| Compare | Image | Name | Manufacturer | Pricing(USD) | Quantity | Weight(Kg) | Size(LxWxH) | Part Status | Series | Mount | Mounting Type | Packaging | Moisture Sensitivity Level (MSL) | Termination | RoHS Status | Published | Datasheet | Package / Case | Length | Width | Color | Material | Depth | Factory Lead Time | Weight | REACH SVHC | Pbfree Code | Connector Type | Gender | Orientation | ECCN Code | Contact Material | Contact Plating | Radiation Hardening | HTS Code | Wire/Cable Gauge | Feature | Body Material | Insulation Material | Terminal and Terminal Block Type | Body Plating | Wire Gauge | Wire Cross Section | Wire Gauge (Max) | Wire Gauge (Min) | Terminal Type | Length - Overall | Terminal Material | Terminal Gender | Insulation | Insulation Diameter | Tab Thickness | Contact Finish | Width - Tab | Material - Insulation | Stud/Tab Size | Width - Outer Edges | Tongue Inside Opening | Diameter - Barrel OD | Diameter - Barrel ID | Terminal Style | Diameter - Ring ID | Length - Tab |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| PV18-6LFX-CY | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pv1810lfxm-datasheets-4845.pdf | 24.13mm | Red | 6.86mm | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Spring, Snap | 0.950 24.13mm | Insulated | 0.170 (4.32mm) | Vinyl | 6 Stud | 0.270 6.86mm | 0.150 (3.81mm) | |||||||||||||||||||||||||||||
| LCC1-12F-E | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | https://pdf.utmel.com/r/datasheets/panduit-lcc112fe-datasheets-1788.pdf | 93.5mm | Green | 19.1mm | 4 Weeks | yes | EAR99 | Copper | No | 8536.90.40.00 | 1 AWG | WIRE TERMINAL | Tin | 1 AWG | Rectangular Tongue | Non-Insulated | 0.090 2.29mm | Electro-Tin | 1/2 Stud | 0.750 19.05mm | 0.470 (11.94mm) | 0.360 (9.14mm) | Two Stud Holes | 0.530 (13.46mm) | ||||||||||||||||||||||||||||
| DNF18-206-C | Panduit Corp | $1.22 |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2007 | 19.304mm | 6.35mm | Red | 4 Weeks | INTERCONNECTION DEVICE | Female | Brass | No | Serrated Termination | Nylon | 18-22 AWG | 22 AWG | 18 AWG | Standard | 0.760 19.30mm | Non-Mating End Insulated | 0.137 (3.48mm) | 0.020 0.51mm | Tin | 0.187 4.75mm 0.205 5.21mm | |||||||||||||||||||||||||||||||
| PN18-8LF-C | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduit-pn188lfc-datasheets-2022.pdf | 22.606mm | 7.37mm | Red | 7.4mm | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | Serrated Termination | FORK TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Spring, Snap | 0.890 22.61mm | FEMALE | Insulated | 0.145 (3.68mm) | Polyamide (PA), Nylon | 8 Stud | 0.290 7.37mm | 0.160 (4.06mm) | |||||||||||||||||||||||||||
| LCC2/0-38DH-X | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), 45° Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | https://pdf.utmel.com/r/datasheets/panduit-lcc2038dhx-datasheets-1813.pdf | Black | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | RING TERMINAL | 2/0 AWG | 67.46 mm2 | Rectangular Tongue | Non-Insulated | 0.130 3.30mm | Electro-Tin | 3/8 Stud | 0.850 21.59mm | 0.580 (14.73mm) | 0.450 (11.43mm) | Two Stud Holes | 0.410 (10.41mm) | |||||||||||||||||||||||||||||||
