Traco Power(8126)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Type Series Mounting Type Operating Temperature Size / Dimension Moisture Sensitivity Level (MSL) Technology Height Seated (Max) RoHS Status Published Datasheet Package / Case Length Height Width Number of Terminations Factory Lead Time Approval Agency Pbfree Code ECCN Code Additional Feature Number of Functions Voltage - Input (Max) Feature Terminal Finish Applications Surface Mount Terminal Position Terminal Form Peak Reflow Temperature (Cel) Terminal Pitch Pin Count Analog IC - Other Type Time@Peak Reflow Temperature-Max (s) Subcategory Qualification Status JESD-30 Code Output Voltage Power (Watts) Number of Outputs Voltage - Output 1 Voltage - Isolation Current - Output (Max) Input Voltage-Nom Trim/Adjustable Output Total Power Output-Max Voltage - Output 2 Efficiency Control Mode Voltage - Input (Min) Protections Warm-up Time
THM 10-0511WI THM 10-0511WI Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module THM 10WI (10W) Through Hole -40°C~90°C With Derating 1.25Lx0.80W x 0.40 H 31.8mmx20.3mmx10.2mm Not Applicable ROHS3 Compliant 2013 https://pdf.utmel.com/r/datasheets/tracopower-thm102411wi-datasheets-8908.pdf 24-DIP Module, 6 Leads 13 Weeks EAR99 9V OCP, OVP, SCP Medical NOT SPECIFIED NOT SPECIFIED 10W 1 5V 5kV 2A 84% 4.5V
THN 20-2411WI-A1 THN 20-2411WI-A1 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module THN 20WI-A1 (20W) Through Hole -40°C~75°C With Derating 1.00Lx1.00W x 0.39 H 25.4mmx25.4mmx9.9mm Not Applicable HYBRID ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-thn202412wi-datasheets-8710.pdf 6-DIP Module 25.4mm 25.4mm 6 1 Weeks 1 36V Remote On/Off, OVP, SCP ITE (Commercial) NO DUAL PIN/PEG S-MDMA-P6 5V 20W 1 5V 1.5kV 4A 24V YES 20W 89% 9V
TEN 10-1223 TEN 10-1223 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 10 (10W) Through Hole -40°C~85°C With Derating 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm Not Applicable HYBRID 10.7mm ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/tracopower-ten101211-datasheets-6393.pdf 5-DIP Module 50.8mm 5 yes 1 18V OCP, OVP, SCP ITE (Commercial) NO DUAL PIN/PEG NOT SPECIFIED 5 NOT SPECIFIED Other Analog ICs Not Qualified R-XDMA-P5 15V 10W 2 15V 1.5kV 330mA 330mA 12V NO 10W -15V 80% 9V
THN 20-1223 THN 20-1223 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module THN 20 (20W) Through Hole -40°C~75°C With Derating 1.00Lx1.00W x 0.39 H 25.4mmx25.4mmx9.9mm Not Applicable HYBRID 10.4mm ROHS3 Compliant 2013 https://pdf.utmel.com/r/datasheets/tracopower-thn201211-datasheets-8716.pdf 6-DIP Module 10.4mm 6 13 Weeks EN, IEC, UL EAR99 1 18V Remote On/Off, OVP, SCP ITE (Commercial) NO DUAL S-MDMA-T6 15V 20W 2 15V 1.5kV 667mA 667mA 12V NO -15V 89% VOLTAGE-MODE 9V OUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE 0.03 s
THM 15-4823 THM 15-4823 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module THM 15 (15W) Through Hole -40°C~85°C With Derating 1.60Lx1.00W x 0.40 H 40.6mmx25.4mmx10.2mm Not Applicable HYBRID 10.7mm ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-thm152413-datasheets-6755.pdf 5-DIP Module 40.6mm 5 13 Weeks EAR99 IT ALSO HAS -15 V OUTPUT 1 75V OCP, OTP, OVP, SCP Medical NO DUAL PIN/PEG NOT SPECIFIED NOT SPECIFIED R-PDMA-P5 15V 15W 2 15V 5kV 500mA 500mA 48V NO 15W -15V 89% 36V
