NorComp(4494)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Type Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination RoHS Status Published Datasheet Current Rating Package / Case Length Height Width Color Lead Free Material Factory Lead Time Ratings REACH SVHC Number of Pins Accessory Type Pbfree Code Connector Type Number of Positions Gender MIL Conformance DIN Conformance IEC Conformance Filter Feature Mixed Contacts Option Number of Contacts Mating Information Contact Gender Empty Shell Housing Color Contact Finish - Mating Number of Ports Flammability Rating ECCN Code Contact Material Contact Plating Housing Material Total Number of Contacts Reach Compliance Code Ingress Protection HTS Code Dielectric Material JESD-609 Code Feature Pitch Body Material Connector Type A Connector Type B Insulation Material Contact Form Termination Type Gender Type A Number of Rows Wire Gauge Wire Gauge (Max) Wire Gauge (Min) Current Rating (Amps) Includes Insulation Shell Material Contact Finish Termination Plating Contact Finish Shell Finish UL Flammability Code Number of Power Positions Contact Finish Thickness Material Flammability Rating Convert From (Adapter End) Convert To (Adapter End) Connector Style Contact Type Flange Feature Shell Size, Connector Layout Shell Material, Finish Backset Spacing Contact Termination Note Termination Finish
180-062-202L021 180-062-202L021 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging, Panel Panel Mount -50°C~100°C Tray 1 (Unlimited) Solder Cup ROHS3 Compliant 2008 /files/norcompinc-180026203l021-datasheets-3207.pdf 5A 14 Weeks yes Receptacle, Female Sockets 62 Female NO NO NO NO NO GENERAL PURPOSE NO Brass PBT 62 Polybutylene Terephthalate (PBT) Shielded 3 Gold TIN 94V-0 Flash UL94 V-0 D-Sub, High Density Signal Cable Side (4-40) 4 DC C High Density Steel, Tin Plated
180-M26-203L011 180-M26-203L011 NorComp
RFQ

Min: 1

Mult: 1

download 180-M, M Series Free Hanging, Panel Panel Mount -55°C~125°C Tray 1 (Unlimited) Solder Cup ROHS3 Compliant 2008 /files/norcompinc-180m15203l001-datasheets-6496.pdf 5A Black 14 Weeks Receptacle, Female Sockets 26 Male Copper Alloy PBT Polybutylene Terephthalate (PBT), Glass Filled Shielded 2.29mm Machined 3 24-28 AWG 3A Brass Nickel Gold Flash UL94 V-0 D-Sub, High Density Signal Cable Side (4-40) 2 DA A High Density Steel, Nickel Plated
189-037-413R451 189-037-413R451 NorComp
RFQ

Min: 1

Mult: 1

download 189 Edge, Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray Solder ROHS3 Compliant 2010 /files/norcompinc-189009413r451-datasheets-5978.pdf 5A Black 14 Weeks Plug, Male Pins; Receptacle, Female Sockets 37, 37 Male to Female 37 2 Brass Nylon Polyamide (PA9T), Nylon 9T e4 Grounding Indents, Shielded Stamped 2, 2 Steel Nickel Gold Flash UL94 V-0 D-Sub - Stacked Signal Housing/Shell (4-40) 4 DC C ; 4 DC C Steel, Nickel Plated 0.318 (8.08mm)
172-050-102R031 172-050-102R031 NorComp
RFQ

Min: 1

Mult: 1

download 172, M Series Free Hanging, Panel Panel Mount -50°C~100°C Tray Not Applicable Solder Cup ROHS3 Compliant 2005 /files/norcompinc-172009102r001-datasheets-8579.pdf 5A 67mm 9.93mm 15.4mm Beige Lead Free 14 Weeks yes Plug, Male Pins 50 Male NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 EAR99 Brass PBT 50 Polybutylene Terephthalate (PBT), Glass Filled Grounding Indents Machined 3 20-26 AWG Gold TIN 94V-0 Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 5 DD D Steel, Tin Plated
172-050-202R031 172-050-202R031 NorComp
RFQ

Min: 1

Mult: 1

download 172, M Series Free Hanging, Panel Panel Mount -50°C~100°C Tray Not Applicable Solder Cup ROHS3 Compliant 2005 /files/norcompinc-172009202r011-datasheets-5641.pdf 5A 67mm 10.2mm 15.4mm Beige Lead Free 14 Weeks yes Receptacle, Female Sockets 50 Female UL94 V-0 Brass PBT unknown Polybutylene Terephthalate (PBT), Glass Filled Machined 3 20-26 AWG Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 5 DD D Steel, Tin Plated
172-037-242R011 172-037-242R011 NorComp
RFQ