| DR18-206-C | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2006 | 13.5mm | 13.7mm | 4 Weeks | Female | EAR99 | Brass | Tin | No | 8536.90.40.00 | Serrated Termination | PUSH-ON TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Angled - 90°, Flag | Non-Insulated | 0.020 0.51mm | 0.187 4.75mm 0.205 5.21mm | ||||||||||||||||||||||||||||||||||
| PNF14-8F-C | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pnf1414fm-datasheets-4779.pdf | 21.59mm | 7.87mm | Blue | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.850 21.59mm | FEMALE | Insulated | 0.162 (4.11mm) | Tin | Polyamide (PA), Nylon | 8 Stud | 0.310 7.87mm | 0.170 (4.32mm) | ||||||||||||||||||||||||||||
| LCC1/0-12DF-X | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2004 | Pink | 4 Weeks | yes | EAR99 | Copper | Tin | No | 8536.90.40.00 | WIRE TERMINAL | 1/0 AWG | Rectangular Tongue | Non-Insulated | 0.120 3.05mm | Electro-Tin | 1/2 Stud | 0.800 20.32mm | 0.520 (13.21mm) | 0.390 (9.91mm) | Two Stud Holes | 0.530 (13.46mm) | ||||||||||||||||||||||||||||||||
| DV14-250B-3K | Panduit Corp | $0.35 |
Min: 1 Mult: 1 |
download | Disco™ | Free Hanging | Free Hanging (In-Line) | Tape & Reel (TR) | Not Applicable | Crimp | ROHS3 Compliant | 2005 | https://pdf.utmel.com/r/datasheets/panduitcorp-dv14206b3k-datasheets-9732.pdf | 600 | 21.1mm | Blue | 7.4mm | 4 Weeks | Female | EAR99 | Brass | No | 8536.90.40.00 | Butted Seam, Serrated Termination | Vinyl | PUSH-ON TERMINAL | 14-16 AWG | 2.5 mm2 | 16 AWG | 14 AWG | Standard | 0.830 21.08mm | Non-Mating End Insulated | 0.170 (4.32mm) | 0.032 0.81mm | Tin | 0.250 6.35mm | ||||||||||||||||||||||||||
| PN14-8F-E | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | 21.59mm | Blue | 4 Weeks | Copper | Tin | No | Serrated Termination | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.850 21.59mm | Insulated | 0.080 ~ 0.162 (2.03mm ~ 4.11mm) | Tin | Polyamide (PA), Nylon | 8 Stud | 0.310 7.87mm | 0.170 (4.32mm) | |||||||||||||||||||||||||||||||||
| LCMB95-16-X | Panduit Corp |
Min: 1 Mult: 1 |
download | LCMB | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2013 | https://pdf.utmel.com/r/datasheets/panduitcorp-lcmb12012x-datasheets-2689.pdf | 78.994mm | 4 Weeks | EAR99 | Copper | 8536.90.40.00 | 95mm2 | Ring, Tubular | 3.110 79.00mm | Non-Insulated | 0.114 2.90mm | Tin | M16 Stud | 0.965 24.51mm | 0.650 (16.51mm) | 0.531 (13.49mm) | Single Stud Hole | 0.709 (18.01mm) | ||||||||||||||||||||||||||||||||||
| DV14-187B-3K | Panduit Corp |
Min: 1 Mult: 1 |
download | Disco™ | Free Hanging | Free Hanging (In-Line) | Tape & Reel (TR) | Not Applicable | Crimp | ROHS3 Compliant | 2009 | https://pdf.utmel.com/r/datasheets/panduitcorp-dv14206b3k-datasheets-9732.pdf | 19.558mm | Blue | 5.8mm | 4 Weeks | Female | EAR99 | Brass | Tin | No | 8536.90.40.00 | Butted Seam, Serrated Termination | PUSH-ON TERMINAL | 14-16 AWG | 2.5 mm2 | 16 AWG | 14 AWG | Standard | 0.770 19.56mm | Non-Mating End Insulated | 0.170 (4.32mm) | 0.032 0.81mm | 0.187 4.75mm | |||||||||||||||||||||||||||||
| PNF18-6LFW-C | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | /files/panduitcorp-pnf1810lfc-datasheets-3239.pdf | 21.59mm | 7.366mm | Red | 7.4mm | 4 Weeks | 99.790321g | EAR99 | Copper | Tin | No | 8536.90.40.00 | FORK TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Spring, Snap | 0.850 21.59mm | FEMALE | Insulated | 0.145 (3.68mm) | Polyamide (PA), Nylon | 6 Stud | 0.290 7.37mm | 0.150 (3.81mm) | |||||||||||||||||||||||||||