THN 10-7223WIR THN 10-7223WIR Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module THN 10WIR (10W) Through Hole -40°C~105°C 1.00Lx1.00W x 0.39 H 25.4mmx25.4mmx9.9mm 1 (Unlimited) ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-thn102415wir-datasheets-4426.pdf 6-DIP Module 13 Weeks 160V Adjustable Output, Remote On/Off ITE (Commercial), Railway 10W 2 15V 3kV 333mA 333mA -15V 89% 36V
TVN 5-2425WI TVN 5-2425WI Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TVN 5WI (5W) Through Hole -40°C~90°C With Derating 1.26Lx0.79W x 0.40 H 32.0mmx20.0mmx10.2mm Not Applicable ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/tracopower-tvn54811wi-datasheets-1480.pdf 24-DIP Module, 12 Leads 13 Weeks EAR99 36V Remote On/Off, OCP, OVP, SCP ITE (Commercial) 5W 2 24V 1.6kV 104mA 104mA -24V 87% 9V
THM 20-4812 THM 20-4812 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module THM 20 (20W) Through Hole -40°C~80°C With Derating 1.60Lx1.00W x 0.40 H 40.6mmx25.4mmx10.2mm Not Applicable HYBRID ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-thm202412-datasheets-1083.pdf 5-DIP Module 40.6mm 25.4mm 5 13 Weeks 1 75V OCP, OTP, OVP, SCP Medical NO DUAL PIN/PEG NOT SPECIFIED NOT SPECIFIED R-PDMA-P5 12V 20W 1 12V 5kV 1.67A 48V YES 20W 88% 36V
THM 20-2413 THM 20-2413 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module THM 20 (20W) Through Hole -40°C~80°C With Derating 1.60Lx1.00W x 0.40 H 40.6mmx25.4mmx10.2mm Not Applicable HYBRID ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-thm202412-datasheets-1083.pdf 5-DIP Module 40.6mm 25.4mm 5 13 Weeks 1 36V OCP, OTP, OVP, SCP Medical NO DUAL PIN/PEG NOT SPECIFIED NOT SPECIFIED R-PDMA-P5 15V 20W 1 15V 5kV 1.33A 24V YES 20W 90% 18V
TEN 20-4812 TEN 20-4812 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 20 (20W) Through Hole -40°C~85°C With Derating 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm Not Applicable HYBRID ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-ten202411-datasheets-1702.pdf 6-DIP Module 50.8mm 25.4mm 6 11 Weeks EAR99 SEATED HGT CALCULATED 1 75V SCP ITE (Commercial) NO DUAL NOT SPECIFIED NOT SPECIFIED R-MDMA-T6 12V 20W 1 12V 1.5kV 1.67A 48V YES 20W 89% 36V
TEN 15-2422WI TEN 15-2422WI Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 15WI (15W) Through Hole -40°C~85°C With Derating 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm Not Applicable HYBRID 10.7mm ROHS3 Compliant 2006 https://pdf.utmel.com/r/datasheets/tracopower-ten152412wi-datasheets-7405.pdf 6-DIP Module 50.8mm 6 yes EAR99 1 36V Remote On/Off, SCP ITE (Commercial) NO DUAL PIN/PEG NOT SPECIFIED 6 NOT SPECIFIED Other Analog ICs Not Qualified R-XDMA-P6 12V 15W 2 12V 1.5kV 625mA 625mA 24V NO -12V 85% 9V
TEN 25-2413WI TEN 25-2413WI Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 25WI (30W) Through Hole -40°C~85°C With Derating 2.00Lx1.60W x 0.37 H 50.8mmx40.6mmx9.3mm Not Applicable HYBRID 9.3mm ROHS3 Compliant 2010 https://pdf.utmel.com/r/datasheets/tracopower-tenhs5-datasheets-3893.pdf 7-DIP Module, 6 Leads 50.8mm 40.6mm 7 11 Weeks 1 40V Remote On/Off, OTP, OVP, SCP, UVLO ITE (Commercial) NO DUAL PIN/PEG NOT SPECIFIED NOT SPECIFIED R-XDMA-P7 15V 30W 1 15V 1.5kV 2A 24V YES 30W 89% 10V
TRI 10-2412 TRI 10-2412 Traco Power
RFQ

