Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Type | Series | Mounting Type | Operating Temperature | Size / Dimension | Moisture Sensitivity Level (MSL) | Technology | Height Seated (Max) | RoHS Status | Published | Datasheet | Package / Case | Length | Height | Width | Number of Terminations | Factory Lead Time | Approval Agency | Pbfree Code | ECCN Code | Additional Feature | Number of Functions | Voltage - Input (Max) | JESD-609 Code | Feature | Terminal Finish | Applications | Surface Mount | Terminal Position | Terminal Form | Peak Reflow Temperature (Cel) | Terminal Pitch | Pin Count | Analog IC - Other Type | Time@Peak Reflow Temperature-Max (s) | Subcategory | Qualification Status | JESD-30 Code | Output Voltage | Power (Watts) | Number of Outputs | Voltage - Output 1 | Voltage - Isolation | Current - Output (Max) | Input Voltage-Nom | Trim/Adjustable Output | Total Power Output-Max | Voltage - Output 2 | Efficiency | Voltage - Input (Min) |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
TON 15-2411 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TON 15 (15W) | Through Hole | -40°C~85°C With Derating | 1.10Lx0.94W x 0.33 H 27.9mmx23.9mmx8.5mm | Not Applicable | HYBRID | 8.85mm | ROHS3 Compliant | 2005 | https://pdf.utmel.com/r/datasheets/tracopower-ton152411-datasheets-6353.pdf | 6-DIP Module | 27.94mm | 8.5mm | 23.88mm | 6 | 13 Weeks | UL | REMOTE SHUTDOWN | 1 | 36V | Remote On/Off, OCP, OVP, SCP, UVLO | ITE (Commercial) | NO | DUAL | 245 | 10 | Power Supply Modules | R-XDMA-T6 | 5.1V | 15W | 1 | 5V | 2.25kV | 3A | 24V | YES | 87% | 18V | ||||||||||||||||
THM 10-1213 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | THM 10 (10W) | Through Hole | -40°C~90°C With Derating | 1.25Lx0.80W x 0.40 H 31.8mmx20.3mmx10.2mm | Not Applicable | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-thm100511-datasheets-1515.pdf | 24-DIP Module, 5 Leads | 13 Weeks | 18V | OCP, OVP, SCP | Medical | 10W | 1 | 15V | 5kV | 670mA | 89% | 9V | |||||||||||||||||||||||||||||||||||
TEN 15-4813 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 15 (15W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-ten152413-datasheets-1924.pdf | 5-DIP Module, 4 Leads | 4 | 75V | OCP, OVP, SCP | ITE (Commercial) | Other Analog ICs | Not Qualified | 15V | 15W | 1 | 15V | 1.6kV | 1A | 86% | 36V | ||||||||||||||||||||||||||||||||
TEN 10-2413 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 10 (10W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | HYBRID | ROHS3 Compliant | 2014 | https://pdf.utmel.com/r/datasheets/tracopower-ten101211-datasheets-6393.pdf | 5-DIP Module, 4 Leads | 50.8mm | 25.4mm | 5 | 12 Weeks | yes | 1 | 36V | OCP, OVP, SCP | ITE (Commercial) | NO | DUAL | PIN/PEG | NOT SPECIFIED | 5 | NOT SPECIFIED | Other Analog ICs | Not Qualified | R-XDMA-P5 | 15V | 10W | 1 | 15V | 1.5kV | 670mA | 24V | NO | 82% | 18V | ||||||||||||||||
TVN 5-4810WI | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TVN 5WI (5W) | Through Hole | -40°C~90°C With Derating | 1.26Lx0.79W x 0.40 H 32.0mmx20.0mmx10.2mm | Not Applicable | ROHS3 Compliant | 2014 | https://pdf.utmel.com/r/datasheets/tracopower-tvn54811wi-datasheets-1480.pdf | 24-DIP Module, 10 Leads | 13 Weeks | EAR99 | 75V | Remote On/Off, OCP, OVP, SCP | ITE (Commercial) | 5W | 1 | 3.3V | 1.6kV | 1.515A | 80% | 18V | |||||||||||||||||||||||||||||||||
TRI 6-2412 | Traco Power |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 11 Weeks | DC-DC REGULATED POWER SUPPLY MODULE | |||||||||||||||||||||||||||||||||||||||||||||||||||