| LCDX2/0-14BH-X | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), 45° Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2011 | https://pdf.utmel.com/r/datasheets/panduit-lcdx2014bhx-datasheets-1937.pdf | 61.7mm | Black | 24.4mm | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 2/0 AWG | Rectangular Tongue | FEMALE | Non-Insulated | 0.130 3.30mm | Electro-Tin | 1/4 Stud | 0.960 24.38mm | 0.640 (16.26mm) | 0.510 (12.95mm) | Two Stud Holes | 0.270 (6.86mm) | |||||||||||||||||||||||||||||
| ED14-188-L | Panduit Corp |
Min: 1 Mult: 1 |
download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-ed18188l-datasheets-5580.pdf | 6 Weeks | Female | Brass | Serrated Termination | 14-16 AWG | Standard | 0.580 14.73mm | Non-Insulated | 0.020 0.51mm | Tin | 0.187 4.75mm | ||||||||||||||||||||||||||||||||||||||||||
| PMV6-5F-L | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | 26.416mm | 9.652mm | Yellow | 9.65mm | 4 Weeks | 99.790321g | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 10-12 AWG | 6 mm2 | 12 AWG | 10 AWG | Standard | 1.040 26.42mm | FEMALE | Insulated | 0.240 (6.10mm) | Vinyl | M5 Stud | 0.380 9.65mm | 0.210 (5.33mm) | ||||||||||||||||||||||||||
| LCDX2/0-56DH-X | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Lug® | Free Hanging | Free Hanging (In-Line), 45° Angle | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2011 | 68.1mm | Black | 24.4mm | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 2/0 AWG | Rectangular Tongue | Non-Insulated | 0.130 3.30mm | Electro-Tin | 5/16 Stud | 0.960 24.38mm | 0.640 (16.26mm) | 0.510 (12.95mm) | Two Stud Holes | 0.340 (8.64mm) | |||||||||||||||||||||||||||||||
| EDV10-250FIB-Q | Panduit Corp | $0.35 |
Min: 1 Mult: 1 |
download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | Yellow | 6 Weeks | Female | Brass | 10-12 AWG | Standard | 0.960 24.38mm | Fully Insulated | 0.204 (5.18mm) | 0.032 0.81mm | Tin | 0.250 6.35mm | 0.260 6.60mm | ||||||||||||||||||||||||||||||||||||||||
| PV18-6LFX-MY | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2006 | /files/panduit-pv186lfxmy-datasheets-3890.pdf | 24.13mm | Red | 6.86mm | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | Brazed Seam, Serrated Termination | FORK TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Spring, Snap | 0.950 24.13mm | Insulated | 0.170 (4.32mm) | Vinyl | 6 Stud | 0.270 6.86mm | 0.150 (3.81mm) | |||||||||||||||||||||||||||||
| LCD3/0-14AH-X | Panduit Corp |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 4 Weeks | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| EDNF14-188FIB-Q | Panduit Corp | $0.47 |
Min: 1 Mult: 1 |
download | StrongHold™ | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | https://pdf.utmel.com/r/datasheets/panduitcorp-ednf18187mbq-datasheets-2523.pdf | Blue | 6 Weeks | Female | Brass | 14-16 AWG | Standard | 0.780 19.81mm | Fully Insulated | 0.160 (4.06mm) | 0.020 0.51mm | Tin | 0.187 4.75mm | ||||||||||||||||||||||||||||||||||||||||