Min: 1

Mult: 1

download Not Applicable ROHS3 Compliant 11 Weeks DC-DC REGULATED POWER SUPPLY MODULE
TVN 5-0910WI TVN 5-0910WI Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TVN 5WI (5W) Through Hole -40°C~90°C With Derating 1.26Lx0.79W x 0.40 H 32.0mmx20.0mmx10.2mm Not Applicable HYBRID ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-tvn54811wi-datasheets-1480.pdf 24-DIP Module, 12 Leads 32mm 20mm 12 13 Weeks 1 12V Remote On/Off, OCP, OVP, SCP ITE (Commercial) NO DUAL PIN/PEG 2.54mm 3.3V 5W 1 3.3V 1.6kV 1.515A 9V NO 5W 79% 4.5V
TEN 30-2423 TEN 30-2423 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 30 (30W) Through Hole -40°C~85°C With Derating 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm Not Applicable HYBRID 10.7mm ROHS3 Compliant 2010 https://pdf.utmel.com/r/datasheets/tracopower-ten302412-datasheets-1823.pdf 6-DIP Module 50.8mm 6 13 Weeks 1 36V Remote On/Off, OCP, OTP, OVP, SCP, UVLO ITE (Commercial) NO DUAL NOT SPECIFIED NOT SPECIFIED R-MDMA-T6 15V 30W 2 15V 1.5kV 1A 1A 24V NO 30W -15V 90% 18V
TRI 10-1211 TRI 10-1211 Traco Power
RFQ

Min: 1

Mult: 1

download Not Applicable ROHS3 Compliant 11 Weeks DC-DC REGULATED POWER SUPPLY MODULE
TRI 15-4823 TRI 15-4823 Traco Power
RFQ

Min: 1

Mult: 1

download Not Applicable ROHS3 Compliant 11 Weeks DC-DC REGULATED POWER SUPPLY MODULE
TEN 20-2412WIR TEN 20-2412WIR Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 20WIR (20W) Through Hole -40°C~85°C With Derating 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm Not Applicable HYBRID ROHS3 Compliant 2010 https://pdf.utmel.com/r/datasheets/tracopower-ten202412wir-datasheets-8564.pdf 6-DIP Module 50.8mm 25.4mm 6 13 Weeks EAR99 SEATED HGT CALCULATED 1 36V Remote On/Off, OCP, OVP, SCP ITE (Commercial), Railway NO DUAL NOT SPECIFIED NOT SPECIFIED R-MDMA-T6 12V 20W 1 12V 2.25kV 1.67A 24V YES 20W 89% 9V
THN 30-4811WI-A1 THN 30-4811WI-A1 Traco Power $82.69
RFQ