THM 15-4822 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | THM 15 (15W) | Through Hole | -40°C~85°C With Derating | 1.60Lx1.00W x 0.40 H 40.6mmx25.4mmx10.2mm | Not Applicable | HYBRID | 10.7mm | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-thm152413-datasheets-6755.pdf | 5-DIP Module | 40.6mm | 5 | 13 Weeks | EAR99 | 1 | 75V | OCP, OTP, OVP, SCP | Medical | NO | DUAL | PIN/PEG | NOT SPECIFIED | NOT SPECIFIED | R-PDMA-P5 | 12V | 15W | 2 | 12V | 5kV | 625mA 625mA | 48V | NO | 15W | -12V | 88.5% | 36V | ||||||||||||||||||
TRI 6-4822 | Traco Power |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 11 Weeks | DC-DC REGULATED POWER SUPPLY MODULE | |||||||||||||||||||||||||||||||||||||||||||||||||||
TEN 12-2421 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 12WI (12W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | HYBRID | 10.7mm | ROHS3 Compliant | 2001 | 5-DIP Module | 50.8mm | 5 | 1 | 36V | Remote On/Off, OCP, OVP, SCP | ITE (Commercial) | NO | DUAL | NOT SPECIFIED | NOT SPECIFIED | Other Analog ICs | Not Qualified | R-XDMA-T5 | 5V | 10W | 2 | 5V | 1.5kV | 1A 1A | 24V | NO | -5V | 82% | 9V | ||||||||||||||||||||
THN 15-2413WIR | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | THN 15WIR (15W) | Through Hole | -40°C~90°C With Derating | 1.00Lx1.00W x 0.39 H 25.4mmx25.4mmx9.9mm | Not Applicable | HYBRID | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-thn152411wir-datasheets-9203.pdf | 6-DIP Module | 25.4mm | 25.4mm | 6 | 13 Weeks | EAR99 | 1 | 36V | Remote On/Off, OVP, SCP, UVLO | ITE (Commercial), Railway | NO | DUAL | PIN/PEG | NOT SPECIFIED | NOT SPECIFIED | S-XDMA-P6 | 15V | 15W | 1 | 15V | 3kV | 1A | 24V | YES | 89% | 9V | ||||||||||||||||||||
THM 20-2415 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | THM 20 (20W) | Through Hole | -40°C~80°C With Derating | 1.60Lx1.00W x 0.40 H 40.6mmx25.4mmx10.2mm | Not Applicable | HYBRID | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-thm202412-datasheets-1083.pdf | 5-DIP Module | 40.6mm | 25.4mm | 5 | 13 Weeks | 1 | 36V | OCP, OTP, OVP, SCP | Medical | NO | DUAL | PIN/PEG | NOT SPECIFIED | NOT SPECIFIED | R-PDMA-P5 | 24V | 20W | 1 | 24V | 5kV | 833mA | 24V | YES | 20W | 90% | 18V | ||||||||||||||||||||
TEN 40-1222E | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 40E (40W) | Through Hole | -40°C~85°C | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | ROHS3 Compliant | 6-DIP Module | 1 Weeks | 18V | Adjustable Output, Remote On/Off | ITE (Commercial) | 40W | 2 | 12V | 1.6kV | 1.666A 1.666A | -12V | 90% | 9V | |||||||||||||||||||||||||||||||||||
TEN 30-2411 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 30 (30W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | HYBRID | ROHS3 Compliant | 2010 | https://pdf.utmel.com/r/datasheets/tracopower-ten302412-datasheets-1823.pdf | 6-DIP Module | 50.8mm | 25.4mm | 6 | 13 Weeks | yes | EAR99 | 1 | 36V | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | ITE (Commercial) | NO | DUAL | PIN/PEG | NOT SPECIFIED | 6 | NOT SPECIFIED | R-PDMA-P6 | 5.1V | 31W | 1 | 5.1V | 1.5kV | 6A | 24V | YES | 30W | 90% | 18V | ||||||||||||||||
TEN 30-1212 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 30 (30W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | HYBRID | ROHS3 Compliant | 2009 | https://pdf.utmel.com/r/datasheets/tracopower-ten302412-datasheets-1823.pdf | 6-DIP Module | 50.8mm | 25.4mm | 6 | 13 Weeks | SEATED HGT CALCULATED | 1 | 18V | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | ITE (Commercial) | NO | DUAL | NOT SPECIFIED | NOT SPECIFIED | R-MDMA-T6 | 12V | 30W | 1 | 12V | 1.5kV | 2.5A | 12V | YES | 30W | 89% | 9V | |||||||||||||||||||