| PN10-10LF-2K | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Reel | Not Applicable | Crimp | ROHS3 Compliant | 2007 | https://pdf.utmel.com/r/datasheets/panduit-pn1010lf2k-datasheets-4195.pdf | 26.67mm | Yellow | 8.64mm | 4 Weeks | yes | EAR99 | Copper | Tin | No | 8536.90.40.00 | Serrated Termination | FORK TERMINAL | 10-12 AWG | 6 mm2 | 12 AWG | 10 AWG | Spring, Snap | 1.050 26.67mm | FEMALE | Insulated | 0.130 ~ 0.225 (3.30mm ~ 5.72mm) | Polyamide (PA), Nylon | 10 Stud | 0.340 8.64mm | 0.190 (4.83mm) | ||||||||||||||||||||||||||
| LCC4/0-12-B-X | Panduit Corp |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 4 Weeks | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DVF14-188-M | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2005 | 19.304mm | 5.84mm | Blue | 5.8mm | 4 Weeks | Female | Brass | Tin | No | Copper | Vinyl | PUSH-ON TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Standard | 0.760 19.30mm | Non-Mating End Insulated | 0.162 (4.11mm) | 0.020 0.51mm | 0.187 4.75mm | |||||||||||||||||||||||||||||||
| PV14-6LF-E | Panduit Corp | $0.81 |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2009 | 22.86mm | Blue | 4 Weeks | Copper | Tin | No | Brazed Seam, Serrated Termination | 14-16 AWG | 16 AWG | 14 AWG | Spring, Snap | 0.900 22.86mm | Insulated | 0.170 (4.32mm) | Tin | Vinyl | 6 Stud | 0.250 6.35mm | 0.140 (3.56mm) | ||||||||||||||||||||||||||||||||
| LCCXN2-14AF-E | Panduit Corp |
Min: 1 Mult: 1 |
download | Not Applicable | ROHS3 Compliant | 4 Weeks | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| DNF18-250FIM-L | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 22.86mm | 10.7mm | Red | Nylon | 4 Weeks | 61.23497g | No SVHC | Male | Straight | Brass | Nickel | 22 AWG | Serrated Termination | Nylon | 18-22 AWG | 22 AWG | 18 AWG | Standard | 0.900 22.86mm | Brass | Fully Insulated | 0.133 (3.38mm) | 0.032 0.81mm | Nickel | 0.250 6.35mm | |||||||||||||||||||||||||||
| PNF14-6LFW-C | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2001 | https://pdf.utmel.com/r/datasheets/panduitcorp-pnf1410lfm-datasheets-2887.pdf | 21.336mm | 7.37mm | Blue | 7.37mm | 4 Weeks | EAR99 | Copper | Tin | No | 8536.90.40.00 | Serrated Termination | FORK TERMINAL | 14-16 AWG | 16 AWG | 14 AWG | Spring, Snap | 0.840 21.34mm | FEMALE | Insulated | 0.162 (4.11mm) | Polyamide (PA), Nylon | 6 Stud | 0.290 7.37mm | 0.140 (3.56mm) | |||||||||||||||||||||||||||
| LCC250-12D-X | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Lug® | Free Hanging | Free Hanging (In-Line) | Bulk | Not Applicable | Crimp, Barrel | ROHS3 Compliant | 2011 | 109.728mm | Yellow | 29.7mm | 4 Weeks | EAR99 | Copper | No | 8536.90.40.00 | WIRE TERMINAL | Tin | 250MCM (kcmil) | 126.6 mm2 | Rectangular Tongue | 4.320 109.73mm | FEMALE | Non-Insulated | 0.140 3.56mm | Electro-Tin | 1/2 Stud | 1.170 29.72mm | 0.770 (19.56mm) | 0.630 (16.00mm) | Two Stud Holes | 0.530 (13.46mm) | ||||||||||||||||||||||||||||
| DR18-250-C | Panduit Corp |
Min: 1 Mult: 1 |
download | Pan-Term® | Free Hanging | Free Hanging (In-Line), Right Angle | Bulk | Not Applicable | Crimp | ROHS3 Compliant | 2011 | 14.5mm | 13.7mm | 4 Weeks | Female | EAR99 | Brass | Tin | 8536.90.40.00 | PUSH-ON TERMINAL | 18-22 AWG | 22 AWG | 18 AWG | Angled - 90°, Flag | Non-Insulated | 0.032 0.81mm | 0.250 6.35mm |
Please send RFQ , we will respond immediately.