Cantherm(1408)

Compare Image Name Manufacturer Pricing(USD) Quantity Weight(Kg) Size(LxWxH) Part Status Type Series Mount Mounting Type Operating Temperature Packaging Moisture Sensitivity Level (MSL) Termination Max Operating Temperature Min Operating Temperature RoHS Status Published Datasheet Diameter Package / Case Lead Free Factory Lead Time Resistance Lead Length Tolerance Case Code (Metric) Case Code (Imperial) Max Power Dissipation Termination Style Circuit Throw Configuration Power - Max Resistance Tolerance Resistance @ 25°C Resistance in Ω @ 25°C B Value Tolerance B25/50 Switching Cycles Current Rating - AC Switching Temperature Reset Temperature Current Rating - DC
CMFA3950224JNT CMFA3950224JNT Cantherm
RFQ

Min: 1

Mult: 1

download CMF Surface Mount Surface Mount -40°C~125°C Tape & Reel (TR) 1 (Unlimited) 125°C -40°C ROHS3 Compliant 2009 /files/cantherm-cmfa3950104jnt-datasheets-7576.pdf 0603 (1608 Metric) 9 Weeks 5% 1608 0603 100mW 100mW ±5% 220k 3950K
CMFB4000104JNT CMFB4000104JNT Cantherm
RFQ

Min: 1

Mult: 1

download CMF Surface Mount Surface Mount -40°C~125°C Tape & Reel (TR) 1 (Unlimited) ROHS3 Compliant 2009 /files/cantherm-cmfa3950104jnt-datasheets-7576.pdf 0805 (2012 Metric) 10 Weeks 5% 2012 0805 200mW ±5% 100k 4000K
YGM1 C513 YGM1 C513 Cantherm
RFQ

Min: 1

Mult: 1

download YGM PCB, Through Hole -20°C~60°C Bulk 1 (Unlimited) ROHS3 Compliant 2002 /files/cantherm-ygm1c508-datasheets-0415.pdf Radial 7 Weeks 690mW ±10% 250Ohm
CMFB3435103JNT CMFB3435103JNT Cantherm
RFQ

Min: 1

Mult: 1

download CMF Surface Mount Surface Mount -40°C~125°C Tape & Reel (TR) 1 (Unlimited) 125°C -40°C ROHS3 Compliant 2009 /files/cantherm-cmfa3950104jnt-datasheets-7576.pdf 0805 (2012 Metric) 9 Weeks 5% 200mW 200mW ±5% 10k 3435K
MF11-0100010 MF11-0100010 Cantherm
RFQ

Min: 1

Mult: 1

download MF11 PCB, Through Hole Through Hole -55°C~125°C Bulk Not Applicable 125°C -55°C ROHS3 Compliant /files/cantherm-mf110002010-datasheets-0680.pdf Disc, 6.5mm Dia x 5.0mm W Lead Free 9 Weeks 1kOhm 10% 500mW 500mW ±10% 1k ±5% 3600K
CMFA3950473FNT CMFA3950473FNT Cantherm
RFQ

Min: 1

Mult: 1

download CMF Surface Mount Surface Mount -40°C~125°C Tape & Reel (TR) 1 (Unlimited) 125°C -40°C ROHS3 Compliant 2009 /files/cantherm-cmfa3950104jnt-datasheets-7576.pdf 0603 (1608 Metric) 9 Weeks 1% 100mW 100mW ±1% 47k ±1% 3950K
MF11-0030005 MF11-0030005 Cantherm
RFQ

Min: 1

Mult: 1

download MF11 PCB, Through Hole Through Hole -55°C~125°C Bulk Not Applicable 125°C -55°C ROHS3 Compliant 2006 /files/cantherm-mf110002010-datasheets-0680.pdf Disc, 6.5mm Dia x 5.0mm W 8 Weeks 300Ohm 5% 500mW 500mW ±5% 300 ±5% 3600K
CWF1B104G3950 CWF1B104G3950 Cantherm
RFQ

Min: 1

Mult: 1

download CWF1 Free Hanging Free Hanging -55°C~125°C Bulk 1 (Unlimited) 125°C -55°C ROHS3 Compliant 2006 /files/cantherm-cwf1b103g3380-datasheets-5980.pdf 5mm Bead Lead Free 9 Weeks 100kOhm 3.28' 1.00m 2% ±2% 100k ±2% 3950K
CWF3AA472F3470 CWF3AA472F3470 Cantherm
RFQ

Min: 1

Mult: 1

download CWF3 Free Hanging Free Hanging -55°C~125°C Not Applicable ROHS3 Compliant 2010 /files/cantherm-cwf1b103g3380-datasheets-5980.pdf Cylindrical Probe, Plastic 9 Weeks 7.87 200.00mm 1% ±1% 4.7k ±2% 3470K
MF52C683F3950-G410 MF52C683F3950-G410 Cantherm
RFQ

Min: 1

Mult: 1

download MF52 Through Hole Through Hole -55°C~125°C Bulk Not Applicable ROHS3 Compliant /files/cantherm-mf52a2103j3470-datasheets-5532.pdf Bead 9 Weeks 7.87 200.00mm 1% 50mW ±1% 68k 3950K
MF58504F4300 MF58504F4300 Cantherm
RFQ