TRI 10-4815 | Traco Power |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 11 Weeks | DC-DC REGULATED POWER SUPPLY MODULE | |||||||||||||||||||||||||||||||||||||||||||||||||||
TEN 40-1213E | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 40E (40W) | Through Hole | -40°C~85°C | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | ROHS3 Compliant | 6-DIP Module | 1 Weeks | 18V | Adjustable Output, Remote On/Off | ITE (Commercial) | 40W | 1 | 15V | 1.6kV | 2.666A | 91% | 9V | ||||||||||||||||||||||||||||||||||||
TEN 20-2423 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 20 (20W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | HYBRID | 10.7mm | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-ten202411-datasheets-1702.pdf | 6-DIP Module | 50.8mm | 6 | 11 Weeks | yes | EAR99 | -15 VOLT ADDITIONAL OUTPUT IS AVAILABLE | 1 | 36V | SCP | ITE (Commercial) | NOT SPECIFIED | NOT SPECIFIED | Other Analog ICs | Not Qualified | 15V | 20W | 2 | 15V | 1.5kV | 670mA 670mA | 24V | YES | -15V | 89% | 18V | |||||||||||||||||||
TEN 40-2411WIE | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 40WIE (40W) | Through Hole | -40°C~85°C | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | ROHS3 Compliant | 6-DIP Module | 1 Weeks | 36V | Adjustable Output, Remote On/Off | ITE (Commercial) | 40W | 1 | 5V | 1.6kV | 8A | 92% | 9V | ||||||||||||||||||||||||||||||||||||
TEN 25-4822 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 25 (30W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.60W x 0.37 H 50.8mmx40.6mmx9.5mm | Not Applicable | HYBRID | 9.3mm | ROHS3 Compliant | 2010 | https://pdf.utmel.com/r/datasheets/tracopower-ten251211-datasheets-8199.pdf | 7-DIP Module | 50.8mm | 40.6mm | 7 | 1 | 75V | Remote On/Off, OCP, OVP, SCP | ITE (Commercial) | NO | DUAL | PIN/PEG | NOT SPECIFIED | NOT SPECIFIED | R-XDMA-P7 | 12V | 30W | 2 | 12V | 1.5kV | 1.25A 1.25A | 48V | YES | 30W | -12V | 89% | 48V | ||||||||||||||||||
TRI 15-1215 | Traco Power |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 11 Weeks | DC-DC REGULATED POWER SUPPLY MODULE | |||||||||||||||||||||||||||||||||||||||||||||||||||
TEN 40-4813WIE | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 40WIE (40W) | Through Hole | -40°C~85°C | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | ROHS3 Compliant | 6-DIP Module | 1 Weeks | 75V | Adjustable Output, Remote On/Off | ITE (Commercial) | 40W | 1 | 15V | 1.6kV | 2.666A | 92% | 18V | ||||||||||||||||||||||||||||||||||||
THN 30-4810WI | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | THN 30WI (30W) | Through Hole | -40°C~80°C With Derating | 1.00Lx1.00W x 0.39 H 25.4mmx25.4mmx9.9mm | Not Applicable | HYBRID | ROHS3 Compliant | 2012 | https://pdf.utmel.com/r/datasheets/tracopower-thn304815wi-datasheets-9951.pdf | 6-DIP Module | 25.4mm | 25.4mm | 6 | 13 Weeks | EAR99 | 1 | 75V | Remote On/Off, OTP, OVP, SCP, UVLO | ITE (Commercial) | NO | DUAL | PIN/PEG | NOT SPECIFIED | NOT SPECIFIED | S-MDMA-P6 | 3.3V | 23W | 1 | 3.3V | 1.5kV | 7A | 48V | YES | 87% | 18V | |||||||||||||||||||
TEN 20-4811WI | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 20WI (20W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.60W x 0.40 H 50.8mmx40.6mmx10.2mm | Not Applicable | HYBRID | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-ten202411wi-datasheets-8852.pdf | 7-DIP Module, 6 Leads | 50.8mm | 25.4mm | 6 | yes | EAR99 | 1 | 75V | Remote On/Off, OCP, OVP, SCP | ITE (Commercial) | NOT SPECIFIED | NOT SPECIFIED | Other Analog ICs | Not Qualified | 5V | 20W | 1 | 5V | 1.5kV | 4A | 48V | YES | 20W | 80% | 18V | |||||||||||||||||||||