Min: 1

Mult: 1

download Isolated Module THN 30WI-A1 (30W) Through Hole -40°C~80°C With Derating 1.00Lx1.00W x 0.39 H 25.4mmx25.4mmx9.9mm Not Applicable ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-thn304815wi-datasheets-9951.pdf 6-DIP Module 1 Weeks 75V Remote On/Off, OTP, OVP, SCP, UVLO ITE (Commercial) 30W 1 5V 1.5kV 6A 90% 18V
TEN 30-4822WIN TEN 30-4822WIN Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 30WIN (30W) Through Hole -40°C~75°C With Derating 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm Not Applicable HYBRID 10.5mm ROHS3 Compliant 2010 https://pdf.utmel.com/r/datasheets/tracopower-ten302422win-datasheets-6128.pdf 7-DIP Module, 6 Leads 50.8mm 6 13 Weeks yes EAR99 1 75V Remote On/Off, OCP, OTP, OVP, SCP, UVLO ITE (Commercial) NO DUAL PIN/PEG NOT SPECIFIED 6 NOT SPECIFIED R-PDMA-P6 12V 30W 2 12V 1.5kV 1.25A 1.25A 48V NO 30W -12V 88% 18V
THM 30-2422 THM 30-2422 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module THM 30 (30W) Through Hole -40°C~80°C With Derating 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm Not Applicable HYBRID 10.7mm ROHS3 Compliant https://pdf.utmel.com/r/datasheets/tracopower-thm302415-datasheets-6196.pdf 5-DIP Module 50.8mm 6 13 Weeks EAR99 1 36V OCP, OTP, OVP, SCP Medical NO DUAL PIN/PEG NOT SPECIFIED NOT SPECIFIED R-PDMA-P6 12V 30W 2 12V 5kV 1.25A 1.25A 24V NO 30W -12V 88.5% 18V
TEN 25-1212 TEN 25-1212 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 25 (30W) Through Hole -40°C~85°C With Derating 2.00Lx1.60W x 0.37 H 50.8mmx40.6mmx9.5mm Not Applicable HYBRID ROHS3 Compliant 2010 https://pdf.utmel.com/r/datasheets/tracopower-ten251211-datasheets-8199.pdf 7-DIP Module, 6 Leads 50.8mm 40.6mm 7 yes 1 18V Remote On/Off, OCP, OVP, SCP ITE (Commercial) NO DUAL PIN/PEG NOT SPECIFIED 7 NOT SPECIFIED R-MDMA-P7 12V 30W 1 12V 1.5kV 2.5A 12V YES 30W 88% 9V
TEN 15-2411 TEN 15-2411 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 15 (15W) Through Hole -40°C~85°C With Derating 2.00Lx1.00W x 0.40 H 50.8mmx25.4mmx10.2mm Not Applicable HYBRID ROHS3 Compliant 2010 https://pdf.utmel.com/r/datasheets/tracopower-ten152413-datasheets-1924.pdf 5-DIP Module, 4 Leads 50.8mm 25.4mm 6 3 Weeks yes EAR99 1 36V OCP, OVP, SCP Nickel (Ni) ITE (Commercial) NO DUAL PIN/PEG NOT SPECIFIED 6 NOT SPECIFIED Other Analog ICs Not Qualified R-XDMA-P6 5.1V 15W 1 5V 1.6kV 3A 24V NO 84% 18V
TMR 3-2423E TMR 3-2423E Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TMR 3E (3W) Through Hole -40°C~85°C With Derating 0.86Lx0.37W x 0.44 H 21.8mmx9.3mmx11.2mm Not Applicable HYBRID 11.7mm ROHS3 Compliant 2014 https://pdf.utmel.com/r/datasheets/tracopower-tmr30510e-datasheets-4357.pdf 8-SIP Module, 7 Leads 9.3mm 7 11 Weeks EAR99 1 36V Remote On/Off, SCP ITE (Commercial) NO SINGLE R-PSMA-T7 15V 3W 2 15V 1.5kV 100mA 100mA 24V NO 3W -15V 83% 18V
TMR 2-4810WI TMR 2-4810WI Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TMR 2WI (2W) Through Hole -40°C~85°C With Derating 1.02Lx0.37W x 0.49 H 26.0mmx9.3mmx12.5mm Not Applicable HYBRID ROHS3 Compliant 2012 https://pdf.utmel.com/r/datasheets/tracopower-tmr22423wi-datasheets-0756.pdf 9-SIP Module, 7 Leads 26mm 9.3mm 7 11 Weeks yes EAR99 1 75V Remote On/Off, SCP ITE (Commercial) NO SINGLE PIN/PEG NOT SPECIFIED 2.54mm NOT SPECIFIED Other Analog ICs Not Qualified R-PSMA-P7 3.3V 1.7W 1 3.3V 1.5kV 500mA 48V NO 70% 18V
TEN 3-0521 TEN 3-0521 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 3 (3W) Through Hole -40°C~85°C With Derating 1.25Lx0.80W x 0.40 H 31.8mmx20.3mmx10.2mm Not Applicable HYBRID 10.45mm ROHS3 Compliant 2009 https://pdf.utmel.com/r/datasheets/tracopower-ten32423-datasheets-2684.pdf 24-DIP Module, 8 Leads 31.8mm 8 11 Weeks EAR99 1 9V SCP ITE (Commercial) NO DUAL PIN/PEG NOT SPECIFIED NOT SPECIFIED Other Analog ICs Not Qualified R-PDMA-P8 5V 2.5W 2 5V 1.5kV 250mA 250mA 5V NO -5V 72% 4.5V
TMR 3-1213 TMR 3-1213 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TMR 3 (3W) Through Hole -40°C~85°C With Derating 0.86Lx0.36W x 0.44 H 21.8mmx9.2mmx11.1mm Not Applicable HYBRID ROHS3 Compliant 2007 https://pdf.utmel.com/r/datasheets/tracopower-tmr30511-datasheets-7856.pdf 8-SIP Module, 7 Leads 9.2mm 7 13 Weeks yes EAR99 1 18V Remote On/Off, SCP ITE (Commercial) NO SINGLE NOT SPECIFIED 2.54mm NOT SPECIFIED Other Analog ICs Not Qualified 15V 3W 1 15V 1.6kV 200mA 12V NO 3W 83% 9V
TMR 6-4811 TMR 6-4811 Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TMR 6 (6W) Through Hole -40°C~65°C 0.86Lx0.36W x 0.44 H 21.8mmx9.1mmx11.2mm Not Applicable HYBRID ROHS3 Compliant 2012 https://pdf.utmel.com/r/datasheets/tracopower-tmr62412-datasheets-7401.pdf 8-SIP Module, 7 Leads 7 13 Weeks EAR99 1 75V Remote On/Off, SCP ITE (Commercial) NO SINGLE PIN/PEG NOT SPECIFIED 2.54mm 8/7 NOT SPECIFIED Other Analog ICs Not Qualified R-PSMA-P7 5V 6W 1 5V 1.6kV 1.2A 48V NO 6W 82% 36V
TEN 6-4811WIN TEN 6-4811WIN Traco Power
RFQ