Min: 1

Mult: 1

download MF58 Through Hole Through Hole -55°C~200°C Bulk Not Applicable ROHS3 Compliant 2006 /files/cantherm-mf58104f3950-datasheets-5255.pdf Bead, Glass 9 Weeks 1% 50mW ±1% 470k 4300K
MF52C1153F3470 MF52C1153F3470 Cantherm
RFQ

Min: 1

Mult: 1

download MF52 Through Hole Through Hole -55°C~125°C Bulk Not Applicable ROHS3 Compliant 2010 /files/cantherm-mf52a2103j3470-datasheets-5532.pdf Bead 9 Weeks 7.87 200.00mm 1% 50mW ±1% 15k 3470K
MF51B223F3470 MF51B223F3470 Cantherm
RFQ

Min: 1

Mult: 1

download MF51B Through Hole Through Hole -20°C~250°C Bulk Not Applicable RoHS Compliant 2006 /files/cantherm-mf58104f3950-datasheets-5255.pdf Bead, Glass 1% ±1% 22k
MF51B104F3950 MF51B104F3950 Cantherm
RFQ

Min: 1

Mult: 1

download MF51B Through Hole Through Hole -20°C~250°C Bulk Not Applicable 250°C -20°C RoHS Compliant 2006 /files/cantherm-mf58104f3950-datasheets-5255.pdf Bead, Glass 1% ±1% 100k
B12A12505AEDA0GE B12A12505AEDA0GE Cantherm
RFQ

Min: 1

Mult: 1

download B12 Through Hole Through Hole Not Applicable ROHS3 Compliant /files/cantherm-b12a11525aefa0ge-datasheets-6629.pdf Radial 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 1K 6A 250V 257°F 125°C 203°F 95°C
F20A120051ZA0060 F20A120051ZA0060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 7K 1.6A 250V 248°F 120°C 194°F 90°C
F20A075051ZA0060 F20A075051ZA0060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 7K 1.6A 250V 167°F 75°C 113°F 45°C
CS702015Y CS702015Y Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant 2010 /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NO 100K 10A 250V 15A 125V 68°F 20°C 10A 24V 15A 12V
F20A115053600060 F20A115053600060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 7K 1.6A 250V 240°F 115°C 185°F 85°C
F20B15005DCFB06E F20B15005DCFB06E Cantherm
RFQ

Min: 1

Mult: 1

download Mechanical F20 Through Hole Through Hole Not Applicable Wire Leads ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf Housed Sensor 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NO SPST 7K 1.6A 250V 302°F 150°C 248°F 120°C
B12B06005AEDA0GE B12B06005AEDA0GE Cantherm
RFQ

Min: 1

Mult: 1

download B12 Through Hole Through Hole Not Applicable Wire Leads ROHS3 Compliant 2009 /files/cantherm-b12a11525aefa0ge-datasheets-6629.pdf Radial 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NO SPST 5K 1.6A 250V 140°F 60°C 86°F 30°C
F20A08505ACPA06E F20A08505ACPA06E Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 7K 1.6A 250V 185°F 85°C 131°F 55°C
CS709025Z CS709025Z Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant 2010 /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NC 100K 10A 250V 15A 125V 194°F 90°C 10A 24V 15A 12V
B12A06005AEDA0GE B12A06005AEDA0GE Cantherm
RFQ

Min: 1

Mult: 1

download B12 Through Hole Through Hole Not Applicable ROHS3 Compliant /files/cantherm-b12a11525aefa0ge-datasheets-6629.pdf Radial 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NC 1K 6A 250V 140°F 60°C 86°F 30°C
CS703525Y CS703525Y Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant 2010 /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NC 100K 10A 250V 15A 125V 95°F 35°C 10A 24V 15A 12V
CS707525Y CS707525Y Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount 1 (Unlimited) ROHS3 Compliant /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NC 100K 10A 250V 15A 125V 167°F 75°C 10A 24V 15A 12V
CS710015Y CS710015Y Cantherm
RFQ

Min: 1

Mult: 1

download R53 Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant 2010 /files/cantherm-cs706525z-datasheets-8425.pdf Cylinder with Mounting Flange 11 Weeks ±9°F ±5°C Quick Connect SPST-NO 100K 10A 250V 15A 125V 212°F 100°C 10A 24V 15A 12V
F20B070053600060 F20B070053600060 Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable ROHS3 Compliant 2009 /files/cantherm-f20b090053600060-datasheets-6670.pdf 2-SIP, Potted 5 Weeks ±9°F ±5°C Wire Leads - 4 (101.6mm) SPST-NO 7K 1.6A 250V 158°F 70°C 104°F 40°C
A1007005 A1007005 Cantherm
RFQ

Min: 1

Mult: 1

download Mechanical A10V Chassis Mount Chassis Mount 1 (Unlimited) ROHS3 Compliant 2009 /files/cantherm-a1009005-datasheets-8629.pdf Module 5 Weeks ±9°F ±5°C User Defined SPST-NC SPST 6K 2.5A 250V 158°F 70°C
F20A15505ACFA06E F20A15505ACFA06E Cantherm
RFQ

Min: 1

Mult: 1

download F20 Through Hole Through Hole Not Applicable RoHS Compliant /files/cantherm-f20a16005acfa06e-datasheets-3512.pdf Potted - Wire Leads ±9°F ±5°C Wire Leads - 6 (152.4mm) SPST-NC 7K 1.6A 250V 311°F 155°C 257°F 125°C

In Stock

Please send RFQ , we will respond immediately.