TRI 20-2415 | Traco Power |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 11 Weeks | DC-DC REGULATED POWER SUPPLY MODULE | |||||||||||||||||||||||||||||||||||||||||||||||||||
THM 30-4823 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | THM 30 (30W) | Through Hole | -40°C~80°C With Derating | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | HYBRID | 10.7mm | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-thm302415-datasheets-6196.pdf | 5-DIP Module | 50.8mm | 6 | 13 Weeks | EAR99 | 1 | 75V | OCP, OTP, OVP, SCP | Medical | NO | DUAL | PIN/PEG | NOT SPECIFIED | NOT SPECIFIED | R-PDMA-P6 | 15V | 30W | 2 | 15V | 5kV | 1A 1A | 48V | NO | 30W | -15V | 89% | 36V | ||||||||||||||||||
TEN 20-2413WIN | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 20WIN (20W) | Through Hole | -40°C~85°C With Derating | 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm | Not Applicable | ROHS3 Compliant | 2010 | https://pdf.utmel.com/r/datasheets/tracopower-ten202411win-datasheets-8683.pdf | 6-DIP Module | 13 Weeks | 36V | Remote On/Off, OCP, OVP, SCP | ITE (Commercial) | 20W | 1 | 15V | 1.5kV | 1.33A | 86% | 9V | ||||||||||||||||||||||||||||||||||
TDN 1-2411WISM | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TDN 1WISM (1W) | Surface Mount | -40°C~90°C | 0.52Lx0.36W x 0.40 H 13.2mmx9.1mmx10.2mm | 2 (1 Year) | HYBRID | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/tracopower-tdn11211wism-datasheets-2557.pdf | 7-SMD Module, 6 Leads | 6 | 13 Weeks | EAR99 | 1 | 36V | Remote On/Off, SCP | ITE (Commercial) | YES | DUAL | FLAT | NOT SPECIFIED | 2mm | NOT SPECIFIED | R-PDMA-F6 | 5V | 1W | 1 | 5V | 1.6kV | 200mA | 24V | NO | 1W | 78% | 9V | ||||||||||||||||||||
TEN 3-1212 | Traco Power | $19.57 |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 3 (3W) | Through Hole | -40°C~85°C With Derating | 1.25Lx0.80W x 0.40 H 31.8mmx20.3mmx10.2mm | Not Applicable | HYBRID | ROHS3 Compliant | 2009 | https://pdf.utmel.com/r/datasheets/tracopower-ten32423-datasheets-2684.pdf | 24-DIP Module, 7 Leads | 20.3mm | 8 | 11 Weeks | yes | EAR99 | 1 | 18V | e4 | SCP | ITE (Commercial) | NO | DUAL | PIN/PEG | NOT SPECIFIED | 2.54mm | NOT SPECIFIED | Other Analog ICs | Not Qualified | R-PDMA-P8 | 12V | 3W | 1 | 12V | 1.5kV | 250mA | 12V | NO | 3W | 82% | 9V | |||||||||||||
TEN 3-1221 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TEN 3 (3W) | Through Hole | -40°C~85°C With Derating | 1.25Lx0.80W x 0.40 H 31.8mmx20.3mmx10.2mm | Not Applicable | HYBRID | 10.45mm | ROHS3 Compliant | 2009 | https://pdf.utmel.com/r/datasheets/tracopower-ten32423-datasheets-2684.pdf | 24-DIP Module, 8 Leads | 31.8mm | 8 | 11 Weeks | yes | EAR99 | 1 | 18V | e4 | SCP | GOLD (5) OVER NICKEL (100) | ITE (Commercial) | NO | DUAL | PIN/PEG | NOT SPECIFIED | NOT SPECIFIED | Other Analog ICs | Not Qualified | R-PDMA-P8 | 5V | 2.5W | 2 | 5V | 1.5kV | 250mA 250mA | 12V | NO | -5V | 77% | 9V | |||||||||||||
TMR 3-4810 | Traco Power |
Min: 1 Mult: 1 |
download | Isolated Module | TMR 3 (3W) | Through Hole | -40°C~85°C With Derating | 0.86Lx0.36W x 0.44 H 21.8mmx9.2mmx11.1mm | Not Applicable | HYBRID | ROHS3 Compliant | 2007 | https://pdf.utmel.com/r/datasheets/tracopower-tmr30511-datasheets-7856.pdf | 8-SIP Module, 7 Leads | 9.2mm | 7 | 13 Weeks | yes | EAR99 | 1 | 75V | e3 | Remote On/Off, SCP | Matte Tin (Sn) - with Nickel (Ni) barrier | ITE (Commercial) | NO | SINGLE | PIN/PEG | NOT SPECIFIED | 2.54mm | 8/7 | NOT SPECIFIED | Other Analog ICs | Not Qualified | R-XSMA-P7 | 3.3V | 2.3W | 1 | 3.3V | 1.6kV | 700mA | 48V | NO | 74% | 36V |
Please send RFQ , we will respond immediately.