Min: 1

Mult: 1

download 172, M Series Through Hole Panel Mount, Through Hole -50°C~100°C Tray Not Applicable Wire Wrap ROHS3 Compliant 2005 /files/norcompinc-172009242r011-datasheets-6223.pdf 5A 69.4mm 10.1mm 12.6mm Beige Lead Free 14 Weeks yes Receptacle, Female Sockets 37 Female NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 EAR99 Brass PBT 37 8536.69.40.30 Polybutylene Terephthalate (PBT), Polyester Machined 2 Tin Gold TIN 94V-0 Flash UL94 V-0 D-Sub Signal Board Side (4-40) 4 DC C Steel, Tin Plated
774-E25-213R141 774-E25-213R141 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 774-E Through Hole Panel Mount, Through Hole, Right Angle -50°C~100°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12.6mm White Lead Free 14 Weeks Dust Tight, IP67, Waterproof yes Receptacle, Female Sockets 25 Female Brass Nylon IP67 - Dust Tight, Waterproof Polyamide (PA6T), Nylon 6T Mounting Brackets 2.54mm Machined 2 Non-Insulated Steel Nickel Gold Flash UL94 V-0 D-Sub Signal Mating Side, Female Screwlock (4-40) 3 DB B Steel, Nickel Plated 0.370 (9.40mm)
197-078-213L031 197-078-213L031 NorComp
RFQ

Min: 1

Mult: 1

download 197, M Series Through Hole Panel Mount, Through Hole -55°C~125°C Tray Not Applicable Solder ROHS3 Compliant 2005 /files/norcompinc-197015213l551-datasheets-5570.pdf 2A 66.9mm 13.1mm 12.5mm Black Lead Free 14 Weeks Receptacle, Female Sockets 78 Female UL94 V-0 Phosphor Bronze PBT Polybutylene Terephthalate (PBT) e3 Shielded Polyester Machined 4 Insulated Steel Nickel Gold Flash UL94 V-0 D-Sub, High Density Signal Mating Side, Female Screwlock (4-40) 5 DD D High Density Steel, Nickel Plated
172-037-283L031 172-037-283L031 NorComp
RFQ

Min: 1

Mult: 1

download 172, M Series Through Hole Panel Mount, Through Hole -50°C~125°C Tray Not Applicable Solder ROHS3 Compliant 2005 /files/norcompinc-172009283l021-datasheets-8069.pdf 5A 69.4mm 12.6mm Black Lead Free 14 Weeks yes Receptacle, Female Sockets 37 Female UL94 V-0 Brass PBT Polybutylene Terephthalate (PBT) Machined 2 Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 4 DC C Steel, Nickel Plated
684S21WA4PL461 684S21WA4PL461 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 684S Free Hanging Board Edge, Through Hole, Right Angle -55°C~125°C Tray 1 (Unlimited) Solder ROHS3 Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 14 Weeks Dust Tight, IP67, Waterproof No SVHC yes Plug, Male Pins 21 (17 + 4 Power) Male 21 Copper Alloy PBT IP67 - Dust Tight, Waterproof Polybutylene Terephthalate (PBT), Glass Filled Board Lock, Grounding Indents, Mounting Brackets Steel 2 5A 40A Insulated Nickel Gold 4 Flash UL94 V-0 D-Sub, Combo Signal and Power Housing/Shell (4-40) 4 DC C - 21WA4 Steel, Nickel Plated 0.402 (10.21mm)
182-015-113R431 182-015-113R431 NorComp
RFQ

Min: 1

Mult: 1

download 182 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray Solder ROHS3 Compliant 2008 /files/norcompinc-182037113r161-datasheets-3788.pdf 5A 39.1mm 12.5mm 24.9mm Black Lead Free 12 Weeks yes Plug, Male Pins 15 Male NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 Brass Nylon 15 Polyamide (PA9T), Nylon 9T Grounding Indents 2 Gold 94V-0 Flash UL94 V-0 D-Sub Signal Housing/Shell (Unthreaded) 2 DA A Steel, Nickel Plated 0.318 (8.08mm)
191-037-113L591 191-037-113L591 NorComp
RFQ