Min: 1

Mult: 1

download Isolated Module TEN 6WIN (6W) Through Hole -40°C~85°C With Derating 1.25Lx0.80W x 0.40 H 31.8mmx20.3mmx10.2mm Not Applicable HYBRID ROHS3 Compliant 2012 https://pdf.utmel.com/r/datasheets/tracopower-ten62411win-datasheets-0304.pdf 24-DIP Module, 7 Leads 20.3mm 8 11 Weeks 1 75V OCP, SCP ITE (Commercial) NO DUAL PIN/PEG NOT SPECIFIED 2.54mm NOT SPECIFIED R-PDMA-P8 5V 6W 1 5V 1.5kV 1.2A 48V NO 6W 80% 18V
TOS 06-12SM TOS 06-12SM Traco Power
RFQ

Min: 1

Mult: 1

download Non-Isolated PoL Module TOS Surface Mount -40°C~85°C 1.30Lx0.53W x 0.33 H 33.0mmx13.5mmx8.3mm 2A (4 Weeks) HYBRID 8.28mm ROHS3 Compliant 2006 5-SMD Module 33mm 7 13 Weeks EAR99 SEIGHTED HGT NOM 1 14V Remote On/Off, OCP, OTP, SCP ITE (Commercial) NO DUAL NO LEAD 265 2.54mm 10 R-XDMA-N7 30W 1 0.75V~5V 6A 12V YES 89% 8.3V

In Stock

Please send RFQ , we will respond immediately.