SPST-NO | 0.75ms | 0.3ms | 10W | 0.105Diax0.775L 2.66mmx19.69mm | 350mA AC 500mA DC | 37 ~ 48AT | 1.3A DC | 265V | 2.235 56.77mm | 1000V | ||||||||||||||||||
DRT-DTH-50-80 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Axial, Through Hole | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -20°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | 85.725mm | 500V | Lead Free | 15 Weeks | 50W | Axial | SPDT | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 50 ~ 80AT | 2A DC | 350V | 3.375 85.73mm | 500V | ||||||||
MARR-5-17-33 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | MARR-5 | Axial, Through Hole | Through Hole | -75°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -75°C | ROHS3 Compliant | 2003 | /files/littelfuseinc-marr52228-datasheets-5134.pdf | 0.2pF | 56.769mm | Lead Free | Unknown | 100mOhm | 10W | 100mOhm | Axial | SPST-NO | SPST | 1.3A | 0.75ms | 0.3ms | 10W | 0.105Diax0.775L 2.66mmx19.69mm | 350mA AC 500mA DC | 17 ~ 33AT | 1.3A DC | 265V | 2.235 56.77mm | 1000V | ||||||
DRT-DTH-80-95 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | Lead Free | Axial | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 80 ~ 95AT | 2A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
DRT-DTH-100-105 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | Lead Free | Axial | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 100 ~ 105AT | 2A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
MARR-5-22-28 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | MARR-5 | Axial, Through Hole | Through Hole | -75°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | 2015 | /files/littelfuseinc-marr52228-datasheets-5134.pdf | 0.2pF | 56.769mm | 1kV | Lead Free | 33 Weeks | unknown | 10W | Axial | SPST-NO | SPST | 0.75ms | 0.3ms | 0.105Diax0.775L 2.66mmx19.69mm | 350mA AC 500mA DC | 22 ~ 28AT | 1.3A DC | 265V | 2.235 56.77mm | 1000V | |||||||||||
DRT-DTH-70-80 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Axial | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | ROHS3 Compliant | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | Lead Free | Axial | SPDT | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 70 ~ 80AT | 2A DC | 350V | 3.375 85.73mm | 500V | |||||||||||||||
DRR-DTH-80-100 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | Lead Free | Axial | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 80 ~ 100AT | 3A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
DRR-DTH-80-90 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | Lead Free | Axial | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 80 ~ 90AT | 3A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
DRR-DTH-60-70 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Axial, Through Hole | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -20°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | 85.725mm | 500V | Lead Free | 11 Weeks | 30W | Axial | SPDT | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 60 ~ 70AT | 3A DC | 350V | 3.375 85.73mm | 500V | ||||||||
DRT-DTH-50-100 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | Lead Free | Axial | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 50 ~ 100AT | 2A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
DRT-DTH-60-80 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Axial, Through Hole | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -20°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | 85.725mm | 500V | Lead Free | 50W | Axial | SPDT | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 60 ~ 80AT | 2A DC | 350V | 3.375 85.73mm | 500V | |||||||||
CM5S1030 | Coto Technology |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Molded Body | CM5S | Surface Mount | -40°C~125°C | Bulk | 1 (Unlimited) | /files/cototechnology-cm5s1020-datasheets-4777.pdf | 0.3pF | Axial, Flat | SPST-NO | 0.4ms | 0.1ms | 5VA | 0.265Lx0.115W x 0.094 H 6.73mmx2.92mmx2.40mm | 250mA AC/DC | 10 ~ 30AT | 500mA AC/DC | 175V | 1.360 34.54mm | 175V | ||||||||||||||||||||
DRR-DTH-60-65 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Axial, Through Hole | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -20°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | 85.725mm | 500V | Lead Free | 30W | Axial | SPDT | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 60 ~ 65AT | 3A DC | 350V | 3.375 85.73mm | 500V | |||||||||
DRT-DTH-60-100 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRT-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drtdth6080-datasheets-5092.pdf | 2pF | Lead Free | Axial | SPDT | 5.5ms | 8ms | 50W | 0.210Diax1.500L 5.33mmx38.10mm | 1A AC 1.5A DC | 60 ~ 100AT | 2A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
DRR-DTH-50-100 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-DTH | Through Hole | -20°C~125°C | Bulk | 1 (Unlimited) | ROHS3 Compliant | /files/littelfuseinc-drrdth4050-datasheets-4949.pdf | 2pF | Lead Free | Axial | SPDT | 4.5ms | 7ms | 30W | 0.210Diax1.500L 5.33mmx38.10mm | 350mA AC 500mA DC | 50 ~ 100AT | 3A DC | 350V | 3.375 85.73mm | 500V | ||||||||||||||||||
DRR-129-77-88 | Littelfuse |
Min: 1 Mult: 1 |
0 | 0x0x0 | download | Glass Body | DRR-129 | Axial, Surface Mount | Surface Mount | -40°C~125°C | Bulk | 1 (Unlimited) | Axial | 125°C | -40°C | ROHS3 Compliant | 2002 | /files/littelfuseinc-drr129037-datasheets-4809.pdf | 0.6pF | 82.55mm | Lead Free | 100W | Axial, Flat | SPST-NO | SPST | 4.5ms | 2.5ms | 100W | 0.207Diax2.000L 5.25mmx50.80mm | 2.1A AC 3A DC | 77 ~ 88AT | 6A DC | 280V | 3.250 82.55mm | 400V |
Please send RFQ , we will respond immediately.