Min: 1

Mult: 1

download 191 Through Hole Panel Mount, Through Hole -55°C~125°C Tray Not Applicable Solder ROHS3 Compliant 2009 /files/norcompinc-191009113l551-datasheets-8724.pdf 5A 69.3mm 12.1mm 12.5mm Black Lead Free 12 Weeks yes Plug, Male Pins 37 NO NO NO NO NO GENERAL PURPOSE NO UL94 V-0 EAR99 Brass Polyester 37 8536.69.40.30 Polyester Thermoplastic e3 Grounding Indents, Shielded 2 Gold 94V-0 Flash UL94 V-0 D-Sub Signal Mating Side, Female Screwlock (4-40) 4 DC C Steel, Nickel Plated
683-009-113R171 683-009-113R171 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 683 Through Hole Panel Mount, Through Hole, Right Angle -55°C~105°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 9 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Ground Strap, Grounding Indents 2 Gold Flash UL94 V-0 D-Sub Signal Housing/Shell (4-40) 1 DE E Steel, Nickel Plated 0.590 (14.99mm)
671-009-113R031 671-009-113R031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 9 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Mating Side (4-40) 1 DE E Steel, Nickel Plated
671-015-113R051 671-015-113R051 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 671 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A Black 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 15 Brass Nylon IP66 - Dust Tight, Water Resistant Polyamide (PA9T), Nylon 9T Board Lock, Grounding Indents Stamped 2 Gold Flash UL94 V-0 D-Sub Signal Board Side (4-40) 2 DA A Steel, Nickel Plated
680-026-113R031 680-026-113R031 NorComp
RFQ

Min: 1

Mult: 1

download Seal-D 680 Through Hole Panel Mount, Through Hole -50°C~100°C Tray 1 (Unlimited) Solder RoHS Compliant 2012 /files/norcompinc-780m44213r001-datasheets-2740.pdf 5A 12 Weeks Dust Tight, IP66, Water Resistant yes Plug, Male Pins 26 Brass PBT IP66 - Dust Tight, Water Resistant Polybutylene Terephthalate (PBT) Grounding Indents Stamped 3 Gold Flash UL94 V-0 D-Sub, High Density Signal Mating Side (4-40) 2 DA A High Density Steel, Nickel Plated
RJADK09S7080811 RJADK09S7080811 NorComp
RFQ

Min: 1

Mult: 1

download RJADK ROHS3 Compliant 2007 /files/norcompinc-rjadk09s7080811-datasheets-8305.pdf Black 14 Weeks No SVHC 9 D-Sub, Standard RJ45 Female D-Sub, 9 Pin Female Modular, Female Jack, 8p8c (RJ45)
110-036-203-001 110-036-203-001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI Centronics, 110- Free Hanging Free Hanging (In-Line) Not Applicable Solder Cup Non-RoHS Compliant 2002 /files/norcompinc-110014203001-datasheets-0019.pdf Contains Lead Receptacle 36 Female 36 UL94 V-0 Gold Plastic Assembly Hardware, Backshell, Bail Lock, Strain Relief 2 Gold Flash Outer Shroud Contacts Housing/Shell (Unthreaded)
111-036-113-001 111-036-113-001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Through Hole Through Hole Not Applicable Solder Non-RoHS Compliant 2002 /files/norcompinc-111024113001-datasheets-0120.pdf Contains Lead Plug 36 Male 36 Blue UL94 V-0 Gold Plastic 2 Gold Flash Center Strip Contacts
111-014-203L001 111-014-203L001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Free Hanging Free Hanging (In-Line) Not Applicable Solder Cup ROHS3 Compliant 2012 /files/norcompinc-111024203l001-datasheets-2857.pdf 5A Lead Free 14 Weeks No SVHC yes Receptacle 14 Blue UL94 V-0 Bronze Plastic Bail Lock 2 Gold Flash Outer Shroud Contacts Housing/Shell (Unthreaded)
111-024-113L001 111-024-113L001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI 111 Through Hole Through Hole Not Applicable Solder ROHS3 Compliant 2014 /files/norcompinc-111050113l001-datasheets-4109.pdf 5A Lead Free 14 Weeks No SVHC yes Plug 24 Male Blue UL94 V-0 Bronze Plastic 2 Gold Flash Center Strip Contacts Housing/Shell (Unthreaded)
110-050-203L001 110-050-203L001 NorComp
RFQ

Min: 1

Mult: 1

download SCSI Centronics, 110- Free Hanging Free Hanging (In-Line) Not Applicable Solder Cup RoHS Compliant 2008 /files/norcompinc-110014203l001-datasheets-2071.pdf 5A Lead Free No SVHC yes Receptacle 50 NO NO NO NO NO GENERAL PURPOSE MULTIPLE MATING PARTS AVAILABLE FEMALE NO UL94 V-0 EAR99 Copper Plastic 50 unknown 8536.69.40.30 Backshell, Bail Lock, Strain Relief 2 STEEL Gold NICKEL 94V-0 Flash Outer Shroud Contacts Housing/Shell (Unthreaded)
822B-DC 822B-DC NorComp
RFQ

Min: 1

Mult: 1

download VULCON™. 1 (Unlimited) ROHS3 Compliant 2016 /files/norcompinc-822bdc-datasheets-6819.pdf Silver Brass 14 Weeks Cap (Cover), Dust Dust Tight, Lanyard, Water Resistant
GCHDLPF15F15F GCHDLPF15F15F NorComp
RFQ

Min: 1

Mult: 1

download GCLP Free Hanging Panel Mount -55°C~105°C 1 (Unlimited) ROHS3 Compliant 2008 /files/norcompinc-gchdlpf15f15f-datasheets-5272.pdf 14 Weeks No SVHC 15 Yellow BRASS e4 3 3A 5 pcs - 1 Connector, 2 Jack Screws, 2 Nuts Gold Flash UL94 V-0 D-Sub, 15 HD, Female D-Sub, 15 HD, Female Gender Changer Steel, Tin Plated
GCHDLP26M26M GCHDLP26M26M NorComp
RFQ

Min: 1

Mult: 1

download GCLP Free Hanging Panel Mount -55°C~105°C Not Applicable ROHS3 Compliant 2011 /files/norcompinc-gchdlp26m26m-datasheets-5635.pdf 14 Weeks No SVHC 26 Yellow Grounding Indents D-Sub Male 3 3A 3 pcs - 1 Connector, 2 Jack Screws Gold Flash UL94 V-0 D-Sub, 26 HD, Male D-Sub, 26 HD, Male Gender Changer Steel, Tin Plated
180-001-170L001 180-001-170L001 NorComp
RFQ

Min: 1

Mult: 1

download Signal 180 Tape & Reel (TR) Not Applicable ROHS3 Compliant 2011 /files/norcompinc-180001170l001-datasheets-8503.pdf Lead Free 16 Weeks yes Male Pin Male Brass High Density (HD), Insulation Support Stamped 24-26 AWG 26 AWG 24 AWG Gold 10.0μin 0.25μm Male Pin Crimp Nickel
170-102-170L003 170-102-170L003 NorComp
RFQ

Min: 1

Mult: 1

download Signal 170 Bulk Not Applicable ROHS3 Compliant 2012 /files/norcompinc-170102170l001-datasheets-9906.pdf 14 Weeks yes Socket Brass Stamped 24-28 AWG 28 AWG 24 AWG Gold 30.0μin 0.76μm Female Socket Crimp
180-015-172L000 180-015-172L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) Crimp ROHS3 Compliant 2008 /files/norcompinc-180078172l000-datasheets-1445.pdf 5A 12.6mm 14 Weeks Plug for Male Contacts 15 Male Shielded 3 Insulated Steel Tin D-Sub, High Density Signal Housing/Shell (Unthreaded) 1 DE E High Density Steel, Tin Plated Contacts Not Included
180-015-273L000 180-015-273L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray Not Applicable Crimp ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf 2A 015 30.8mm 12.6mm Lead Free 14 Weeks No SVHC yes Receptacle for Female Contacts 15 Receptacle NO NO NO NO NO GENERAL PURPOSE YES GOLD OVER NICKEL EAR99 BRASS 15 e4 Steel GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 3 Tin 94V-0 D-Sub, High Density Signal Housing/Shell (Unthreaded) 1 DE E High Density Steel, Nickel Plated Contacts Not Included
180-078-272L000 180-078-272L000 NorComp
RFQ

Min: 1

Mult: 1

download 180 Free Hanging Free Hanging (In-Line) -50°C~100°C Tray 1 (Unlimited) ROHS3 Compliant 2008 /files/norcompinc-180078273l020-datasheets-1428.pdf Lead Free 14 Weeks yes Receptacle for Female Contacts 78 Female NO NO NO NO NO GENERAL PURPOSE YES GOLD OVER NICKEL EAR99 BRASS 78 e4 Shielded GLASS FILLED POLYBUTYLENE TEREPHTHALATE/NYLON66 CRIMP 4 Gold (Au) - with Nickel (Ni) barrier TIN D-Sub, High Density Signal Housing/Shell (Unthreaded) 5 DD D High Density Steel, Tin Plated Contacts Not Included

In Stock

Please send RFQ , we will respond immediately.